The relative performance of NDIR-based sensors in the near real-time analysis of CO2 in air

被引:49
作者
Pandey, Sudhir Kumar [1 ]
Kim, Ki-Hyun [1 ]
机构
[1] Sejong Univ, Dept Earth & Environm Sci, Seoul 143747, South Korea
关键词
NDIR sensor; CO2; monitoring; side-by-side analysis; performance evaluation;
D O I
10.3390/s7091683
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the reliability of NDIR-based sensors was explored by evaluating the comparability between measurement systems in the near real-time analysis of CO2. For this purpose, replicate analyses were performed using sensors of two different model types (H-550 and B-530, ELT Company, Korea). Three replicate data of each sensor type collected continuously by side-by-side analysis in three second intervals (a duration of 304 hour) were evaluated for the relative performance of NDIR sensors. The reproducibility of sensors, when assessed by relative standard error (RSE%) values of all sensor units, showed moderate changes with time with the overall mean of 2.33%. When CO2 measurements from all NDIR sensor units were evaluated by correlation analysis, the results showed strong comparability, regardless of the model type. The overall results of this study suggest that NDIR sensors are reliable enough to produce highly comparable data at least in a relative sense.
引用
收藏
页码:1683 / 1696
页数:14
相关论文
共 36 条
[1]   Measuring the CO2 flux at the air/water interface in lakes using flow injection analysis [J].
Almeida, FV ;
Guimarares, JR ;
Jardim, WF .
JOURNAL OF ENVIRONMENTAL MONITORING, 2001, 3 (03) :317-321
[2]  
BAADENHUIJSEN H, 1979, CLIN CHEM, V25, P443
[3]  
BRUCKENSTEIN S, 1986, ANAL CHEM, V58, P1766, DOI 10.1021/ac00121a037
[4]   Determination of the respiration rate of tomato fruit using flow analysis [J].
Calegario, FF ;
Cosso, RG ;
Almeida, FV ;
Vercesi, AE ;
Jardim, WF .
POSTHARVEST BIOLOGY AND TECHNOLOGY, 2001, 22 (03) :249-256
[5]   Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information [J].
Daisey, JM ;
Angell, WJ ;
Apte, MG .
INDOOR AIR, 2003, 13 (01) :53-64
[6]   Precision trace cas analysis by FT-IR spectroscopy.: 1.: Simultaneous analysis of CO2, CH4, N2O, and CO in air [J].
Esler, MB ;
Griffith, DWT ;
Wilson, SR ;
Steele, LP .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :206-215
[7]  
Ferng SF, 2002, J ENVIRON HEALTH, V65, P14
[8]   ANALYSIS OF TRACE POLLUTANTS IN AIR BY MEANS OF CRYOGENIC GAS-CHROMATOGRAPHY [J].
GIANNOVARIO, JA ;
GROB, RL ;
RULON, PW .
JOURNAL OF CHROMATOGRAPHY, 1976, 121 (02) :285-294
[9]   Sick building syndrome - A case study in a multistory centrally air-conditioned building in the Delhi City [J].
Gupta, Sanjeev ;
Khare, Mukesh ;
Goyal, Radha .
BUILDING AND ENVIRONMENT, 2007, 42 (08) :2797-2809
[10]  
HANNAN J, 1997, ITEST B, V28, P9