Evaluation of an AI-based, automatic coronary artery calcium scoring software

被引:50
作者
Sandstedt, Marten [1 ,2 ,3 ]
Henriksson, Lilian [1 ,2 ,3 ]
Janzon, Magnus [4 ,5 ]
Nyberg, Gusten [1 ,2 ,3 ]
Engvall, Jan [1 ,5 ,6 ]
De Geer, Jakob [1 ,2 ,3 ]
Alfredsson, Joakim [4 ,5 ]
Persson, Anders [1 ,2 ,3 ]
机构
[1] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
[2] Linkoping Univ, Univ Hosp Linkoping, Dept Radiol, SE-58185 Linkoping, Sweden
[3] Linkoping Univ, Univ Hosp Linkoping, Dept Med & Hlth Sci, SE-58185 Linkoping, Sweden
[4] Linkoping Univ, Dept Cardiol, Linkoping, Sweden
[5] Linkoping Univ, Dept Med & Hlth Sci, Linkoping, Sweden
[6] Linkoping Univ, Dept Clin Physiol, Linkoping, Sweden
关键词
Artificial intelligence; Software; Coronary artery disease; Multidetector computed tomography; ASSOCIATION TASK-FORCE; COMPUTED-TOMOGRAPHY; CARDIOVASCULAR RISK; AMERICAN-COLLEGE; CARDIAC CT; GUIDELINES; CARDIOLOGY; SCANS;
D O I
10.1007/s00330-019-06489-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate an artificial intelligence (AI)-based, automatic coronary artery calcium (CAC) scoring software, using a semi-automatic software as a reference. Methods This observational study included 315 consecutive, non-contrast-enhanced calcium scoring computed tomography (CSCT) scans. A semi-automatic and an automatic software obtained the Agatston score (AS), the volume score (VS), the mass score (MS), and the number of calcified coronary lesions. Semi-automatic and automatic analysis time were registered, including a manual double-check of the automatic results. Statistical analyses were Spearman's rank correlation coefficient (rho), intra-class correlation (ICC), Bland Altman plots, weighted kappa analysis (kappa), and Wilcoxon signed-rank test. Results The correlation and agreement for the AS, VS, and MS were rho = 0.935, 0.932, 0.934 (p < 0.001), and ICC = 0.996, 0.996, 0.991, respectively (p < 0.001). The correlation and agreement for the number of calcified lesions were rho = 0.903 and ICC = 0.977 (p < 0.001), respectively. The Bland Altman mean difference and 1.96 SD upper and lower limits of agreements for the AS, VS, and MS were - 8.2 (- 115.1 to 98.2), - 7.4 (- 93.9 to 79.1), and - 3.8 (- 33.6 to 25.9), respectively. Agreement in risk category assignment was 89.5% and kappa = 0.919 (p < 0.001). The median time for the semi-automatic and automatic method was 59 s (IQR 35-100) and 36 s (IQR 29-49), respectively (p < 0.001). Conclusions There was an excellent correlation and agreement between the automatic software and the semi-automatic software for three CAC scores and the number of calcified lesions. Risk category classification was accurate but showing an overestimation bias tendency. Also, the automatic method was less time-demanding.
引用
收藏
页码:1671 / 1678
页数:8
相关论文
共 25 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Scoring of coronary artery calcium scans: History, assumptions, current limitations, and future directions [J].
Alluri, Krishna ;
Joshi, Parag H. ;
Henry, Travis S. ;
Blumenthal, Roger S. ;
Nasir, Khurram ;
Blaha, Michael J. .
ATHEROSCLEROSIS, 2015, 239 (01) :109-117
[3]   High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction [J].
Apfaltrer, Georg ;
Albrecht, Moritz H. ;
Schoepf, U. Joseph ;
Duguay, Taylor M. ;
De Cecco, Carlo N. ;
Nance, John W. ;
De Santis, Domenico ;
Apfaltrer, Paul ;
Eid, Marwen H. ;
Eason, Chelsea D. ;
Thompson, Zachary M. ;
Bauer, Maximilian J. ;
Varga-Szemes, Akos ;
Jacobs, Brian E. ;
Sorantin, Erich ;
Tesche, Christian .
