Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

被引:33
|
作者
Cheung, Joo Yeon [1 ]
Kim, Yookyung [1 ]
Shim, Sung Shine [1 ]
Lim, Soo Mee [1 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Sch Med, Seoul 158710, South Korea
关键词
Biopsy; Cone beam CT; Fluoroscopy; Lung; SOLITARY PULMONARY NODULES; ASPIRATION BIOPSY; DIAGNOSTIC-ACCURACY; LUNG NODULES; COMPUTED-TOMOGRAPHY; GUIDANCE; LESIONS; PNEUMOTHORAX; SAFETY; MASSES;
D O I
10.3348/kjr.2011.12.1.89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). Materials and Methods: We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. Results: The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep (>= 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%; group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 +/- 4.0 minutes, 157.1 +/- 76.5 mGy) than in group B (9.0 +/- 3.5 minutes, 21.9 +/- 15.2 mGy) (p < 0.05). Conclusion: Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions (>= 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [41] Percutaneous CT-guided biopsy: Improved confirmation of sampling site and needle positioning using a multistep technique at CT fluoroscopy
    Goldberg, SN
    Keogan, MT
    Raptopoulos, V
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 264 - 266
  • [42] CT-guided transthoracic needle biopsy of pulmonary lesions: comparison between the cutting needle and aspiration needle
    Huang, Zhen-Guo
    Sun, Hong-Liang
    Wang, Cun-Li
    Gao, Bao-Xiang
    Chen, He
    Yang, Min-Xing
    Chen, Xiao-Liang
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118)
  • [43] CT fluoroscopy-guided biopsy of pulmonary lesions contacting the interlobar fissure: An analysis of 72 biopsies
    Iguchi, Toshihiro
    Matsui, Yusuke
    Tomita, Koji
    Uka, Mayu
    Umakoshi, Noriyuki
    Munetomo, Kazuaki
    Hiraki, Takao
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (06) : 302 - 309
  • [44] CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique
    Wu, Reng-Hong
    Tzeng, Wen-Sheng
    Lee, Wei-Jing
    Chang, Shih-Chin
    Chen, Chia-Huei
    Fung, Jui-Lung
    Wang, Yen-Jen
    Mak, Chee-Wai
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (05) : E712 - E716
  • [45] Initial Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy of Lung Lesions Performed by a Pulmonologist
    Ahn, June Hong
    Jang, Jong Geol
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
  • [46] Diagnostic Accuracy of CT Fluoroscopy-Guided Needle Aspiration Biopsy of Ground-Glass Opacity Pulmonary Lesions
    Hur, Jin
    Lee, Hye-Jeong
    Nam, Ji Eun
    Kim, Young Jin
    Kim, Tae Hoon
    Choe, Kyu Ok
    Choi, Byoung Wook
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 629 - 634
  • [47] CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure
    Iguchi, Toshihiro
    Hiraki, Takao
    Matsui, Yusuke
    Fujiwara, Hiroyasu
    Sakurai, Jun
    Masaoka, Yoshihisa
    Gobara, Hideo
    Kanazawa, Susumu
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 283 - 290
  • [48] Target visibility enhancement for C-arm cone beam CT-fluoroscopy-guided hepatic needle placement: implementation and accuracy evaluation
    Wang, Mengjiao
    Ding, Hui
    Wang, Xiaodong
    Wang, Guangzhi
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (03) : 263 - 273
  • [49] Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance
    Sheth, Niral M.
    Zbijewski, Wojciech
    Jacobson, Matthew W.
    Abiola, Godwin
    Kleinszig, Gerhard
    Vogt, Sebastian
    Soellradl, Stefan
    Bialkowski, Jens
    Anderson, William S.
    Weiss, Clifford R.
    Osgood, Greg M.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2018, 45 (12) : 5420 - 5436
  • [50] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Floridi, Chiara
    Muollo, Alessandra
    Fontana, Federico
    Rotolo, Nicola
    Ierardi, Anna Maria
    Duka, Ejona
    Pellegrino, Carlo
    Carrafiello, Gianpaolo
    RADIOLOGIA MEDICA, 2014, 119 (11): : 820 - 827