Cataract quantification using swept-source optical coherence tomography

被引:22
|
作者
Bras, Joao E. G. [1 ]
Sickenberger, Wolfgang [1 ]
Hirnschall, Nino [2 ]
Findl, Oliver [2 ]
机构
[1] Ernst Abbe Hsch Jena, JenVis Res GbR, SciTec Dept, Jena, Germany
[2] Hanusch Hosp, Ophthalmol Dept, Vienna Inst Res Ocular Surg, Vienna, Austria
来源
关键词
SCHEIMPFLUG IMAGING-SYSTEM; LENS OPACITIES; DENSITOMETRY;
D O I
10.1016/j.jcrs.2018.08.009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop and evaluate a cataract quantification method using a swept-source optical coherence tomography (SS-OCT) device (IOLMaster 700). Setting: Hanusch Hospital, Vienna, Austria. Design: Prospective multicenter case series. Methods: This study included patients with cataract in at least 1 eye. Two independent examiners performed Lens Opacities Classification System II (LOOS II) grading at the slitlamp independently. Corrected distance visual acuity, contrast sensitivity, and SS-OCT measurements were also performed. In addition, the phacoemulsification energy and time were recorded. To develop an objective SS-OCT-based cataract quantification system, all SS-OCT scans were segmented and the local pixel intensity unit of the lens was analyzed using Matlab's grayscale counting. The pixel intensity unit of the lens nucleus (OCT-based cataract quantification system score) was equated to the clinician's subjective nuclear opalescence grading. Results: The study evaluated 186 eyes (113 patients). The correlation between the independent examiners' LOCS grading was good (0.91) (P<.01). The correlation between the LOCS grading and OCT-based cataract quantification system score was 0.86 for examiner 1 and 0.76 for examiner 2 (both P<.01). In 24 patients, phacoemulsification time, power, and energy; visual acuity; and contrast sensitivity were available and included in the study. The OCT-based cataract quantification system scores correlated significantly with phacoemulsification time (0.71) and energy (0,64) (both P<.01). Conclusions: Cataract density could be evaluated using an SS-OCT device, and the OCT-based cataract quantification system values correlated with the conventional LOCS II classification. Swept-source OCT measurements allowed quantification and documentation cataract density. (C) 2018 ASCRS and ESCRS
引用
收藏
页码:1478 / 1481
页数:4
相关论文
共 50 条
  • [1] Cataract quantification using swept-source optical coherence tomography
    Panthier, Christophe
    Saad, Main
    Rouger, Helene
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 893 - 894
  • [2] Cataract quantification using swept-source optical coherence tomography Reply
    Findl, Oliver
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 894 - 894
  • [3] Commentary: Efficacy of swept-source optical coherence tomography in dense cataract
    Malik, Robin
    Singh, Atul Kumar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 112 - 113
  • [4] Objective quantification of posterior capsule opacification after cataract surgery with swept-source optical coherence tomography
    Zhou, Yu
    Xiang, Jing
    Xu, Fang
    Jiang, Ziyuan
    Liu, Fang
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [5] Objective quantification of posterior capsule opacification after cataract surgery with swept-source optical coherence tomography
    Yu Zhou
    Jing Xiang
    Fang Xu
    Ziyuan Jiang
    Fang Liu
    BMC Ophthalmology, 23
  • [6] Normal and Cataract Crystalline Lens Evaluation with Swept-Source Optical Coherence Tomography
    De Castro, Alberto
    Benito, Antonio
    Manzanera, Silvestre
    Mompean, Juan
    Canizares, Belen
    Maria Marin, Jose
    Grulkowski, Ireneusz
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [7] "Diamond wire mesh" appearance of cataract on swept-source optical coherence tomography
    Delhiwala, K.
    Shah, K.
    Khamar, B.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (08): : 992 - 993
  • [8] Average lens density quantification with swept-source optical coherence tomography: optimized, automated cataract grading technique
    Panthier, Christophe
    de Wazieres, Alice
    Rouger, Helene
    Moran, Sarah
    Saad, Alain
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (12): : 1746 - 1752
  • [9] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [10] Quantification of choroidal hyperreflective layer: A swept-source optical coherence tomography study
    Ahn, So Min
    Song, Myung-Sun
    Togloom, Ariunaa
    Oh, Jaeryung
    PLOS ONE, 2023, 18 (11):