Frequency of Need for Antitachycardia or Antibradycardia Pacing or Cardiac Resynchronization Therapy in Patients With a Single-Chamber Implantable Cardioverter-Defibrillator

被引:6
|
作者
Melles, Mireille C. [1 ]
Yap, Sing-Chien [1 ]
Bhagwandien, Rohit E. [1 ]
Sakhi, Rafi [1 ]
Szili-Torok, Tamas [1 ]
Theuns, Dominic A. M. J. [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Rotterdam, Netherlands
关键词
TRIAL; EFFICACY; REGISTRY; SAFETY; RISK;
D O I
10.1016/j.amjcard.2018.08.059
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is unable to deliver antitachycardia pacing (ATP), bradycardia pacing, and cardiac resynchronization therapy (CRT). However, little is known about the proportion of patients that develop the need for 1 of these features. We evaluated the potential suitability for a S-ICD at the time of first replacement in a cohort of patients with a transvenous single-chamber device who did not need bradycardia pacing at the time of implantation. The study cohort consisted of patients who received a transvenous single-chamber ICD between 1998 and September 2017. The primary end point was a combined end point of the need for atrial or ventricular pacing, development of a CRT indication, or termination of ventricular arrhythmias by ATP delivery. During a mean follow-up of 5.6 +/- 1.9 years, 78 of 254 patients (31%) reached the primary end point. The 7 years' cumulative S-ICD suitability rate was 65.6% (95% confidence interval [CI] 58.5% to 71.7%). Event rates were 9.5% (95% CI 6.5% to 13.9%) at 1-year follow-up, and 28.0% (95% CI 22.8% to 34.2%) at 5 years' follow-up. For individual end points, incidence rates were 1.8 (95% CI 1.2 to 2.6) per 100-patientyears for CRT, 0.3 (95% CI 0.1 to 0.8) per 100-patient-years for pacing-dependency, and 4.9 (95% CI 3.8 to 6.3) per 100-patient-years for appropriate ATP therapy. No baseline variables for predicting S-ICD unsuitability were found. In conclusion, at the time of the first replacement, 69% of the patients with a single-chamber device would have been clinically eligible for the S-ICD. Incidence rates of developing a bradycardia pacing and CRT indication are low. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:2068 / 2074
页数:7
相关论文
共 50 条
  • [41] Avoiding inappropriate therapy of single-lead implantable cardioverter-defibrillator by using atrial-sensing electrodes
    Kurt, Muhammed
    Jathanna, Nikesh
    Babady, Mehran
    Schmidt, Jan
    Mueller, Patrick
    Gerguri, Shqipe
    Clasen, Lukas
    Bejinariu, Alexandru
    Kelm, Malte
    Fuernkranz, Alexander
    Makimoto, Hisaki
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (12) : 1682 - 1689
  • [42] The role of atrial sensing for new-onset atrial arrhythmias diagnosis and management in single-chamber implantable cardioverter-defibrillator recipients: Results from the THINGS registry
    Biffi, Mauro
    Iori, Matteo
    De Maria, Elia
    Bolognesi, Maria Giulia
    Placci, Angelo
    Calvi, Valeria
    Allocca, Giuseppe
    Ammendola, Ernesto
    Carinci, Valeria
    Boggian, Giulio
    Saporito, Davide
    Grassini, Diego
    Giacopelli, Daniele
    Statuto, Giovanni
    Ziacchi, Matteo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (04) : 846 - 853
  • [43] Primary prevention implantable cardioverter defibrillator in cardiac resynchronization therapy recipients with advanced chronic kidney disease
    Goldenberg, Ido
    Kutyifa, Valentina
    Zareba, Wojciech
    Huang, David Tsu-Chau
    Rosero, Spencer Z.
    Younis, Arwa
    Schuger, Claudio
    Gao, Anna
    Mcnitt, Scott
    Polonsky, Bronislava
    Steinberg, Jonathan S.
