Reference values of impulse oscillometry (IOS) for healthy Chinese children aged 4-17 years

被引:5
作者
Wu, Jinhong [1 ]
Zhang, Hao [2 ]
Shi, Yongsheng [3 ]
Wang, Jinrong [4 ]
Han, Yuling [5 ]
Zhang, Qiaoling [6 ]
Wang, Ning [7 ]
Liu, Sha [8 ]
Zhang, Yuehua [9 ]
Zi, Huifen [10 ]
Wang, Fei [11 ]
Liu, Aihong [12 ]
Song, Yuxin [13 ]
Jia, ChunMei [14 ]
Feng, Yong [15 ]
Liu, Quanhua [16 ]
Wan, Liya [17 ]
Ji, Minghong [18 ]
Long, Zhen [19 ]
Huang, Jianfeng [20 ]
Liu, Li [21 ]
Sun, Yun [22 ]
Tang, Suping [23 ]
Dong, Xiaoyan [24 ]
Zhou, Xiaojian [25 ]
Jiang, Wenhui [26 ]
Shen, Li [27 ]
Jiang, Haohua [27 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Shanghai Childrens Med Ctr, Dept Resp Med, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai Childrens Med Ctr, Dept Internal Med, Shanghai 200127, Peoples R China
[3] Matern & Child Care Hosp Gansu Prov, Dept Pediat Resp, Lanzhou 730050, Gansu, Peoples R China
[4] Shandong First Med Univ, Affiliated Prov Hosp, Dept Pediat Resp, Jinan 250021, Peoples R China
[5] Shandong Univ, Qilu Childrens Hosp, Dept Resp, Jinan 250022, Peoples R China
[6] Maternal & Child Hlth Hosp Inner Mongolia Autonom, Dept Pediat Resp, Hohhot 010020, Peoples R China
[7] Xian Childrens Hosp, Asthma Ctr, Xian 710003, Peoples R China
[8] Chongqing Med Univ, Childrens Hosp, Dept Resp Med, Chongqing 400014, Peoples R China
[9] Cent South Univ, Affiliated Haikou Hosp, Xiangya Sch Med, Pediat Infect Dis Ward, Haikou 570208, Hainan, Peoples R China
[10] Baotou Cent Hosp, Dept Pediat, Baotou 014040, Peoples R China
[11] Guiyang Childrens Hosp, Guiyang Maternal & Child Hlth Hosp, Dept Pediat Resp, Guiyang 550003, Peoples R China
[12] Childrens Hosp Shanxi, Dept Resp Med, Taiyuan 030013, Peoples R China
[13] Harbin Childrens Hosp, Dept Allergy, Harbin 150010, Peoples R China
[14] Baotou Childrens Hosp, Hosp Baotou 4, Dept Pediat Resp, Baotou 014030, Peoples R China
[15] China Med Univ, Shengjing Hosp, Dept Pediat, Shenyang 110004, Peoples R China
[16] Shanghai Jiao Tong Univ, Sch Med, Xinhua Hosp, Dept Pulmonol, Shanghai 200092, Peoples R China
[17] Tianjin Childrens Hosp, Resp Dept, Tianjin 300074, Peoples R China
[18] USTC, Anhui Prov Hosp, Affiliated Hosp 1, Dept Pediat, Hefei 230001, Peoples R China
[19] Huazhong Univ Sci & Technol, Maternal & Child Hlth Hosp Hubei Prov, Tongji Med Coll, Dept Pediat Resp Med, Wuhan 430070, Peoples R China
[20] Fudan Univ, Childrens Hosp, Dept Pulmonol, Shanghai 201102, Peoples R China
[21] First Hosp Jilin Univ, Dept Pediat Resp, Changchun 130021, Peoples R China
[22] Yinchuan Women & Children Healthcare Hosp, Gen Pediat, Yinchuan 750001, Ningxia, Peoples R China
[23] Fujian Med Univ, Fuzhou Childrens Hosp, Dept Asthma & Tracheitis, Fuzhou 350000, Peoples R China
[24] Shanghai Jiao Tong Univ, Shanghai Childrens Hosp, Dept Pulmonol, Shanghai 200040, Peoples R China
[25] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Dept Pediat, Shanghai 200080, Peoples R China
[26] Guangzhou Women & Childrens Med Ctr, Dept Resp, Guangzhou 510623, Peoples R China
[27] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Dept Resp, Shanghai 200025, Peoples R China
关键词
Impulse oscillometry; Pulmonary function test; Normal predicted value; Child; BRONCHODILATOR RESPONSE; PULMONARY-FUNCTION; LUNG-FUNCTION; DYSFUNCTION; PARAMETERS; RESISTANCE; IMPEDANCE; EXERCISE; ASTHMA;
D O I
10.1186/s12931-022-02080-z
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objective To establish the predicted value of pulmonary function determined by impulse oscillometry (IOS) in children (4-17 years old) in China. Methods A total of 6270 healthy children aged 4-17 years in China were included. The Master Screen IOS pulmonary function device (Jaeger Co, Germany) was used to detect the respiratory impedance (Zrs), resonant frequency (Fres), respiratory system resistance (Rrs) and respiratory system reactance (Xrs) at various oscillation frequencies, and the indices above were analysed. Stepwise multivariate regression was used to establish the regression equation of related parameters of IOS in different sexes, ages, height, and weight. Results The differences in the main IOS parameters between different age stages were statistically significant regardless of sex (P < 0.05). The stepwise multivariate regression analysis showed that IOS parameters were related to height, age, and weight, and most IOS parameters were most closely related to height (the absolute value of the regression coefficient was the largest). With increasing age and height, the values of Z(5), R-5, R-20, R-5-R-20, and Fres decreased, while the value of X-5 increased. Through height, age, and weight, we obtained the normal predicted values equation of children's IOS parameters. Compared with the other reference equations, our reference equation is more suitable for Chinese children. Conclusions The study revealed the reference values of IOS parameters in healthy Chinese children. In the evaluation of results for lung function measurements, this predicted value equation is more consistent with the characteristics of Chinese children than other reference equations. Clinical Trial: ChiCTR: 1800019029.
