A review of setup error in supine breast radiotherapy using cone -beam computed tomography

被引:35
作者
Batumalai, Vikneswary [1 ,2 ,3 ]
Holloway, Lois [1 ,2 ,3 ,4 ,5 ]
Delaney, Geoff P. [1 ,2 ,3 ]
机构
[1] Univ New South Wales, South Western Clin Sch, Sydney, NSW, Australia
[2] Liverpool & Macarthur Canc Therapy Ctr, Campbelltown, NSW, Australia
[3] Ingham Inst Appl Med Res, Sydney, NSW, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[5] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW, Australia
关键词
Breast cancer; Cone-beam computed tomography (CBCT); Radiotherapy; Review; Setup errors; IMAGE-GUIDED RADIOTHERAPY; INTER-FRACTION MOTION; SURGICAL CLIPS; DOSIMETRIC CONSEQUENCES; LUMPECTOMY CAVITY; RADIATION-THERAPY; CLINICAL-PRACTICE; INTRA-FRACTION; WHOLE-BREAST; IRRADIATION;
D O I
10.1016/j.meddos.2016.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT. (C) 2016 American Association of Medical Dosimetrists.
引用
收藏
页码:225 / 229
页数:5
相关论文
共 44 条
  • [1] Image-guided radiotherapy is being overvalued as a clinical tool in radiation oncology
    Amols, Howard I.
    Jaffray, David A.
    Orton, Colin G.
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3583 - 3586
  • [2] [Anonymous], 2003, CANC MAN GUID BREAST
  • [3] Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?
    Batumalai, Vikneswary
    Quinn, Alexandra
    Jameson, Michael
    Delaney, Geoff
    Holloway, Lois
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (01) : 32 - 39
  • [4] Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; First clinical results and comparison with electronic portal-imaging device
    Borst, Gerben R.
    Sonke, Jan-Jakob
    Betgen, Anja
    Remeijer, Peter
    Van Herk, Marcel
    Lebesque, Joos V.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02): : 555 - 561
  • [5] Setup variations in radiotherapy of esophageal cancer: Evaluation by daily megavoltage computed tomographic localization
    Chen, Yi-Jen
    Han, Chunhui
    Liu, An
    Schultheiss, Timothy E.
    Kernstine, Kemp H.
    Shibata, Stephen
    Vora, Nayana L.
    Pezner, Richard D.
    Wong, Jeffrey Y. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (05): : 1537 - 1545
  • [6] Estimation of an optimal radiotherapy utilization rate for breast carcinoma - A review of the evidence
    Delaney, G
    Barton, M
    Jacob, S
    [J]. CANCER, 2003, 98 (09) : 1977 - 1986
  • [7] Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer
    Donovan, E. M.
    James, H.
    Bonora, M.
    Yarnold, J. R.
    Evans, P. M.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 5814 - 5824
  • [8] Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: Results of a prospective study using cone-beam computed tomography
    Fatunase, Toyosi
    Wang, Zhiheng
    Yoo, Sua
    Hubbs, Jessica L.
    Prosnitz, Robert G.
    Yin, Fang-Fang
    Marks, Lawrence B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1025 - 1034
  • [9] Intra- and interfractional reproducibility of tangential breast fields: A prospective on-line portal imaging study
    Fein, DA
    McGee, KP
    Schultheiss, TE
    Fowble, BL
    Hanks, GE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03): : 733 - 740
  • [10] Dosimetric consequences of uncorrected setup errors in helical Tomotherapy treatments of breast-cancer patients
    Goddu, S. Murty
    Yaddanapudi, Sridhar
    Pechenaya, Olga L.
    Chaudhari, Summer R.
    Klein, Eric E.
    Khullar, Divya
    El Naqa, Issam
    Mutic, Sasa
    Wahab, Sasha
    Santanam, Lakshmi
    Zoberi, Imran
    Low, Daniel A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 64 - 70