A novel impedimetric glucose biosensor based on immobilized glucose oxidase on a CuO-Chitosan nanobiocomposite modified FTO electrode

被引:44
|
作者
Asrami, Padideh Naderi [1 ]
Mozaffari, Sayed Ahmad [2 ]
Tehrani, Mohammad Saber [1 ]
Azar, Parviz Aberoomand [1 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Chem, Tehran, Iran
[2] IROST, Dept Chem Technol, Thin Layer & Nanotechnol Lab, POB 33535-111, Tehran, Iran
关键词
CuO-Chitosan nanobiocomposite; Glucose biosensor; Reactive DC magnetron sputtering; SELF-ASSEMBLED MONOLAYER; CARBON NANOTUBE ARRAYS; POTENTIOMETRIC SENSOR; UREA BIOSENSOR; NICKEL-OXIDE; THIN-FILMS; ION; GRAPHENE; ZNO; NANOCOMPOSITE;
D O I
10.1016/j.ijbiomac.2018.05.228
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This research aims at elaborating on the construction of a novel nanostructured copper oxide (Nano-CuO) sputtered thin film on the conductive fluorinated-tin oxide (FTO) layer that was exploited to immobilize glucose oxidase (GOx) enzyme via chitosan for developing impedimetric glucose biosensing. The distinct Nano-CuO thin film was fabricated by reactive DC magnetron sputtering system at the optimized instrumental deposition conditions. The FTO/Nano-CuO/Chitosan/GOx biosensor containing several layers afforded excellent microenvironment for rapid biocatalytic reaction to glucose. Field emission-scanning electron microscopy (FE-SEM), Ultraviolet-Visible spectroscopy (UV-Vis), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) were established the morphology of modified electrodes surface and electrochemical behavior of glucose on the fabricated biosensor. Characterization of the surface morphology and roughness of CuO thin film by FE-SEM exhibits cavities of the nanoporous film as an effective biosensing area for covalent enzyme immobilization. Invented FTO/Nano-CuO/Chitosan/GOx biosensor was employed for glucose determination using the impedimetric technique. The impedimetric outcomes display high sensitivity for glucose (0.261 k Omega per mM) detection within 0.2-15 mM and limit of detection as 27 mu M. The declared biosensor has been applied as a careful, noncomplicated, and exact biosensor for recognition of glucose in the real samples analysis. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:649 / 660
页数:12
相关论文
共 50 条
  • [41] Glucose oxidase immobilized PANI cladding modified fiber optic intrinsic biosensor for detection of glucose
    Pahurkar, V. G.
    Tamgadge, Y. S.
    Gambhire, A. B.
    Muley, G. G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 362 - 368
  • [42] Fabrication and Applications of Amperometric Glucose Biosensor Based on CuO Nanowires/Graphene Modified Electrode
    Tian, Liangliang
    Su, Yongyao
    Liao, Wenli
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (18) : 10071 - 10075
  • [43] AN ENZYME ELECTRODE FOR GLUCOSE CONSISTING OF GLUCOSE-OXIDASE IMMOBILIZED AT A BENZOQUINONE-MODIFIED CARBON ELECTRODE
    HU, J
    TURNER, APF
    ANALYTICAL LETTERS, 1991, 24 (01) : 15 - 24
  • [44] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the platinum electrode modified with NiO doped ZnO nanorods
    Chu, Xiangfeng
    Zhu, Xiaohua
    Dong, Yongping
    Chen, Tongyun
    Ye, Mingfu
    Sun, Wenqi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 676 : 20 - 26
  • [45] Glucose Oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing
    Kang, Xinhuang
    Wang, Jun
    Wu, Hong
    Aksay, Ilhan A.
    Liu, Jun
    Lin, Yuehe
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 901 - 905
  • [46] A Glucose Biosensor based on Horseradish Peroxidase and Glucose Oxidase Co-entrapped in Carbon Nanotubes Modified Electrode
    Yang, Han
    Gong, Coucong
    Miao, Longfei
    Xu, Fugang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 4958 - 4969
  • [47] A Glucose Biosensor Based on Deposition of Glucose Oxidase onto Crystalline Gold Nanoparticle Modified Carbon Nanotube Electrode
    Rakhi, Raghavan Baby
    Sethupathi, Kanikrishnan
    Ramaprabhu, Sundara
    JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (10): : 3190 - 3194
  • [48] Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode
    Tang, H
    Chen, JH
    Yao, SZ
    Nie, LH
    Deng, GH
    Kuang, YF
    ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) : 89 - 97
  • [49] Sweat-based Glucose Biosensor Using a Disc Paper Immobilized with Glucose Oxidase
    Baek, Seung-Yeop
    Park, Soo-Young
    POLYMER-KOREA, 2022, 46 (03) : 342 - 347
  • [50] Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yin, Feng
    Li, Jing
    Zhao, Zi-Xia
    Huang, Jia-Dong
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 838 - 844