Electrochemical Sensor Based on Oxidation of 2,8-Dihydroxyadenine to Monitor DNA Damage in Calf Thymus DNA

被引:2
作者
Goyal, Rajendra N. [1 ]
Chatterjee, Sanghamitra [1 ]
Rana, Anoop Raj Singh [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
Calf thymus DNA; 2,8-Dihydroxyadenine; Edge plane pyrolytic graphite electrode; Single-wall carbon nanotubes; Square wave voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; PYROLYTIC-GRAPHITE ELECTRODE; PURINE METABOLISM; CARBON NANOTUBES; ACID; ADENINE; VOLTAMMETRY; CHEMISTRY; URINE; HPLC;
D O I
10.1002/elan.201000753
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and reliable direct electrochemical method has been established to monitor DNA damage in acid hydrolyzed calf thymus DNA, based on the determination of 2,8-dihydroxyadenine (2,8-DHA). A single-wall carbon nanotubes (SWCNT) modified edge plane pyrolytic graphite electrode (EPPGE) has been used as a sensor to monitor the DNA damage. 2,8-DHA the main in vivo adenine oxidation product undergoes oxidation at similar to 395 mV at SWCNT modified EPPGE using square wave voltammetry (SWV). The sensor exhibits potent and persistent electron-mediating behavior. A well-defined oxidation peak for the oxidation of 2,8-DHA was observed at modified electrode with lowering of peak potential and increase in peak current as compared to bare EPPGE. At optimal experimental conditions, the catalytic oxidative peak current was responsive with the 2,8-DHA concentrations ranging from 0.05 nM to 100 nM. The detection limit was 3.8 x 10(-11) M and limit of quantification was 1.27 x 10(-10) M. The modified electrode exhibited high stability and reproducibility.
引用
收藏
页码:1383 / 1390
页数:8
相关论文
共 46 条
  • [41] Cyclic voltammetry on electrode surfaces covered with porous layers: An analysis of electron transfer kinetics at single-walled carbon nanotube modified electrodes
    Streeter, Ian
    Wildgoose, Gregory G.
    Shao, Lidong
    Compton, Richard G.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (02): : 462 - 466
  • [42] AUTOMATED SCREENING SYSTEM FOR PURINE AND PYRIMIDINE METABOLISM DISORDERS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SUMI, S
    KIDOUCHI, K
    OHBA, S
    WADA, Y
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 672 (02): : 233 - 239
  • [43] FREE-RADICAL DNA ADDUCT 8-OH-DEOXYGUANOSINE AFFECTS ACTIVITY OF HPA-II AND MSP-I RESTRICTION ENDONUCLEASES
    TURK, PW
    WEITZMAN, SA
    [J]. FREE RADICAL RESEARCH, 1995, 23 (03) : 255 - 258
  • [44] Biological consequences of free radical-damaged DNA bases
    Wallace, SS
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2002, 33 (01) : 1 - 14
  • [45] Determination of purines including 2,8-dihydroxyadenine in urine using capillary electrophoresis
    Wessel, T
    Lanvers, C
    Fruend, S
    Hempel, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 894 (1-2) : 157 - 164
  • [46] Electrochemical Sensing and Biosensing Platform Based on Chemically Reduced Graphene Oxide
    Zhou, Ming
    Zhai, Yueming
    Dong, Shaojun
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (14) : 5603 - 5613