A novel refrigerant-direct radiant cooling system: Numerical simulation-based evaluation

被引:10
作者
Jiang, Tingting [1 ]
You, Shijun [1 ,2 ]
Wu, Zhangxiang [1 ]
Zhang, Huan [1 ,2 ]
Wang, Yaran [1 ,2 ]
Wei, Shen [3 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ene, Minist Educ China, Tianjin 300350, Peoples R China
[3] Univ Coll London UCL, Bartlett Sch Construct & Project Management, 1-19 Torrington Pl, London WC1E 7HB, England
基金
中国国家自然科学基金;
关键词
Refrigerant-direct radiant cooling system; Mathematical and economic models; Thermal and economic performances; Optimal structure; HEAT-TRANSFER; THERMAL COMFORT; CEILING PANEL; FLOOR; DESIGN; HOT; PERFORMANCE; HUMIDITY; CAPACITY;
D O I
10.1016/j.applthermaleng.2021.117442
中图分类号
O414.1 [热力学];
学科分类号
摘要
Split air-conditioners have deficiency in thermal comfort due to draught sensation and fan noise. The existing radiant cooling systems adopt chilled water as circulating medium, resulting in low energy efficiency because of the requirement of secondary heat exchange. To address these problems, a novel refrigerant-direct radiant cooling (RDRC) system is proposed. Experiments are conducted in a climate chamber to evaluate the thermal performance of this system. Results show that the RDRC terminal surface temperature is distributed homogenously and this system has excellent stability. The mathematical and economic models of this terminal are established and the mathematical model is validated with experimental data. The effects of different structural parameters on thermal and economic performances of the RDRC system are investigated, and then this terminal is optimized by orthogonal design method. The cooling capacity for per exterior area is considered as objective function and the initial cost less than 121.1 $ is taken as constraint condition. Results indicate that the fin height of 40.0 mm, the copper pipe diameter of 6.0 mm, the copper pipe spacing of 40.0 mm and the aspect ratio of 0.88 are recommended.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] An experiment-oriented simulation method for cooling capacity determination of cooling ceiling radiant panel system
    Yuan, Yongli
    Zhang, Xu
    Zhou, Xiang
    Gao, Jun
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (06) : 831 - 844
  • [42] NUMERICAL ANALYSIS AND PARAMETRIC STUDY OF A THERMOELECTRIC-BASED RADIANT CEILING PANEL FOR BUILDING COOLING APPLICATIONS
    Seyednezhad, Mohadeseh
    Najafi, Hamidreza
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 8, 2020,
  • [43] Simulation analysis of battery thermal management system for electric vehicles based on direct cooling cycle optimization
    Wang, Ceyi
    Chen, Zhengxian
    Shen, Yang
    Li, Jun
    APPLIED THERMAL ENGINEERING, 2025, 268
  • [44] A Numerical Study on the Exergy Performance of a Hybrid Radiant Cooling System in an Office Building: Comparative Case Study and Analysis
    Liu, Jiying
    Su, Meng
    Fu, Nuodi
    Kim, Moon Keun
    BUILDINGS, 2023, 13 (02)
  • [45] Simulation-based evaluation of an in-vehicle smart situation awareness enhancement system
    Gregoriades, Andreas
    Sutcliffe, Alistair
    ERGONOMICS, 2018, 61 (07) : 947 - 965
  • [46] Simulation-based Evaluation of Workflow Escalation Strategies
    Chan, Ka-Leong
    Si, Yain-Whar
    Dumas, Marlon
    ICEBE 2009: IEEE INTERNATIONAL CONFERENCE ON E-BUSINESS ENGINEERING, PROCEEDINGS, 2009, : 75 - +
  • [47] Simulation on cooling performance characteristics of a refrigerant-cooled active thermal management system for lithium ion batteries
    Park, Seonggi
    Jang, Dong Soo
    Lee, DongChan
    Hong, Seong Ho
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 : 131 - 141
  • [48] A large-scale stochastic simulation-based thermodynamic optimization for the hybrid closed circuit cooling tower system with parallel computing
    Liu, Hua
    Wu, Zhiyong
    Zhang, Bingjian
    Chen, Qinglin
    Pan, Ming
    Ren, Jingzheng
    He, Chang
    ENERGY, 2023, 283
  • [49] Numerical simulation and experimental investigation of air cooling system using thermoelectric cooling system
    Moazzez, A. Fattahpour
    Najafi, G.
    Ghobadian, B.
    Hoseini, S. S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (04) : 2553 - 2563
  • [50] Optimization and Numerical Simulation of Novel Air-cooling System for the Thermal Management of Lithium-ion Battery Pack
    Lin, Xiongchao
    Shao, Keke
    Wang, Caihong