引用
收藏
页数:11
相关论文
共 49 条
  • [31] Fractional exhaled nitric oxide (FeNO), Impulse Oscilometry (IOS) and clinical status in 4 to 7 years old asthmatic children
    Andrada, Gabriela
    Donth, Gimena
    Roque, Marcela
    Vocos, Magdalena
    Primrose, Doris
    Velazco Suarez, Carlos
    Kruger, Anahi
    Manuel Figueroa, Juan
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [32] Standard reference for the six-minute-walk test in healthy children aged 7 to 16 years
    Li, Albert M.
    Yin, Jane
    Au, Jun T.
    So, Hung K.
    Tsang, Tony
    Wong, Eric
    Fok, Tai F.
    Ng, Pak C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2007, 176 (02) : 174 - 180
  • [33] Reference Values of the 6-Minute Walk Test in Healthy Turkish Children and Adolescents Between 11 and 18 Years of Age
    Kanburoglu, Mehmet Kenan
    Ozdemir, Fevzi Murat
    Ozkan, Secil
    Tunaoglu, Fatma Sedef
    RESPIRATORY CARE, 2014, 59 (09) : 1369 - 1375
  • [34] Reference equations for the six-minute walk distance in the healthy Chinese population aged 18-59 years
    Zou, He
    Zhu, Xiuruo
    Zhang, Jia
    Wang, Yi
    Wu, Xiaozhen
    Liu, Fang
    Xie, Xiaofeng
    Chen, Xiaoshu
    PLOS ONE, 2017, 12 (09):
  • [35] The oxygen uptake efficiency slope in 1411 Caucasian healthy men and women aged 20-60 years: reference values
    Buys, Roselien
    Coeckelberghs, Ellen
    Vanhees, Luc
    Cornelissen, Veronique A.
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2015, 22 (03) : 356 - 363
  • [36] Spirometric reference values for Hopi Native American children ages 4-13 years
    Arnall, David A.
    Nelson, Arnold G.
    Hearon, Christopher M.
    Interpreter, Christina
    Kanuho, Verdell
    PEDIATRIC PULMONOLOGY, 2016, 51 (04) : 386 - 393
  • [37] Pulmonary function using impulse oscillometry system and clinical outcomes at age 4 years in children born extremely preterm with or without bronchopulmonary dysplasia
    Delestrain, Celine
    Halitim, Kamel
    Tauzin, Manon
    El Jurdi, Houmam
    Jung, Camille
    Hau, Isabelle
    Durrmeyer, Xavier
    Decobert, Fabrice
    Delacourt, Christophe
    Madhi, Fouad
    Epaud, Ralph
    RESPIRATORY MEDICINE, 2024, 234
  • [38] Energy Costs of 37 Physical Activities in Chinese Children and Adolescents Aged 9-17 Years with Obesity
    Zhu, Lin
    Chen, Zekai
    Liu, Jingxin
    Cao, Youxiang
    Liao, Jing
    Xie, Weijun
    NUTRIENTS, 2024, 16 (22)
  • [39] New Danish reference values for height, weight and body mass index of children aged 0-5 years
    Nielsen, A. M.
    Olsen, E. M.
    Juul, A.
    ACTA PAEDIATRICA, 2010, 99 (02) : 268 - 278
  • [40] Reference Equations for the Six-Minute Walk Distance in the Healthy Chinese Han Population, Aged 18-30 Years
    Zou, He
    Zhang, Jia
    Chen, Xiaoshu
    Wang, Yi
    Lin, Wei
    Lin, Jianfeng
    Chen, Hao
    Pan, Jingye
    BMC PULMONARY MEDICINE, 2017, 17