Bioelectrical impedance underestimates total and truncal fatness in abdominally obese women

被引:96
作者
Neovius, Martin [1 ]
Hemmingsson, Erik [1 ]
Freyschuss, Bo [1 ]
Udden, Joanna [1 ]
机构
[1] Karolinska Univ Hosp, Karolinska Inst, Obes Unit, Dept Med, SE-14186 Stockholm, Sweden
关键词
agreement; bioelectrical impedance analysis; body composition; DXA; women;
D O I
10.1038/oby.2006.199
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare estimates of total and truncal fatness from eight-electrode bioelectrical impedance analysis equipment (BIA(8)) with those from DXA in centrally obese women. The secondary aim was to examine BMI and waist circumference (WC) as proxy measures for percentage total body fat (%TBF) and truncal body fat percentage (tr%BF). Research Methods and Procedures: This was a cross-sectional study of 136 women (age, 48.1 +/- 7.7 years; BMI, 30.4 +/- 2.9 kg /m(2); %TBFDXA, 46.0 +/- 3.7%; WC, 104 +/- 8 cm). Fatness was measured by DXA and Tanita BC-418 equipment (Tanita Corp., Tokyo, Japan). Agreement among methods was assessed by Bland-Altman plots, and regression analysis was used to evaluate anthropometric measures as proxies for total and abdominal fatness. Results: The percentage of overweight subjects was 41.9%, whereas 55.9% of the subjects were obese, as defined by BMI, and all subjects had a WC exceeding the World Health Organization cut-off point for abdominal obesity. Compared with DXA, the BIA(8) equipment significantly underestimated total %BF (-5.0; -3.6 to -8.5 [mean; 95% confidence interval]), fat mass (-3.6; -3.9 to -3.2), and tr%BF (-8.5; -9.1 to -7.9). The discrepancies between the methods increased with increasing adiposity for both %TBF and tr%BF (both p < 0.001). Variation in BMI explained 28% of the variation in %TBFDXA and 5 1 % of %TBFBIA8 Using WC as a proxy for truncal adiposity, it explained only 18% of tr%BFDXA variance and 27% of tr%BFDXA variance. The corresponding figures for truncal fat mass were 49% and 35%, respectively. No significant age effects were observed in any of the regressions. Discussion: BIA(8) underestimated both total and truncal fatness, compared with DXA, with higher dispersion for tr%BF than %TBF. The discrepancies increased with degree of adiposity, suggesting that the accuracy of BIA is negatively affected by obesity.
引用
收藏
页码:1731 / 1738
页数:8
相关论文
共 27 条
[1]  
Aleman-Mateo H, 2004, J Nutr Health Aging, V8, P344
[2]  
[Anonymous], 2000, WHO TECH REP SER, V894, pi
[3]  
Bolanowski M, 2001, Med Sci Monit, V7, P1029
[4]  
Brummer RJM, 1996, GROWTH REGULAT, V6, P191
[5]   Underestimation of percentage fat mass measured by bioelectrical impedance analysis compared to dual energy X-ray absorptiometry method in obese children [J].
Eisenkölbl, J ;
Kartasurya, M ;
Widhalm, K .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2001, 55 (06) :423-429
[6]   Assessment of body composition in ballett dancers: Correlation among anthropometric measurements, bio-electrical impedance analysis, and dual-energy X-ray absorptiometry [J].
Eliakim, A ;
Ish-Shalom, S ;
Giladi, A ;
Falk, B ;
Constantini, N .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2000, 21 (08) :598-601
[7]   Comparison of body composition analysis methods in clinical routine [J].
Erselcan, T ;
Candan, F ;
Saruhan, S ;
Ayca, T .
ANNALS OF NUTRITION AND METABOLISM, 2000, 44 (5-6) :243-248
[8]   Body composition, as assessed by bioelectrical impedance spectroscopy and dual-energy X-ray absorptiometry, in a healthy paediatric population [J].
Fors, H ;
Gelander, L ;
Bjarnason, R ;
Albertsson-Wikland, K ;
Bosaeus, I .
ACTA PAEDIATRICA, 2002, 91 (07) :755-760
[9]   Validity and reliability of dual-energy X-ray absorptiometry for the assessment of abdominal adiposity [J].
Glickman, SG ;
Marn, CS ;
Supiano, MA ;
Dengel, DR .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (02) :509-514
[10]   Body composition profiles of elite American heptathletes [J].
Houtkooper, LB ;
Mullins, VA ;
Going, SB ;
Brown, CH ;
Lohman, TG .
INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2001, 11 (02) :162-173