    Goldenberg, Ilan
    Aktas, Mehmet K.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [44] Use of implantable cardioverter defibrillator and cardiac resynchronization therapy: an Italian survey study on 220 cardiology departments
    Inama, Giuseppe
    Pedrinazzi, Claudio
    Landolina, Maurizio
    Oliva, Fabrizio
    Senni, Michele
    Proclemer, Alessandro
    Berisso, Massimo Zoni
    Pirelli, Salvatore
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2012, 13 (11) : 675 - 683
  • [45] Clinical characteristics and outcomes of elderly patients treated with an implantable cardioverter-defibrillator or cardiac resynchronization therapy in a real-world setting: Data from the Israeli ICD Registry
    Suleiman, Mahmoud
    Goldenberg, Ilan
    Haim, Moti
    Schliamser, Jorge E.
    Boulos, Monther
    Ilan, Michael
    Swissa, Moshe
    Gavrielov-Yusim, Natalie
    Fuchs, Therese
    Amit, Guy
    Glikson, Michael
    HEART RHYTHM, 2014, 11 (03) : 435 - 441
  • [46] Mortality benefits from implantable cardioverter-defibrillator therapy are not restricted to patients with remote myocardial infarction
    Tracy, Cynthia M.
    HEART RHYTHM, 2011, 8 (03) : 401 - 402
  • [47] Implementation of guidelines for implantable cardioverter-defibrillator therapy in clinical practice: Which patients do benefit?
    Wijers, S. C.
    van der Kolk, B. Y. M.
    Tuinenburg, A. E.
    Doevendans, P. A. F.
    Vos, M. A.
    Meine, M.
    NETHERLANDS HEART JOURNAL, 2013, 21 (06) : 274 - 283
  • [48] Implantable Cardioverter-Defibrillator Therapy in Brugada Syndrome A 20-Year Single-Center Experience
    Conte, Giulio
    Sieira, Juan
    Ciconte, Giuseppe
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    Baltogiannis, Giannis
    Di Giovanni, Giacomo
    La Meir, Mark
    Wellens, Francis
    Czapla, Jens
    Wauters, Kristel
    Levinstein, Moises
    Saitoh, Yukio
    Irfan, Ghazala
    Julia, Justo
    Pappaert, Gudrun
    Brugada, Pedro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (09) : 879 - 888
  • [49] Real-life outcome of implantable cardioverter-defibrillator and cardiac resynchronization defibrillator replacement/upgrade in a contemporary population: observations from the multicentre DECODE registry
    Biffi, Mauro
    Ammendola, Ernesto
    Menardi, Endrj
    Parisi, Quintino
    Narducci, Maria Lucia
    De Filippo, Paolo
    Manzo, Michele
    Stabile, Giuseppe
    Potenza, Domenico Rosario
    Zanon, Francesco
    Quartieri, Fabio
    Rillo, Mariano
    Saporito, Davide
    Zaca, Valerio
    Berisso, Massimo Zoni
    Bertini, Matteo
    Tumietto, Fabio
    Malacrida, Maurizio
    Diemberger, Igor
    EUROPACE, 2019, 21 (10): : 1527 - 1536
  • [50] The mortality analysis of primary prevention patients receiving a cardiac resynchronization defibrillator (CRT-D) or implantable cardioverter-defibrillator (ICD) according to guideline indications in the improve SCA study
    Ching, Chi Keong
    Hsieh, Yu-Cheng
    Liu, Yen-Bing
    Rodriguez, Diego A.
    Kim, Young-Hoon
    Joung, Boyoung
    Singh, Balbir
    Huang, Dejia
    Hussin, Azlan
    Chasnoits, Alexandr R.
    O'Brien, Janet E.
    Cerkvenik, Jeffrey
    Lexcen, Daniel
    Van Dorn, Brian
    Zhang, Shu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (08) : 2285 - 2294