Measurement of urinary oxypurinol by high performance liquid chromatography-tandem mass spectrometry

被引:12
|
作者
Stocker, Sophie L. [2 ]
Franklin, Michael E. [1 ]
Anderson, Jacqueline M. [3 ,4 ]
Pillans, Peter I. [1 ]
Williams, Kenneth M. [3 ,4 ]
McLachlan, Andrew J. [2 ,5 ]
Day, Richard O. [3 ,4 ]
Taylor, Paul J. [1 ]
机构
[1] Princess Alexandra Hosp, Dept Clin Pharmacol, Brisbane, Qld 4102, Australia
[2] Univ Sydney, Fac Pharm, Sydney, NSW 2006, Australia
[3] St Vincents Hosp, Dept Clin Pharmacol, Sydney, NSW 2010, Australia
[4] Univ New S Wales, Sydney, NSW 2010, Australia
[5] Concord Hosp, Ctr Educ & Res Ageing, Sydney, NSW, Australia
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 25期
基金
澳大利亚国家健康与医学研究理事会;
关键词
Oxypurinol; Urine; HPLC; Mass spectrometry; Gout; HUMAN-PLASMA; URIC-ACID; ALLOPURINOL; GOUT; OXIPURINOL; ADHERENCE; PATTERNS; THERAPY; PURINES; FLUIDS;
D O I
10.1016/j.jchromb.2010.07.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxypurinol is the active metabolite of allopurinol which is used to treat hyperuricaemia associated with gout. Both oxypurinol and allopurinol inhibit xanthine oxidase which forms uric acid from xanthine and hypoxanthine. Plasma oxypurinol concentrations vary substantially between individuals and the source of this variability remains unclear. The aim of this study was to develop an HPLC-tandem mass spectrometry method to measure oxypurinol in urine to facilitate the study of the renal elimination of oxypurinol in patients with gout. Urine samples (50 mu L) were prepared by dilution with a solution of acetonitrile/methanol/water (95/2/3, v/v; 2 mL) that contained the internal standard (8-methylxanthine; 1.5 mg/L), followed by centrifugation. An aliquot (2 mu L) was injected. Chromatography was performed on an Atlantis HILIC Silica column (31 mu m, 100 mm x 2.1 mm, Waters) at 30 C, using a mobile phase comprised of acetonitrile/methanol/50 mM ammonium acetate in 0.2% formic acid (95/2/3, v/v). Using a flow rate of 0.35 mL/min, the analysis time was 6.0 min. Mass spectrometric detection was by selected reactant monitoring (oxypurinol: m/z 150.8 -> 108.0; internal standard: m/z 164.9 -> 121.8) in negative electrospray ionization mode. Calibration curves were prepared in drug-free urine across the range 10-200 mg/L and fitted using quadratic regression with a weighting factor of 1/x (r(2) > 0.997, n = 7). Quality control samples (20, 80, 150 and 300 mg/L) were used to determine intra-day (n = 5) and inter-day (n = 7) accuracy and imprecision. The inter-day accuracy and imprecision was 96.1-104% and < 11.2%, respectively. Urinary oxypurinol samples were stable when subjected to 3 freeze-thaw cycles and when stored at room temperature for up to 6h. Samples collected from 10 patients, not receiving allopurinol therapy, were screened and showed no significant interferences. The method was suitable for the quantification of oxypurinol in the urine of patients (n = 34) participating in a clinical trial to optimize therapy of gout with allopurinol. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:2363 / 2368
页数:6
相关论文
共 50 条
  • [31] Analysis of urinary sphingolipids using liquid chromatography-tandem mass spectrometry in diabetic nephropathy
    Morita, Yoshifumi
    Kurano, Makoto
    Sakai, Eri
    Nishikawa, Takako
    Nishikawa, Masako
    Sawabe, Motoji
    Aoki, Junken
    Yatomi, Yutaka
    JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (02) : 441 - 449
  • [32] Targeted and untargeted urinary metabolomics of alkaptonuria patients using ultra high-performance liquid chromatography-tandem mass spectrometry
    Serafimov, Kristian
    Tischlarik, Johanna Ruth
    Laemmerhofer, Michael
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 256
  • [33] Method for measurement of the quaternary amine compounds paraquat and diquat in human urine using high-performance liquid chromatography-tandem mass spectrometry
    Whitehead, Ralph D., Jr.
    Montesano, M. Angela
    Jayatilaka, Nayana K.
    Buckley, Brian
    Winnik, Bozena
    Needham, Larry L.
    Barr, Dana Boyd
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (27): : 2548 - 2553
  • [34] Therapeutic drug monitoring of topiramate by liquid chromatography-tandem mass spectrometry
    Matar, Kamal M.
    CLINICA CHIMICA ACTA, 2010, 411 (9-10) : 729 - 734
  • [35] Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine
    Urdigere, Anil Kumar Rangachar
    Besagarahally, Bhasakra Laxmaiah
    Basavaiah, Kanakapura
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (05) : 1381 - 1387
  • [36] Determination of muscimol and ibotenic acid in Amanita mushrooms by high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry
    Tsujikawa, Kenji
    Kuwayama, Kenji
    Miyaguchi, Hajime
    Kanamori, Tatsuyuki
    Iwata, Yuko
    Inoue, Hiroyuki
    Yoshida, Takemi
    Kishi, Tohru
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 430 - 435
  • [37] Circulating choline and phosphocholine measurement by a hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Guerra, Giulia
    Segrado, Francesco
    Pasanisi, Patrizia
    Bruno, Eleonora
    Lopez, Salvatore
    Raspagliesi, Francesco
    Bianchi, Michela
    Venturelli, Elisabetta
    HELIYON, 2023, 9 (11)
  • [38] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [39] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [40] Determination of 19 drugs of abuse and metabolites in whole blood by high-performance liquid chromatography-tandem mass spectrometry
    Bjork, Marie Kjaergaard
    Nielsen, Marie K. K.
    Markussen, Lotte O.
    Klinke, Helene B.
    Linnet, Kristian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) : 2393 - 2401