The use of beam angulation to overcome anisotropy when viewing human tendon with high frequency linear array ultrasound

被引:25
作者
Connolly, DJA
Berman, L
McNally, EG
机构
[1] Nuffield Orthopaed Ctr, Dept Radiol, Oxford OX3 7LD, England
[2] Addenbrookes Hosp, Cambridge CB2 2QQ, England
关键词
D O I
10.1259/bjr.74.878.740183
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Anisotropy is the property of tendons, nerves and muscles to vary in their ultrasound appearance depending on the angle of insonation of the incident ultrasound beam. Loss of reflectivity in tendons may also denote underlying disease. We describe beam angulation, a simple technique available with most modern ultrasound machines, which allows the operator to overcome the potential pitfall of anisotropy in ultrasound assessment of peripheral tendons.
引用
收藏
页码:183 / 185
页数:3
相关论文
共 14 条
  • [1] Future and new developments in musculoskeletal ultrasound
    Adler, RS
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 1999, 37 (04) : 623 - +
  • [2] Backhaus M, 1999, ARTHRITIS RHEUM-US, V42, P1232, DOI 10.1002/1529-0131(199906)42:6<1232::AID-ANR21>3.0.CO
  • [3] 2-3
  • [4] High-frequency ultrasound examination of the wrist and hand
    Bianchi, S
    Martinoli, C
    Abdelwahab, MF
    [J]. SKELETAL RADIOLOGY, 1999, 28 (03) : 121 - 129
  • [5] TENDON ECHOGENICITY - EXVIVO STUDY
    CRASS, JR
    VANDEVEGTE, GL
    HARKAVY, LA
    [J]. RADIOLOGY, 1988, 167 (02) : 499 - 501
  • [6] Ultrasonic determination of the anisotropy of Young's modulus of fixed tendon and fixed myocardium
    Hoffmeister, BK
    Handley, SM
    Wickline, SA
    Miller, JG
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (06) : 3933 - 3940
  • [7] COMPARISON OF THE ANISOTROPY OF APPARENT INTEGRATED ULTRASONIC BACKSCATTER FROM FIXED HUMAN TENDON AND FIXED HUMAN MYOCARDIUM
    HOFFMEISTER, BK
    WONG, AK
    VERDONK, ED
    WICKLINE, SA
    MILLER, JG
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (02) : 1307 - 1313
  • [8] Effects of tissue anisotropy on the spectral characteristics of ultrasonic backscatter measured with a clinical imaging system
    Holland, MR
    Lewis, SH
    Hall, CS
    Finch-Johnston, AE
    Handley, SM
    Wallace, KD
    D'Sa, AP
    Prater, DM
    Perez, JE
    Miller, JG
    [J]. ULTRASONIC IMAGING, 1998, 20 (03) : 178 - 190
  • [9] ANISOTROPY OF THE ULTRASONIC BACKSCATTER OF MYOCARDIAL TISSUE .2. MEASUREMENTS INVIVO
    MADARAS, EI
    PEREZ, J
    SOBEL, BE
    MOTTLEY, JG
    MILLER, JG
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (02) : 762 - 769
  • [10] Tendon and nerve sonography
    Martinoli, C
    Bianchi, S
    Derchi, LE
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 1999, 37 (04) : 691 - +