Semi-automated scar detection in delayed enhanced cardiac magnetic resonance images

被引:3
作者
Morisi, Rita [1 ,2 ]
Donini, Bruno [2 ]
Lanconelli, Nico [2 ]
Rosengarden, James [3 ]
Morgan, John [3 ]
Harden, Stephen [3 ]
Curzen, Nick [3 ,4 ]
机构
[1] IMT Inst Adv Studies, I-55100 Lucca, Italy
[2] Univ Bologna, Alma Mater Studiorum, Dipartimento Fis & Astron, I-40127 Bologna, Italy
[3] Univ Hosp Southampton NHS Fdn Trust, Southampton SO16 6YD, Hants, England
[4] Univ Southampton, Fac Med, Southampton SO16 6YD, Hants, England
来源
INTERNATIONAL JOURNAL OF MODERN PHYSICS C | 2015年 / 26卷 / 01期
关键词
Image processing; computer aided detection; support vector machine; NONISCHEMIC CARDIOMYOPATHY; VENTRICULAR-TACHYCARDIA; MR-IMAGES; CLASSIFICATION; SEGMENTATION; ARRHYTHMIAS; SUBSTRATE; FEATURES;
D O I
10.1142/S0129183115500114
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Late enhancement cardiac magnetic resonance images (MRI) has the ability to precisely delineate myocardial scars. We present a semi-automated method for detecting scars in cardiac MRI. This model has the potential to improve routine clinical practice since quantification is not currently offered due to time constraints. A first segmentation step was developed for extracting the target regions for potential scar and determining pre-candidate objects. Pattern recognition methods are then applied to the segmented images in order to detect the position of the myocardial scar. The database of late gadolinium enhancement (LE) cardiac MR images consists of 111 blocks of images acquired from 63 patients at the University Hospital Southampton NHS Foundation Trust (UK). At least one scar was present for each patient, and all the scars were manually annotated by an expert. A group of images (around one third of the entire set) was used for training the system which was subsequently tested on all the remaining images. Four different classifiers were trained (Support Vector Machine (SVM), k-nearest neighbor (KNN), Bayesian and feed-forward neural network) and their performance was evaluated by using Free response Receiver Operating Characteristic (FROC) analysis. Feature selection was implemented for analyzing the importance of the various features. The segmentation method proposed allowed the region affected by the scar to be extracted correctly in 96% of the blocks of images. The SVM was shown to be the best classifier for our task, and our system reached an overall sensitivity of 80% with less than 7 false positives per patient. The method we present provides an effective tool for detection of scars on cardiac MRI. This may be of value in clinical practice by permitting routine reporting of scar quantification.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Fully Automated Assessment of Left Ventricular Volumes and Mass from Cardiac Magnetic Resonance Images
    Marino, M.
    Veronesi, F.
    Corsi, C.
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1079 - 1082
  • [42] Semi-automated localization of dermal epidermal junction in optical coherence tomography images of skin
    Taghavikhalilbad, Adeleh
    Adabi, Saba
    Clayton, Anne
    Soltanizadeh, Hadi
    Mehregan, Darius
    Avanaki, Mohammad R. N.
    [J]. APPLIED OPTICS, 2017, 56 (11) : 3116 - 3121
  • [43] A Comprehensive 3-D Framework for Automatic Quantification of Late Gadolinium Enhanced Cardiac Magnetic Resonance Images
    Wei, Dong
    Sun, Ying
    Ong, Sim-Heng
    Chai, Ping
    Teo, Lynette L.
    Low, Adrian F.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) : 1499 - 1508
  • [44] Evaluation of the use of unipolar voltage amplitudes for detection of myocardial scar assessed by cardiac magnetic resonance imaging in heart failure patients
    Nguyen, Uyen Chau
    Maffessanti, Francesco
    Mafi-Rad, Masih
    Conte, Giulio
    Zeemering, Stef
    Regoli, Francois
    Caputo, Maria Luce
    van Stipdonk, Antonius M. W.
    Bekkers, Sebastiaan C. A. M.
    Suerder, Daniel
    Moccetti, Tiziano
    Krause, Rolf
    Prinzen', Frits W.
    Vernooy', Kevin
    Auricchio, Angelo
    [J]. PLOS ONE, 2017, 12 (07):
  • [45] SEMI-AUTOMATED DETECTION OF SURFACE DEGRADATION ON BRIDGES BASED ON A LEVEL SET METHOD
    Masiero, A.
    Guarnieri, A.
    Pirotti, F.
    Vettore, A.
    [J]. ISPRS GEOSPATIAL WEEK 2015, 2015, 40-3 (W3): : 15 - 21
  • [46] Automated lesion detection in dynamic contrast-enhanced magnetic resonance imaging of breast
    Liang, Xi
    Kotagiri, Ramamohanarao
    Frazer, Helen
    Yang, Qing
    [J]. MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [47] New automated Markov–Gibbs random field based framework for myocardial wall viability quantification on agent enhanced cardiac magnetic resonance images
    Ahmed Elnakib
    Garth M. Beache
    Georgy Gimel’farb
    Ayman El-Baz
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1683 - 1698
  • [48] Delayed enhancement on cardiac magnetic resonance imaging is a poor prognostic factor in patients with cardiac sarcoidosis
    Shafee, Mohamed Abdel
    Fukuda, Koji
    Wakayama, Yuji
    Nakano, Makoto
    Kondo, Masateru
    Hasebe, Yuhi
    Kawana, Akiko
    Shimokawa, Hiroaki
    [J]. JOURNAL OF CARDIOLOGY, 2012, 60 (5-6) : 448 - 453
  • [49] Endocardial Border Detection in Cardiac Magnetic Resonance Images Using Level Set Method
    Ammar, Mohammed
    Mahmoudi, Said
    Chikh, Mohammed Amine
    Abbou, Amine
    [J]. JOURNAL OF DIGITAL IMAGING, 2012, 25 (02) : 294 - 306
  • [50] Endocardial Border Detection in Cardiac Magnetic Resonance Images Using Level Set Method
    Mohammed Ammar
    Saïd Mahmoudi
    Mohammed Amine Chikh
    Amine Abbou
    [J]. Journal of Digital Imaging, 2012, 25 : 294 - 306