Measurement of urinary oxypurinol by high performance liquid chromatography-tandem mass spectrometry

被引:12
|
作者
Stocker, Sophie L. [2 ]
Franklin, Michael E. [1 ]
Anderson, Jacqueline M. [3 ,4 ]
Pillans, Peter I. [1 ]
Williams, Kenneth M. [3 ,4 ]
McLachlan, Andrew J. [2 ,5 ]
Day, Richard O. [3 ,4 ]
Taylor, Paul J. [1 ]
机构
[1] Princess Alexandra Hosp, Dept Clin Pharmacol, Brisbane, Qld 4102, Australia
[2] Univ Sydney, Fac Pharm, Sydney, NSW 2006, Australia
[3] St Vincents Hosp, Dept Clin Pharmacol, Sydney, NSW 2010, Australia
[4] Univ New S Wales, Sydney, NSW 2010, Australia
[5] Concord Hosp, Ctr Educ & Res Ageing, Sydney, NSW, Australia
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 25期
基金
澳大利亚国家健康与医学研究理事会;
关键词
Oxypurinol; Urine; HPLC; Mass spectrometry; Gout; HUMAN-PLASMA; URIC-ACID; ALLOPURINOL; GOUT; OXIPURINOL; ADHERENCE; PATTERNS; THERAPY; PURINES; FLUIDS;
D O I
10.1016/j.jchromb.2010.07.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxypurinol is the active metabolite of allopurinol which is used to treat hyperuricaemia associated with gout. Both oxypurinol and allopurinol inhibit xanthine oxidase which forms uric acid from xanthine and hypoxanthine. Plasma oxypurinol concentrations vary substantially between individuals and the source of this variability remains unclear. The aim of this study was to develop an HPLC-tandem mass spectrometry method to measure oxypurinol in urine to facilitate the study of the renal elimination of oxypurinol in patients with gout. Urine samples (50 mu L) were prepared by dilution with a solution of acetonitrile/methanol/water (95/2/3, v/v; 2 mL) that contained the internal standard (8-methylxanthine; 1.5 mg/L), followed by centrifugation. An aliquot (2 mu L) was injected. Chromatography was performed on an Atlantis HILIC Silica column (31 mu m, 100 mm x 2.1 mm, Waters) at 30 C, using a mobile phase comprised of acetonitrile/methanol/50 mM ammonium acetate in 0.2% formic acid (95/2/3, v/v). Using a flow rate of 0.35 mL/min, the analysis time was 6.0 min. Mass spectrometric detection was by selected reactant monitoring (oxypurinol: m/z 150.8 -> 108.0; internal standard: m/z 164.9 -> 121.8) in negative electrospray ionization mode. Calibration curves were prepared in drug-free urine across the range 10-200 mg/L and fitted using quadratic regression with a weighting factor of 1/x (r(2) > 0.997, n = 7). Quality control samples (20, 80, 150 and 300 mg/L) were used to determine intra-day (n = 5) and inter-day (n = 7) accuracy and imprecision. The inter-day accuracy and imprecision was 96.1-104% and < 11.2%, respectively. Urinary oxypurinol samples were stable when subjected to 3 freeze-thaw cycles and when stored at room temperature for up to 6h. Samples collected from 10 patients, not receiving allopurinol therapy, were screened and showed no significant interferences. The method was suitable for the quantification of oxypurinol in the urine of patients (n = 34) participating in a clinical trial to optimize therapy of gout with allopurinol. (C) 2010 Elsevier BM. All rights reserved.
引用
收藏
页码:2363 / 2368
页数:6
相关论文
共 50 条
  • [1] Determination of allopurinol and oxypurinol in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Liu, Xia
    Ni, Xiao-Jia
    Shang, De-Wei
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Luo, Fu-Tian
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 941 : 10 - 16
  • [2] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [3] Development of quantitative assay for simultaneous measurement of purine metabolites and creatinine in biobanked urine by liquid chromatography-tandem mass spectrometry
    Svistounov, Dmitri
    Solbu, Marit D.
    Jenssen, Trond G.
    Mathisen, Ulla Dorte
    Hansen, Terkel
    Elgstoen, Katja Benedikte Presto
    Zykova, Svetlana N.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2022, 82 (01) : 37 - 49
  • [4] Simultaneous analysis of allopurinol and oxypurinol using a validated liquid chromatography-tandem mass spectrometry method in human plasma
    Rathod, Dhiraj M.
    Patel, Keyur R.
    Mistri, Hiren N.
    Jangid, Arvind G.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (01) : 56 - 62
  • [5] Identification of human urinary metabolites of acetochlor in exposed herbicide applicators by high-performance liquid chromatography-tandem mass spectrometry
    Barr, Dana B.
    Hines, Cynthia J.
    Olsson, Anders O.
    Deddens, James A.
    Bravo, Roberto
    Striley, Cynthia A. F.
    Norrgran, Jessica
    Needham, Larry L.
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2007, 17 (06) : 559 - 566
  • [6] Identification of human urinary metabolites of acetochlor in exposed herbicide applicators by high-performance liquid chromatography-tandem mass spectrometry
    Dana B Barr
    Cynthia J Hines
    Anders O Olsson
    James A Deddens
    Roberto Bravo
    Cynthia A F Striley
    Jessica Norrgran
    Larry L Needham
    Journal of Exposure Science & Environmental Epidemiology, 2007, 17 : 559 - 566
  • [7] Special Considerations for Liquid Chromatography-Tandem Mass Spectrometry Method Development
    Rappold, Brian A.
    CLINICS IN LABORATORY MEDICINE, 2018, 38 (03) : 539 - +
  • [8] Development of a high-performance liquid chromatography - Tandem mass spectrometry urinary pterinomics workflow
    Burton, Casey
    Shi, Honglan
    Ma, Yinfa
    ANALYTICA CHIMICA ACTA, 2016, 927 : 72 - 81
  • [9] Liquid chromatography-tandem mass spectrometry in clinical laboratory protein measurement
    Ma, Yichen
    Wang, Danchen
    Li, Honglei
    Ma, Xiaoli
    Zou, Yutong
    Mu, Danni
    Yu, Songlin
    Cheng, Xinqi
    Qiu, Ling
    CLINICA CHIMICA ACTA, 2024, 562
  • [10] High-performance liquid chromatography-tandem mass spectrometry of enterostatins in biological samples
    Liu, YM
    Vaughn, K
    Song, Y
    Prasad, C
    ANALYTICA CHIMICA ACTA, 2004, 508 (02) : 159 - 164