Measurement of urinary oxypurinol by high performance liquid chromatography-tandem mass spectrometry

被引:11
|
作者
Stocker, Sophie L. [2 ]
Franklin, Michael E. [1 ]
Anderson, Jacqueline M. [3 ,4 ]
Pillans, Peter I. [1 ]
Williams, Kenneth M. [3 ,4 ]
McLachlan, Andrew J. [2 ,5 ]
Day, Richard O. [3 ,4 ]
Taylor, Paul J. [1 ]
机构
[1] Princess Alexandra Hosp, Dept Clin Pharmacol, Brisbane, Qld 4102, Australia
[2] Univ Sydney, Fac Pharm, Sydney, NSW 2006, Australia
[3] St Vincents Hosp, Dept Clin Pharmacol, Sydney, NSW 2010, Australia
[4] Univ New S Wales, Sydney, NSW 2010, Australia
[5] Concord Hosp, Ctr Educ & Res Ageing, Sydney, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
Oxypurinol; Urine; HPLC; Mass spectrometry; Gout; HUMAN-PLASMA; URIC-ACID; ALLOPURINOL; GOUT; OXIPURINOL; ADHERENCE; PATTERNS; THERAPY; PURINES; FLUIDS;
D O I
10.1016/j.jchromb.2010.07.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxypurinol is the active metabolite of allopurinol which is used to treat hyperuricaemia associated with gout. Both oxypurinol and allopurinol inhibit xanthine oxidase which forms uric acid from xanthine and hypoxanthine. Plasma oxypurinol concentrations vary substantially between individuals and the source of this variability remains unclear. The aim of this study was to develop an HPLC-tandem mass spectrometry method to measure oxypurinol in urine to facilitate the study of the renal elimination of oxypurinol in patients with gout. Urine samples (50 mu L) were prepared by dilution with a solution of acetonitrile/methanol/water (95/2/3, v/v; 2 mL) that contained the internal standard (8-methylxanthine; 1.5 mg/L), followed by centrifugation. An aliquot (2 mu L) was injected. Chromatography was performed on an Atlantis HILIC Silica column (31 mu m, 100 mm x 2.1 mm, Waters) at 30 C, using a mobile phase comprised of acetonitrile/methanol/50 mM ammonium acetate in 0.2% formic acid (95/2/3, v/v). Using a flow rate of 0.35 mL/min, the analysis time was 6.0 min. Mass spectrometric detection was by selected reactant monitoring (oxypurinol: m/z 150.8 -> 108.0; internal standard: m/z 164.9 -> 121.8) in negative electrospray ionization mode. Calibration curves were prepared in drug-free urine across the range 10-200 mg/L and fitted using quadratic regression with a weighting factor of 1/x (r(2) > 0.997, n = 7). Quality control samples (20, 80, 150 and 300 mg/L) were used to determine intra-day (n = 5) and inter-day (n = 7) accuracy and imprecision. The inter-day accuracy and imprecision was 96.1-104% and < 11.2%, respectively. Urinary oxypurinol samples were stable when subjected to 3 freeze-thaw cycles and when stored at room temperature for up to 6h. Samples collected from 10 patients, not receiving allopurinol therapy, were screened and showed no significant interferences. The method was suitable for the quantification of oxypurinol in the urine of patients (n = 34) participating in a clinical trial to optimize therapy of gout with allopurinol. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:2363 / 2368
页数:6
相关论文
共 50 条
  • [21] Measurement of Sufentanil in Human Milk by Liquid Chromatography-Tandem Mass Spectrometry
    Huang, Yangfa
    Liao, Lianming
    Zeng, Manlin
    Huang, Qijian
    Zeng, Jian
    Zhang, Liangcheng
    JOURNAL OF BIOBASED MATERIALS AND BIOENERGY, 2023, 17 (04) : 492 - 497
  • [22] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [23] Determination of five coumarins in toys by high performance liquid chromatography-tandem mass spectrometry
    Yang Rongjing
    Wei Biwen
    Gao Huan
    Yu Wenjia
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (02) : 160 - 164
  • [24] High-performance liquid chromatography-tandem mass spectrometry of enterostatins in biological samples
    Liu, YM
    Vaughn, K
    Song, Y
    Prasad, C
    ANALYTICA CHIMICA ACTA, 2004, 508 (02) : 159 - 164
  • [25] Determination of cefalonium residue in milk by high performance liquid chromatography-tandem mass spectrometry
    Li Shuaipeng
    Guo Chunna
    Meng Lei
    Huang Xianhui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (05) : 519 - 523
  • [26] Separation and identification of the impurities in monosialotetrahexosylgangliosides by high performance liquid chromatography-tandem mass spectrometry
    Wang Hua
    Xu Yuan
    Liang Feng
    Qi Yanxia
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (01) : 29 - 33
  • [27] Oxidation Monitoring of Cyclolinopeptide in Flaxseed by High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Zhu Li-Li
    Chen Da-Yong
    Tong Wen-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (04) : 512 - 519
  • [28] High-performance liquid chromatography-tandem mass spectrometry for the determination of sulfonamides in eggs
    Tamosiunas, Vytautas
    Padarauskas, Audrius
    CHEMIJA, 2007, 18 (03): : 20 - 24
  • [30] Determination of streptomycin and dihydrostreptomycin in pollens by high performance liquid chromatography-tandem mass spectrometry
    Huang Juan
    Yin Yao
    Xu Jinzhong
    Liu Yan
    Chen Guosong
    Zhang Xiaoyan
    Yang Wenquan
    Sheng Chongyu
    Chen Huilan
    Zhang Rui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (06) : 566 - 572