The Added Value of Computer-aided Detection of Small Pulmonary Nodules and Missed Lung Cancers

被引:31
作者
Cai, Jiali [1 ]
Xu, Dongming [2 ]
Liu, Shiyuan [1 ]
Cham, Matthew D. [2 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Radiol, Shanghai, Peoples R China
[2] Mt Sinai Sch Med, Dept Radiol, 1176 5th Ave, New York, NY 10029 USA
关键词
computer-aided detection; pulmonary nodules; low-dose multidetector computed tomography; missed lung cancers; NEURAL-NETWORK MTANN; RADIOLOGISTS DETECTION; AUTOMATIC DETECTION; CHEST RADIOGRAPHY; CAD-SYSTEM; CT; TOMOGRAPHY; DIAGNOSIS; PERFORMANCE; VARIABILITY;
D O I
10.1097/RTI.0000000000000362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Lung cancer at its earliest stage is typically manifested on computed tomography as a pulmonary nodule, which could be detected by low-dose multidetector computed tomography technology and the use of thinner collimation. Within the last 2 decades, computer-aided detection (CAD) of pulmonary nodules has been developed to meet the increasing demand for lung cancer screening computed tomography with a larger set of images per scan. This review introduced the basic techniques and then summarized the up-to-date applications of CAD systems in clinical and research programs and in the low-dose lung cancer screening trials, especially in the detection of small pulmonary nodules and missed lung cancers. Many studies have already shown that the CAD systems could increase the sensitivity and reduce the false-positive rate in the diagnosis of pulmonary nodules, especially for the small and isolated nodules. Further improvements to the current CAD schemes are needed to detect nodules accurately, particularly for subsolid nodules.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 55 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]   Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening [J].
Arimura, H ;
Katsuragawa, S ;
Suzuki, K ;
Li, F ;
Shiraishi, J ;
Sone, S ;
Doi, K .
ACADEMIC RADIOLOGY, 2004, 11 (06) :617-629
[3]   The Lung Image Database Consortium (LIDC): An evaluation of radiologist variability in the identification of lung nodules on CT scans [J].
Armato, Samuel G., III ;
McNitt-Gray, Michael F. ;
Reeves, Anthony P. ;
Meyer, Charles R. ;
McLennan, Geoffrey ;
Aberle, Denise R. ;
Kazerooni, Ella A. ;
MacMahon, Heber ;
van Beek, Edwin J. R. ;
Yankelevitz, David ;
Hoffman, Eric A. ;
Henschke, Claudia I. ;
Roberts, Rachael Y. ;
Brown, Matthew S. ;
Engelmann, Roger M. ;
Pais, Richard C. ;
Piker, Christopher W. ;
Qing, David ;
Kocherginsky, Masha ;
Croft, Barbara Y. ;
Clarke, Laurence P. .
ACADEMIC RADIOLOGY, 2007, 14 (11) :1409-1421
[4]   Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program [J].
Armato, SG ;
Li, F ;
Giger, ML ;
MacMahon, H ;
Sone, S ;
Doi, K .
RADIOLOGY, 2002, 225 (03) :685-692
[5]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[6]   Computer-aided detection of solid lung nodules on follow-up MDCT screening: Evaluation of detection, tracking, and reading time [J].
Beigelman-Aubrey, Catherine ;
Raffy, Philippe ;
Yang, Wenjie ;
Castellino, Ronald A. ;
Grenier, Philippe A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) :948-955
[7]   A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model [J].
Bellotti, R. ;
De Carlo, F. ;
Gargano, G. ;
Tangaro, S. ;
Cascio, D. ;
Catanzariti, E. ;
Cerello, P. ;
Cheran, S. C. ;
Delogu, P. ;
De Mitri, I. ;
Fulcheri, C. ;
Grosso, D. ;
Retico, A. ;
Squarcia, S. ;
Tommasi, E. ;
Golosio, Bruno .
MEDICAL PHYSICS, 2007, 34 (12) :4901-4910
[8]   Computer-aided diagnosis (CAD) of subsolid nodules: Evaluation of a commercial CAD system [J].
Benzakoun, Joseph ;
Bommart, Sebastien ;
Coste, Joel ;
Chassagnon, Guillaume ;
Lederlin, Mathieu ;
Boussouar, Samia ;
Revel, Marie-Pierre .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) :1728-1734
[9]   Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader [J].
F. Beyer ;
L. Zierott ;
E. M. Fallenberg ;
K. U. Juergens ;
J. Stoeckel ;
W. Heindel ;
D. Wormanns .
European Radiology, 2007, 17 (11) :2941-2947
[10]  
Brown MS, 2014, EUR RADIOL, V24, P2719, DOI 10.1007/s00330-014-3329-0