Safety and feasibility of robotic-assisted Ivor-Lewis esophagectomy

被引:16
作者
Meredith, K. [1 ]
Huston, J. [1 ]
Andacoglu, O. [2 ]
Shridhar, R. [3 ]
机构
[1] Florida State Univ, Sarasota Mem Hosp, Dept Gastrointestinal Oncol, Sarasota, FL USA
[2] Univ Cent Florida, Dept Radiat Oncol, Orlando, FL 32816 USA
[3] Univ Wisconsin, Dept Surg, Madison, WI USA
关键词
esohageal cancer; esophagectomy; robotic surgery; MINIMALLY INVASIVE ESOPHAGECTOMY; LAPAROSCOPIC ESOPHAGECTOMY; PERIOPERATIVE OUTCOMES; INITIAL-EXPERIENCE; CANCER; MORBIDITY; MORTALITY; SURGERY;
D O I
10.1093/dote/doy005
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Esophagectomy is associated with substantial morbidity. Robotic surgery allows complex resections to be performed with potential benefits over conventional techniques. We applied this technology to transthoracic esophagectomy to assess safety, feasibility, and reliability of this technology. A retrospective cohort study of all patients undergoing robotic-assisted Ivor-Lewis esophagectomy (RAIL) from 2009 to 2014 was conducted. Clinicopathologic factors and surgical outcomes were recorded and compared. All statistical tests were two-sided and a P-value of <0.05 was considered statistically significant. We identified 147 patients with an average age 66 +/- 10 years. Neoadjuvant therapy was administered to 114 (77.6%) patients, and all patients underwent a R0 resection. The mean operating room (OR) time was 415 +/- 84.6 minutes with a median estimated blood loss (EBL) of 150 (25-600) mL. Mean intensive care unit (ICU) stay was 2.00 +/- 4.5 days, median length of hospitalization (LOH) was 9 (4-38) days, and readmissions within 90 days were low at 8 (5.5%). OR time decreased from 471 minutes to 389 minutes after 20 cases and a further decrease to mean of 346 minutes was observed after 120 cases. Complications occurred in 37 patients (25.2%). There were 4 anastomotic (2.7%) leaks. Thirty and 90-day mortality was 0.68% and 1.4%, respectively. This represents to our knowledge the largest series of robotic esophagectomies. RAIL is a safe surgical technique that provides an alternative to standard minimally invasive and open techniques. In our series, there was no increased risk of LOH, complications, or death and re-admission rates were low despite earlier discharge.
引用
收藏
页数:7
相关论文
共 36 条
  • [1] Robotic surgery for gastrointestinal malignancies
    Anderson, C.
    Hellan, M.
    Kernstine, K.
    Ellenhorn, J.
    Lai, L.
    Trisal, V.
    Pigazzi, A.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (04) : 297 - 300
  • [2] [Anonymous], 2013, NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines): Head and Neck Cancers. Version 2
  • [3] Reducing hospital morbidity and mortality following esophagectomy
    Atkins, BZ
    Shah, AS
    Hutcheson, KA
    Mangum, JH
    Pappas, TN
    Harpole, DH
    D'Amico, TA
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (04) : 1170 - 1176
  • [4] Minimally invasive versus open oesophagectomy for patients with oesophageal cancer: a multicentre, open-label, randomised controlled trial
    Biere, Surya S. A. Y.
    Henegouwen, Mark I. van Berge
    Maas, Kirsten W.
    Bonavina, Luigi
    Rosman, Camiel
    Roig Garcia, Josep
    Gisbertz, Suzanne S.
    Klinkenbijl, Jean H. G.
    Hollmann, Markus W.
    de lange, Elly S. M.
    Bonjer, H. Jaap
    van der Peet, Donald L.
    Cuesta, Miguel A.
    [J]. LANCET, 2012, 379 (9829) : 1887 - 1892
  • [5] Initial experience with minimally invasive Ivor Lewis esophagectomy
    Bizekis, Costas
    Kent, Michael S.
    Luketich, James D.
    Buenaventura, Percival O.
    Landreneau, Rodney J.
    Schuchert, Matthew J.
    Alvelo-Rivera, Miguel
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (02) : 402 - 407
  • [6] Ivor Lewis esophagectomy with manual esogastric anastomosis by thoracoscopy in prone position and laparoscopy
    Cadiere, G. B.
    Dapri, G.
    Himpens, J.
    Fodderie, L.
    Rajan, A.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2010, 24 (06): : 1482 - 1485
  • [7] A safe and reproducible anastomotic technique for minimally invasive Ivor Lewis oesophagectomy: the circular-stapled anastomosis with the trans-oral anvil
    Campos, Guilherme M.
    Jablons, David
    Brown, Lisa M.
    Ramirez, Rene M.
    Rabl, Charlotte
    Theodore, Pierre
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 37 (06) : 1421 - 1426
  • [8] The role of robotic assisted laparoscopy for oesophagogastric oncological resection; an appraisal of the literature
    Clark, J.
    Sodergren, M. H.
    Purkayastha, S.
    Mayer, E. K.
    James, D.
    Athanasiou, T.
    Yang, G. -Z.
    Darzi, A.
    [J]. DISEASES OF THE ESOPHAGUS, 2011, 24 (04) : 240 - 250
  • [9] DVORAK HF, 1986, NEW ENGL J MED, V315, P1650
  • [10] Robotically assisted laparoscopic transhiatal esophagectomy
    Galvani, C. A.
    Gorodner, M. V.
    Moser, F.
    Jacobsen, G.
    Chretien, C.
    Espat, N. J.
    Donahue, P.
    Horgan, S.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (01): : 188 - 195