Immunohistochemical detection of CD10 in paraffin sections of hematopoietic neoplasms - A comparison with flow cytometry detection in 56 cases

被引:18
作者
Chu, PG [1 ]
Chang, KL [1 ]
Weiss, LM [1 ]
Arber, DA [1 ]
机构
[1] City Hope Natl Med Ctr, Div Pathol, Duarte, CA 91010 USA
关键词
CD10; clone; 56C6; immunohistochemistry; flow cytometry; acute lymphoblastic leukemia; follicular lymphoma;
D O I
10.1097/00022744-200012000-00001
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Paraffin-section immunohistochemistry with heat-induced epitope retrieval using a newly characterized monoclonal antibody (clone 56C6) against the CD10 antigen was performed on 56 hematopoietic tumors previously studied for CD10 expression by flow cytometry. The cases included 33 precursor B-lymphoblastic leukemias, 10 acute myeloid leukemias, five precursor T-lymphoblastic leukemias, five follicular lymphomas, and three Burkitt cell leukemias. Forty of the 56 cases were CD10 positive by flow cytometry studies, including all five follicular lymphomas (100%); 30 of 33 (91%) cases of precursor B-lymphoblastic leukemias, two of three (66%) cases of Burkitt cell leukemias, two of five (40%) cases of precursor T-lymphoblastic leukemias, and none of the 10 cases of acute myeloid leukemia. Thirty-nine of the 40 (97%) flow cytometric CD10-positive cases also expressed CD10 by immunohistochemistry in formalin- or B5-fixed, paraffin-embedded tissue, with only one case of precursor B-lymphoblastic leukemia being positive by flow cytometry and negative by immunohistochemistry. The 16 CD10-negative flow cytometry specimens were all also negative by immunohistochemistry. Thirty-seven CD10 immunohistochemistry positive cases showed a diffuse membranous staining pattern and two cases demonstrated a Golgi staining pattern. The fixation methods (10% neutral buffered formalin versus B5) and decalcification did not affect the CD10 immunostaining results. This study demonstrates that the new CD10 monoclonal antibody clone 56C6 is a reliable marker for detection of CD10 antigen expression in formalin- and B5-fixed paraffin-embedded tissue after heat-induced epitope retrieval when compared with flow cytometry detection of fresh tissue samples.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 26 条
[1]   CD10 - A review [J].
Arber, DA ;
Weiss, LM .
APPLIED IMMUNOHISTOCHEMISTRY & MOLECULAR MORPHOLOGY, 1997, 5 (03) :125-140
[2]  
BRAUN MP, 1983, BLOOD, V61, P718
[3]   CANDIDATE LEUKEMIA-SPECIFIC ANTIGEN IN MAN [J].
BROWN, G ;
HOGG, N ;
GREAVES, M .
NATURE, 1975, 258 (5534) :454-456
[4]   LEUKEMIA-ASSOCIATED ANTIGENS IN MAN [J].
BROWN, G ;
CAPELLARO, D ;
GREAVES, M .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1975, 55 (06) :1281-1289
[5]   Paraffin-section detection of CD10 in 505 nonhematopoietic neoplasms - Frequent expression in renal cell carcinoma and endometrial stromal sarcoma [J].
Chu, PG ;
Arber, DA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2000, 113 (03) :374-382
[6]  
GOWN AM, 1993, APPL IMMUNOHISTO M M, V1, P256
[7]  
GREAVES MF, 1983, BLOOD, V61, P628
[8]   ANTISERA TO ACUTE LYMPHOBLASTIC LEUKEMIA-CELLS [J].
GREAVES, MF ;
BROWN, G ;
RAPSON, NT ;
LISTER, TA .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1975, 4 (01) :67-84
[9]  
GREGORY CD, 1987, J IMMUNOL, V139, P313
[10]   World Health Organization classification of neoplastic diseases of the hematopoietic and lymphoid tissues: Report of the Clinical Advisory Committee Meeting - Airlie House, Virginia, November 1997 [J].
Harris, NL ;
Jaffe, ES ;
Diebold, J ;
Flandrin, G ;
Muller-Hermelink, HK ;
Vardiman, J ;
Lister, TA ;
Bloomfield, CD .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (12) :3835-3849