Comparison of QT Interval Readings in Normal Sinus Rhythm Between a Smartphone Heart Monitor and a 12-Lead ECG for Healthy Volunteers and Inpatients Receiving Sotalol or Dofetilide

被引:77
作者
Garabelli, Paul [1 ,2 ]
Stavrakis, Stavros [1 ,2 ]
Albert, Michael [1 ,2 ]
Koomson, Edward [1 ,2 ]
Parwani, Purvi [1 ,2 ]
Chohan, Jawad [1 ,2 ]
Smith, Landgrave [3 ]
Albert, David [3 ]
Xie, Rongsheng [1 ,2 ]
Xie, Qiying [1 ,2 ]
Reynolds, Dwight [1 ,2 ]
Po, Sunny [1 ,2 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Sect Cardiovasc Dis, Oklahoma City, OK USA
[2] Univ Oklahoma, Hlth Sci Ctr, Heart Rhythm Inst, 1200 Everett Dr,Room 6E103, Oklahoma City, OK 73106 USA
[3] AliveCor, Oklahoma City, OK USA
关键词
dofetilide QT; QTc; sotalol; DE-POINTES; PROLONGATION; TORSADE; LEAD;
D O I
10.1111/jce.12976
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
QT Interval Readings With a Smartphone Heart Monitor IntroductionA variety of medications ranging from antiarrhythmics to psychotropics, as well as conditions such as bradycardia, can prolong the QT interval, increasing the risk for life-threatening arrhythmias. Monitoring the corrected QT interval (QTc) is therefore critical for patient safety. The recent development of smart phone heart monitors (SHM) may allow for easier QTc monitoring. We sought to evaluate the accuracy of an SHM for assessing the QTc, as compared to the standard 12-lead ECG. Methods and ResultsWe compared the QTc interval in lead-I and lead-II between an SHM and 12-lead ECG. Healthy volunteers and hospitalized patients in sinus rhythm being loaded on dofetilide or sotalol were included. Manual and automatic measurements were studied. Across 99 healthy volunteers, the SHM QTc demonstrated good agreement (bias = 4 milliseconds, standard deviation of bias = 11 milliseconds) compared to the 12-lead ECG, using the Bland-Altman method of agreement. Across all hospitalized patients, the SHM was capable of demonstrating QTc prolongation. Between the 12-lead ECG and SHM, lead-I measurements had reasonable agreement (bias = 3 milliseconds, standard deviation of bias = 46 milliseconds). A QTc of > 500 milliseconds was associated with a higher likelihood (OR = 12.0; 95% CI 1.5-111.4; P = 0.02) to not achieve perfect agreement. ConclusionThe SHM is accurate in measuring QTc interval in sinus rhythm when compared to 12-lead ECG in healthy volunteers. For patients receiving QT prolonging antiarrhythmics, SHM is capable of detecting QTc prolongation, and lead-I of the SHM is most accurate in measuring the QTc if < 500 milliseconds.
引用
收藏
页码:827 / 832
页数:6
相关论文
共 22 条
  • [1] What clinicians should know about the QT interval
    Al-Khatib, SM
    LaPointe, NMA
    Kramer, JM
    Califf, RM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (16): : 2120 - 2127
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] QT interval and antidepressant use: a cross sectional study of electronic health records
    Castro, Victor M.
    Clements, Caitlin C.
    Murphy, Shawn N.
    Gainer, Vivian S.
    Fava, Maurizio
    Weilburg, Jeffrey B.
    Erb, Jane L.
    Churchill, Susanne E.
    Kohane, Isaac S.
    Iosifescu, Dan V.
    Smoller, Jordan W.
    Perlis, Roy H.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2013, 346
  • [4] Chung EH, 2015, J ELECTROCARDIOL, V48, P8, DOI 10.1016/j.jelectrocard.2014.10.005
  • [5] Which lead for Q-T interval measurements?
    Davey, PP
    [J]. CARDIOLOGY, 2000, 94 (03) : 159 - 164
  • [6] Predicting the degree of drug-induced QT prolongation and the risk for torsades de pointes
    Ding, Chunhua
    [J]. HEART RHYTHM, 2011, 8 (10) : 1535 - 1536
  • [7] Drew BJ, 2010, J AM COLL CARDIOL, V55, P934, DOI [10.1016/j.jacc.2010.01.001, 10.1161/CIRCULATIONAHA.109.192704]
  • [8] Prolonged QT Interval Diagnosis Suppression by a Widely Used Computerized ECG Analysis System
    Garg, Anubhav
    Lehmann, Michael H.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) : 76 - 83
  • [9] QT interval: How to measure it and what is "normal"
    Goldenberg, I
    Moss, AJ
    Zareba, W
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (03) : 333 - 336
  • [10] Wireless Smartphone ECG Enables Large-Scale Screening in Diverse Populations
    Haberman, Zachary C.
    Jahn, Ryan T.
    Bose, Rupan
    Tun, Han
    Shinbane, Jerold S.
    Doshi, Rahul N.
    Chang, Philip M.
    Saxon, Leslie A.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (05) : 520 - 526