EUROPEAN RADIOLOGY, 2018, 28 (07) :3097-3104
[4]   End-to-end lung cancer screening with three-dimensional deep learning on low-dose chest computed tomography [J].
Ardila, Diego ;
Kiraly, Atilla P. ;
Bharadwaj, Sujeeth ;
Choi, Bokyung ;
Reicher, Joshua J. ;
Peng, Lily ;
Tse, Daniel ;
Etemadi, Mozziyar ;
Ye, Wenxing ;
Corrado, Greg ;
Naidich, David P. ;
Shetty, Shravya .
NATURE MEDICINE, 2019, 25 (06) :954-+
[5]   Polypill Therapy, Subclinical Atherosclerosis, and Cardiovascular Events-Implications for the Use of Preventive Pharmacotherapy [J].
Bittencourt, Marcio Sommer ;
Blaha, Michael J. ;
Blankstein, Ron ;
Budoff, Matthew ;
Vargas, Jose D. ;
Blumenthal, Roger S. ;
Agatston, Arthur S. ;
Nasir, Khurram .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (05) :434-443
[6]   Toward the automatic detection of coronary artery calcification in non-contrast computed tomography data [J].
Brunner, Gerd ;
Chittajallu, Deepak R. ;
Kurkure, Uday ;
Kakadiaris, Ioannis A. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (07) :829-838
[7]   Coronary calcium as a predictor of coronary events in four racial or ethnic groups [J].
Detrano, Robert ;
Guerci, Alan D. ;
Carr, J. Jeffrey ;
Bild, Diane E. ;
Burke, Gregory ;
Folsom, Aaron R. ;
Liu, Kiang ;
Shea, Steven ;
Szklo, Moyses ;
Bluemke, David A. ;
O'Leary, Daniel H. ;
Tracy, Russell ;
Watson, Karol ;
Wong, Nathan D. ;
Kronmal, Richard A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (13) :1336-1345
[8]   Growing a Random Forest with Fuzzy Spatial Features for Fully Automatic Artery-Specific Coronary Calcium Scoring [J].
Durlak, Felix ;
Wels, Michael ;
Schwemmer, Chris ;
Suehling, Michael ;
Steidl, Stefan ;
Maier, Andreas .
MACHINE LEARNING IN MEDICAL IMAGING (MLMI 2017), 2017, 10541 :27-35
[9]   Inter-scan variability of coronary artery calcium scoring assessed on 64-multidetector computed tomography vs. dual-source computed tomography: a head-to-head comparison [J].
Ghadri, Jelena R. ;
Goetti, Robert ;
Fiechter, Michael ;
Pazhenkottil, Aju P. ;
Kueest, Silke M. ;
Nkoulou, Rene N. ;
Windler, Christina ;
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Gaemperli, Oliver ;
Templin, Christian ;
Kaufmann, Philipp A. .
EUROPEAN HEART JOURNAL, 2011, 32 (15) :1865-1874
[10]   2013 ACC/AHA Guideline on the Assessment of Cardiovascular Risk A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines [J].
Goff, David C., Jr. ;
Lloyd-Jones, Donald M. ;
Bennett, Glen ;
Coady, Sean ;
D'Agostino, Ralph B., Sr. ;
Gibbons, Raymond ;
Greenland, Philip ;
Lackland, Daniel T. ;
Levy, Daniel ;
O'Donnell, Christopher J. ;
Robinson, Jennifer G. ;
Schwartz, J. Sanford ;
Shero, Susan T. ;
Smith, Sidney C., Jr. ;
Sorlie, Paul ;
Stone, Neil J. ;
Wilson, Peter W. F. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (25) :2935-2959