Size-specific dose estimates for pediatric head CT protocols based on the AAPM report TG-293

被引:3
|
作者
Sapignoli, Sonia [1 ]
Roggio, Antonella [1 ]
Boschini, Alessio [2 ]
Guida, Federica [1 ]
Merlo, Carlo [1 ]
Paiusco, Marta [1 ]
Zorz, Alessandra [1 ]
De Monte, Francesca [1 ,3 ]
机构
[1] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Padua, Italy
[2] Med Phys Dept, Azienda ULSS2 Marca Trevigiana, Treviso, Italy
[3] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Via Gattamelata 64, I-35128 Padua, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 100卷
关键词
SSDE; Head CT; Pediatric; Radiation dose tracking system; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; SUBSEQUENT RISK; PATTERNS; CHILDREN; TRENDS; SCAN;
D O I
10.1016/j.ejmp.2022.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish the Size Specific Dose Estimate (SSDE) typical values for pediatric head CT examinations based on the AAPM report TG-293; to provide a new stratification based on the water-equivalent diameter (Dw ), given that SSDE is related to the head size. Methods: 296 Head CT scans of pediatric patients collected using a dose monitoring software were retrospectively analysed. Typical values were derived stratifying data by age in three methods: the first proposed by the European Guidelines on Diagnostic Reference Levels for Pediatric Imaging (RP185), the second by the National Istisan Report 20/22 and a local one related to the clinical protocols (LStrata). For each scan, a self-developed Matlab routine calculated the water-equivalent diameter (Dw) and related SSDE values with the conversion factors fH16and fB16provided by the AAPM reports TG-293 and TG-204, respectively. Eventually, a Dwstratification was introduced starting from a measure of the lateral dimension of the head. Results: SSDE based on TG-204 overestimatesthe dose up to 12%. Four Dwgroups were identified thanks to the good correlation between the head lateral dimension andDw: Dw < 14 cm, 14 < Dw < 16 cm, 16 < Dw < 17 cm, Dw >= 17 cm. The Dw -stratified dosimetric indices present greater variability than those grouped by age because of the large variability of the size of the infant's head. Conclusions: The variability of the SSDE metric underlines that age-optimized protocols are not when size is considered.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 39 条
  • [21] Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE)
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Oda, Seitaro
    Nakaura, Takeshi
    Funama, Yoshinori
    Yuki, Hideaki
    Hirata, Kenichiro
    Namimoto, Tomohiro
    Sakabe, Daisuke
    Hatemura, Masahiro
    Yamashita, Yasuyuki
    EUROPEAN RADIOLOGY, 2017, 27 (06) : 2267 - 2274
  • [22] Evolved size-specific dose estimates for patient-specific organ doses from chest CT scans based on hybrid patient size vectors
    Shao, Wencheng
    Yang, Ke
    Lou, Lizhi
    Lin, Xin
    Qu, Liangyong
    Zhuo, Weihai
    Liu, Haikuan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2025,
  • [23] Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations
    Moore, Bria M.
    Brady, Samuel L.
    Mirro, Amy E.
    Kaufman, Robert A.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [24] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    Larson, David B.
    PEDIATRIC RADIOLOGY, 2014, 44 : 501 - 505
  • [25] Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations
    Moore, B.
    Brady, S.
    Mirro, A.
    Kaufman, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 424 - +
  • [26] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    David B. Larson
    Pediatric Radiology, 2014, 44 : 501 - 505
  • [27] HeadCTDosi: A python']python-based automated calculation of head water equivalent diameter and size specific dose estimate based on AAPM 220 report
    Sekkat, H.
    Khallouqi, A.
    El Rhazouani, O.
    Halimi, A.
    Madkouri, Y.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 227
  • [28] Influence of 320-detector-row volume scanning and AAPM report 111 CT dosimetry metrics on size-specific dose estimate: a Monte Carlo study
    Haba, Tomonobu
    Koyama, Shuji
    Kinomura, Yutaka
    Ida, Yoshihiro
    Kobayashi, Masanao
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (03) : 697 - 703
  • [29] Estimating a size-specific dose for helical head CT examinations using Monte Carlo simulation methods
    Hardy, Anthony J.
    Bostani, Maryam
    Hernandez, Andrew M.
    Zankl, Maria
    McCollough, Cynthia
    Cagnon, Chris
    Boone, John M.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2019, 46 (02) : 902 - 912
  • [30] Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE)
    Einas H. Bashier
    I. I. Suliman
    La radiologia medica, 2018, 123 : 424 - 431