Comparisons of multiple automated anatomy-based image-guidance methods for patient setup before head/neck external beam radiotherapy

被引:0
作者
Dogan, Nesrin [1 ]
Song, Shiyu [1 ]
Saleh, Habeeb [1 ]
Wu, Jian [1 ]
Murphy, Martin J. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Med Ctr, Richmond, VA 23298 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2011年 / 12卷 / 01期
关键词
image registration; image-guided setup; setup uncertainty; registration error; head/neck radiotherapy; COMPUTED-TOMOGRAPHY; CT; REGISTRATION; TOMOTHERAPY;
D O I
10.1120/jacmp.v12i1.3337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose was to assess the variability in automated translational head/neck setup corrections computed from several different imaging modalities and rigid registration methods using patient anatomy. Shifts were calculated using three commercial and one in-house automated rigid registration methods for nine head/neck patients who were imaged with three different image-guidance systems. The mean difference between the daily isocenter shifts determined by the four methods ranged from 2.8 to 12.5 mm for all of the test cases. These differences are much greater than the variability observed for a rigid imaging phantom. Image-guided setup procedures have an uncertainty that depends on the imaging modality, the registration algorithm, the image resolution and the image content. In the absence of an absolute ground truth, the variation in the shifts calculated by several different methods provides a useful estimate of that uncertainty.
引用
收藏
页码:76 / 85
页数:10
相关论文
共 9 条
[1]   Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: An intra- and interobserver study [J].
Court, LE ;
Dong, L ;
Taylor, N ;
Ballo, M ;
Kitamura, K ;
Lee, AK ;
O'Daniel, J ;
White, RA ;
Cheung, R ;
Kuban, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02) :412-418
[2]   Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[3]   Comparison of 2D radiographic images and 3D cone beam computed tomography for positioning head-and-neck radiotherapy patients [J].
Li, Heng ;
Zhu, X. Ronald ;
Zhang, Lifei ;
Dong, Lei ;
Tung, Sam ;
Ahamad, Anesa ;
Chao, K. S. Clifford ;
Morrison, William H. ;
Rosenthal, David I. ;
Schwartz, David L. ;
Mohan, Radhe ;
Garden, Adam S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (03) :916-925
[4]   Image-guided patient positioning: If one cannot correct for rotational offsets in external-beam radiotherapy setup, how should rotational offsets be managed? [J].
Murphy, Martin J. .
MEDICAL PHYSICS, 2007, 34 (06) :1880-1883
[5]   A comparison of similarity measures for use in 2-D-3-D medical image registration [J].
Penney, GP ;
Weese, J ;
Little, JA ;
Desmedt, P ;
Hill, DLG ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (04) :586-595
[6]   Megavoltage CT on a tomotherapy system [J].
Ruchala, KJ ;
Olivera, GH ;
Schloesser, EA ;
Mackie, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10) :2597-2621
[7]  
Wong JR, 2001, PHYS MEDICA, V17, P271
[8]   Image registration of a moving target phantom with helical tomotherapy: effect of the CT acquisition technique and action level proposal [J].
Woodford, Curtis ;
Yartsev, Slav ;
Van Dyk, Jake .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (18) :5093-5106
[9]   Assessing the intrinsic precision of 3D/3D rigid image registration results for patient setup in the absence of a ground truth [J].
Wu, Jian ;
Murphy, Martin J. .
MEDICAL PHYSICS, 2010, 37 (06) :2501-2508