A novel impedimetric glucose biosensor based on immobilized glucose oxidase on a CuO-Chitosan nanobiocomposite modified FTO electrode

被引:44
|
作者
Asrami, Padideh Naderi [1 ]
Mozaffari, Sayed Ahmad [2 ]
Tehrani, Mohammad Saber [1 ]
Azar, Parviz Aberoomand [1 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Dept Chem, Tehran, Iran
[2] IROST, Dept Chem Technol, Thin Layer & Nanotechnol Lab, POB 33535-111, Tehran, Iran
关键词
CuO-Chitosan nanobiocomposite; Glucose biosensor; Reactive DC magnetron sputtering; SELF-ASSEMBLED MONOLAYER; CARBON NANOTUBE ARRAYS; POTENTIOMETRIC SENSOR; UREA BIOSENSOR; NICKEL-OXIDE; THIN-FILMS; ION; GRAPHENE; ZNO; NANOCOMPOSITE;
D O I
10.1016/j.ijbiomac.2018.05.228
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This research aims at elaborating on the construction of a novel nanostructured copper oxide (Nano-CuO) sputtered thin film on the conductive fluorinated-tin oxide (FTO) layer that was exploited to immobilize glucose oxidase (GOx) enzyme via chitosan for developing impedimetric glucose biosensing. The distinct Nano-CuO thin film was fabricated by reactive DC magnetron sputtering system at the optimized instrumental deposition conditions. The FTO/Nano-CuO/Chitosan/GOx biosensor containing several layers afforded excellent microenvironment for rapid biocatalytic reaction to glucose. Field emission-scanning electron microscopy (FE-SEM), Ultraviolet-Visible spectroscopy (UV-Vis), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) were established the morphology of modified electrodes surface and electrochemical behavior of glucose on the fabricated biosensor. Characterization of the surface morphology and roughness of CuO thin film by FE-SEM exhibits cavities of the nanoporous film as an effective biosensing area for covalent enzyme immobilization. Invented FTO/Nano-CuO/Chitosan/GOx biosensor was employed for glucose determination using the impedimetric technique. The impedimetric outcomes display high sensitivity for glucose (0.261 k Omega per mM) detection within 0.2-15 mM and limit of detection as 27 mu M. The declared biosensor has been applied as a careful, noncomplicated, and exact biosensor for recognition of glucose in the real samples analysis. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:649 / 660
页数:12
相关论文
共 50 条
  • [31] A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes
    Kang, Xinhuang
    Mai, Zhibin
    Zou, Xiaoyong
    Cai, Peixiang
    Mo, Jinyuan
    ANALYTICAL BIOCHEMISTRY, 2007, 369 (01) : 71 - 79
  • [32] Determination of Glucose using a Biosensor Based on Glucose Oxidase Immobilized on a Molybdenite-Decorated Glassy Carbon Electrode
    Zhao, Rui
    Wang, Yue
    Hasebe, Yasushi
    Zhang, Zhiqiang
    Tao, Dongping
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (02): : 1595 - 1605
  • [33] Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 122 - 128
  • [34] Glucose determination in blood samples using flow injection analysis and an amperometric biosensor based on glucose oxidase immobilized on hexacyanoferrate modified nickel electrode
    Milardovic, S
    Kruhak, I
    Ivekovic, D
    Rumenjak, V
    Tkalcec, M
    Grabaric, BS
    ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) : 91 - 96
  • [35] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the CuGeO3 nanowire modified electrode
    Yong Ping Dong
    Li Huang
    Xiang Feng Chu
    Li Zhai Pei
    Russian Journal of Electrochemistry, 2013, 49 : 571 - 576
  • [36] Electrochemical Biosensor of Glucose Based on the Immobilization of Glucose Oxidase on a Carbon Microsphere Modified Glassy Carbon Electrode
    Dong, Yong Ping
    Huang, Li
    Lei, Zhi Ping
    Chu, Xiang Feng
    Zhang, Qian Feng
    SENSOR LETTERS, 2012, 10 (3-4) : 1024 - 1030
  • [37] An Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the CuGeO3 Nanowire Modified Electrode
    Dong, Yong Ping
    Huang, Li
    Chu, Xiang Feng
    Pei, Li Zhai
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (06) : 571 - 576
  • [38] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zaide Zhou
    Lina Qiao
    Peng Zhang
    Dan Xiao
    Martin M. F. Choi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 673 - 679
  • [39] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zhou, ZD
    Qiao, L
    Zhang, P
    Xiao, D
    Choi, MMF
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 673 - 679
  • [40] Potentiometric glucose sensor based on the glucose oxidase immobilized iron ferrite magnetic particle/chitosan composite modified gold coated glass electrode
    Khun, K.
    Ibupoto, Z. H.
    Lu, J.
    AlSalhi, M. S.
    Atif, M.
    Ansari, Anees A.
    Willander, M.