Effects of Mechanical Performance on Deliverability and Dose Distribution by Comparing Multi Institutions' Knowledge-based Models for Prostate Cancer in Volumetric Modulated Arc Therapy

被引:2
|
作者
Tsuru, Haruhi [1 ,2 ]
Ueda, Yoshihiro [1 ]
Tamura, Mikoto [3 ]
Monzen, Hajime [3 ]
Ohira, Shingo [1 ]
Masaoka, Akira [1 ]
Inui, Shouki [1 ,2 ]
Konishi, Koji [1 ]
Fukunaga, Junichi [4 ]
Mizuno, Hirokazu [5 ]
Miyazaki, Masayoshi [1 ]
Koizumi, Masahiko [2 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Dept Med Phys & Engn, Grad Sch Med, Osaka, Japan
[3] Kindai Univ, Dept Med Phys, Grad Sch Med Sci, Osaka, Japan
[4] Kyushu Univ Hosp, Div Radiol, Dept Med Technol, Fukuoka, Japan
[5] Osaka Rosai Hosp, Div Cent Radiol, Osaka, Japan
来源
IN VIVO | 2022年 / 36卷 / 02期
关键词
Knowledge-based planning; multi models; MCSv; RapidPlan; PLANS; IMRT; VMAT; HEAD;
D O I
10.21873/invivo.12754
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: The aim of this study was to evaluate the mechanical performance and the effect on dose distribution and deliverability of volumetric modulated arc therapy (VMAT) plans for prostate cancer created with the commercial knowledge-based planning (KBP) system (RapidPlan (TM)). Materials and Methods: Three institutions, A, B, and C were enrolled in this study. Each institution established and trained a KBP model with their own cases. CT data and structures for 45 patients at institution B were utilized to validate the dose-volume parameters (D-2(%), D-95(%), and D-98(%) for target, and V-50(%), V-75(%), and V-90(%) for rectum and bladder), and the following mechanical performance parameters and gamma passing rates of each KBP model: leaf sequence variability (LSV), aperture area variability (AAV), total monitor unit (MU), modulation complexity score for VMAT (MCSv), MU/control point (CP), aperture area (AA)/CP, and MUxAA/CP. Results: Significant differences (p<0.01) in dosimetric parameters such as D-2 and D-98 for target and V-50, V-75, and V-90 for bladder were observed among the three institutions. The means and standard deviations of MCSv were 0.31 +/- 0.03, 0.29 +/- 0.02, and 0.32 +/- 0.03, and the angles of maximum and minimum MUxAA/CP were 269 degrees and 13 degrees, 269 degrees and 13 degrees, and 273 degrees and 153 degrees at institutions A, B, and C, respectively. The mean gamma passing rate (1%/1 mm.) was >95% for all cases in each institution. Dose distribution and mechanical performance significantly differed between the three models. Conclusion: Each KBP model had different dose distributions and mechanical performance but could create an acceptable plan for deliverability regardless of mechanical performance.
引用
收藏
页码:687 / 693
页数:7
相关论文
共 50 条
  • [41] Megavoltage X-Ray Volumetric Modulated Arc Therapy and Multi-Entrance Three Dimensional Conformal Radiation Therapy for Prostate Cancer
    Assaoui, F.
    Lachgar, A.
    Benjaafar, N.
