Size-specific dose estimates for pediatric head CT protocols based on the AAPM report TG-293

被引:3
|
作者
Sapignoli, Sonia [1 ]
Roggio, Antonella [1 ]
Boschini, Alessio [2 ]
Guida, Federica [1 ]
Merlo, Carlo [1 ]
Paiusco, Marta [1 ]
Zorz, Alessandra [1 ]
De Monte, Francesca [1 ,3 ]
机构
[1] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Padua, Italy
[2] Med Phys Dept, Azienda ULSS2 Marca Trevigiana, Treviso, Italy
[3] IRCCS, Veneto Inst Oncol IOV, Med Phys Dept, Via Gattamelata 64, I-35128 Padua, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 100卷
关键词
SSDE; Head CT; Pediatric; Radiation dose tracking system; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; SUBSEQUENT RISK; PATTERNS; CHILDREN; TRENDS; SCAN;
D O I
10.1016/j.ejmp.2022.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish the Size Specific Dose Estimate (SSDE) typical values for pediatric head CT examinations based on the AAPM report TG-293; to provide a new stratification based on the water-equivalent diameter (Dw ), given that SSDE is related to the head size. Methods: 296 Head CT scans of pediatric patients collected using a dose monitoring software were retrospectively analysed. Typical values were derived stratifying data by age in three methods: the first proposed by the European Guidelines on Diagnostic Reference Levels for Pediatric Imaging (RP185), the second by the National Istisan Report 20/22 and a local one related to the clinical protocols (LStrata). For each scan, a self-developed Matlab routine calculated the water-equivalent diameter (Dw) and related SSDE values with the conversion factors fH16and fB16provided by the AAPM reports TG-293 and TG-204, respectively. Eventually, a Dwstratification was introduced starting from a measure of the lateral dimension of the head. Results: SSDE based on TG-204 overestimatesthe dose up to 12%. Four Dwgroups were identified thanks to the good correlation between the head lateral dimension andDw: Dw < 14 cm, 14 < Dw < 16 cm, 16 < Dw < 17 cm, Dw >= 17 cm. The Dw -stratified dosimetric indices present greater variability than those grouped by age because of the large variability of the size of the infant's head. Conclusions: The variability of the SSDE metric underlines that age-optimized protocols are not when size is considered.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 39 条
  • [1] THE SIZE-SPECIFIC DOSE ESTIMATE OF PAEDIATRIC HEAD CT EXAMINATIONS FOR VARIOUS PROTOCOLS
    Fahmi, Arif
    Anam, Choirul
    Ali, Mohd Hanafi
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) : 522 - 528
  • [2] Simplifying Size-Specific Radiation Dose Estimates in Pediatric CT
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Vettiyil, Beth
    Lim, Ruth
    Gee, Michael
    Westra, Sjirk
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 167 - 176
  • [3] LOCAL DRLS FOR PAEDIATRIC CT EXAMINATIONS BASED ON SIZE-SPECIFIC DOSE ESTIMATES IN KERMANSHAH, IRAN
    Mohammadbeigi, Ahmad
    Khoshgard, Karim
    Haghparast, Abbas
    Eivazi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2019, 186 (04) : 496 - 506
  • [4] Size-specific dose estimates in pediatric brain CT in relation to age and weight
    Fujii, Kaoru
    Inoue, Yusuke
    Itoh, Hiroyasu
    Sasa, Ryosuke
    Hata, Hirofumi
    Mitsui, Kohei
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (10) : 1075 - 1081
  • [5] Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination
    Tsujiguchi, Takakiyo
    Obara, Hideki
    Ono, Shuichi
    Saito, Yoko
    Kashiwakura, Ikuo
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (04) : 430 - 435
  • [6] A new approach to dose reference levels in pediatric CT: Age and size-specific dose estimation
    Rawashdeh, Mohammad
    Saade, Charbel
    Mousa, Dana S. Al
    Abdelrahman, Mostafa
    Kumar, Praveen
    McEntee, Mark
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [7] Size-specific Dose Estimates for Adult Patients at CT of the Torso
    Christner, Jodie A.
    Braun, Natalie N.
    Jacobsen, Megan C.
    Carter, Rickey E.
    Kofler, James M.
    McCollough, Cynthia H.
    RADIOLOGY, 2012, 265 (03) : 841 - 847
  • [8] Size-specific dose estimations for pediatric chest, abdomen/pelvis and head CT scans with the use of GATE
    Kostou, Theodora
    Papadimitroulas, Panagiotis
    Papaconstadopoulos, Pavlos
    Devic, Slobodan
    Seuntjens, Jan
    Kagadis, George C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 181 - 190
  • [9] Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Chris
    Zankl, Maria
    Sepahdari, Ali R.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2014, 41 (12)
  • [10] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397