    AFRICAN REVIEW OF PHYSICS, 2020, 15 : 177 - 183
  • [42] Automatic genetic planning for volumetric modulated arc therapy: A large multi-centre validation for prostate cancer
    Fiandra, Christian
    Rossi, Linda
    Alparone, Alessandro
    Zara, Stefania
    Vecchi, Claudio
    Sardo, Anna
    Bartoncini, Sara
    Loi, Gianfranco
    Pisani, Carla
    Gino, Eva
    Redda, Maria Grazia Ruo
    Deotto, Gian Marco
    Tini, Paolo
    Comi, Stefania
    Zerini, Dario
    Ametrano, Gianluca
    Borzillo, Valentina
    Strigari, Lidia
    Strolin, Silvia
    Savini, Alessandro
    Romeo, Antonino
    Reccanello, Sonia
    Abu Rumeileh, Imad
    Ciscognetti, Nunzia
    Guerrisi, Flavia
    Balestra, Gabriella
    Ricardi, Umberto
    Heijmen, Ben
    RADIOTHERAPY AND ONCOLOGY, 2020, 148 : 126 - 132
  • [43] The effect of bladder contrast on dose calculation in volumetric modulated arc therapy planning in patients treated for postoperative prostate cancer
    Tülay Ercan
    Şefik İğdem
    Gül Alço
    Japanese Journal of Radiology, 2016, 34 : 376 - 382
  • [44] Multi-institutional comparison of computer-based independent dose calculation for intensity modulated radiation therapy and volumetric modulated arc therapy
    Kamima, Tatsuya
    Baba, Hiromi
    Takahashi, Ryo
    Yamashita, Mikiko
    Sugawara, Yasuharu
    Kawai, Daisuke
    Yamamoto, Toshijiro
    Satou, Aya
    Tachibana, Hidenobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 72 - 81
  • [45] Dose escalation (81 Gy) with image-guided radiation therapy and volumetric-modulated arc therapy for localized prostate cancer: A retrospective preliminary result
    Huang, Sheng-Yao
    Wu, Chen-Ta
    Liu, Dai-Wei
    Wang, Tzu-Hwei
    Liao, Yen-Hsiang
    Chen, Yi-Wei
    Hsu, Wen-Lin
    TZU CHI MEDICAL JOURNAL, 2020, 32 (01): : 75 - 81
  • [46] The effects of intestinal air cavity on dose distribution of volume modulated arc therapy for cervical cancer
    Chang, Xiaobin
    Yuan, Yuan
    Wang, Guoqing
    Hu, Lijuan
    Zhou, Min
    Liu, Huijuan
    Pan, Libo
    Wang, Jing
    ANNALS OF PALLIATIVE MEDICINE, 2022, 11 (04) : 1326 - 1335
  • [47] A retrospective planning analysis comparing intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) using two optimization algorithms for the treatment of early-stage prostate cancer
    Elith, Craig A.
    Dempsey, Shane E.
    Warren-Forward, Helen M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2013, 60 (03): : 84 - 92
  • [48] On the pre-clinical validation of a commercial model-based optimisation engine: Application to volumetric modulated arc therapy for patients with lung or prostate cancer
    Fogliata, Antonella
    Belosi, Francesca
    Clivio, Alessandro
    Navarria, Piera
    Nicolini, Giorgia
    Scorsetti, Marta
    Vanetti, Eugenio
    Cozzi, Luca
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) : 385 - 391
  • [49] Training and validation of a knowledge-based dose-volume histogram predictive model in the optimisation of intensity-modulated proton and volumetric modulated arc photon plans for pleural mesothelioma patients
    Franceschini, Davide
    Cozzi, Luca
    Fogliata, Antonella
    Marini, Beatrice
    Di Cristina, Luciana
    Dominici, Luca
    Spoto, Ruggero
    Franzese, Ciro
    Navarria, Pierina
    Comito, Tiziana
    Reggiori, Giacomo
    Tomatis, Stefano
    Scorsetti, Marta
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [50] Training and validation of a knowledge-based dose-volume histogram predictive model in the optimisation of intensity-modulated proton and volumetric modulated arc photon plans for pleural mesothelioma patients
    Davide Franceschini
    Luca Cozzi
    Antonella Fogliata
    Beatrice Marini
    Luciana Di Cristina
    Luca Dominici
    Ruggero Spoto
    Ciro Franzese
    Pierina Navarria
    Tiziana Comito
    Giacomo Reggiori
    Stefano Tomatis
    Marta Scorsetti
    Radiation Oncology, 17