Penetration depth of laser Doppler flowmetry beam in teeth

被引:21
作者
Polat, S [1 ]
Er, K
Polat, NT
机构
[1] Cumhuriyet Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-58140 Sivas, Turkey
[2] Cumhuriyet Univ, Fac Dent, Dept Endodont, TR-58140 Sivas, Turkey
[3] Cumhuriyet Univ, Fac Dent, Dept Prosthet Dent, TR-58140 Sivas, Turkey
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2005年 / 100卷 / 01期
关键词
D O I
10.1016/j.tripleo.2004.11.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of this study was to determine the penetration depth of laser light in teeth for contact and noncontact probe tip. Study design. Fifty-one freshly extracted human mature maxillary and mandibular single rooted teeth were selected for the study. A laser Doppler flowmeter was used as a laser source. A digital camera was used to take pictures (with "night shot" mode in total darkness). When probe tip was in contact and when it was I mm away from the tooth, the depths of the areas illuminated in high and low density were measured. Results. In contact probe, root was illuminated to 4.28 +/- 0.14 mm depth with high density and 13.27 +/- 0.27 mm depth with low, density. In noncontact probe, 4.36 +/- 0.16 mm with high density and 13.28 +/- 0.30 mm with low density of illumination were seen on the root. Between contact and noncontact probe situations the difference was not statistically significant in the depth of illumination. On the other hand, in both groups the difference between areas illuminated in high and low density was statistically significant (P < .05). Conclusion. Contact or noncontact of the probe on tooth surface did not show any significant difference in light penetration. Besides, we think that, for the present, it is impossible to eliminate the contarnination from periodontal tissues completely even if the necessary precautions (periodontal paste etc.) are taken.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 29 条
  • [1] AARS H, 1993, ACTA PHYSIOL SCAND, V148, P441, DOI 10.1111/j.1748-1716.1993.tb09580.x
  • [2] Effect of Gingiva on laser Doppler pulpal blood flow measurements
    Akpinar, KE
    Er, K
    Polat, S
    Polat, NT
    [J]. JOURNAL OF ENDODONTICS, 2004, 30 (03) : 138 - 140
  • [3] Altshuler G.B., 1990, P 1 INT C LASERS MED, VVolume 1353, P97, DOI [10.1117/12.23746, DOI 10.1117/12.23746]
  • [4] AMESS TR, 1993, J PHYSIOL-LONDON, V473, pP142
  • [5] CAKIR S, 2000, BILIM TEKNIK, V397, P34
  • [6] Pulpal blood flow assessed by laser Doppler flowmetry in a tooth with a horizontal root fracture
    Ebihara, A
    Tokita, Y
    Izawa, T
    Suda, H
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1996, 81 (02): : 229 - 233
  • [7] NATURE OF LIGHT-SCATTERING IN DENTAL ENAMEL AND DENTIN AT VISIBLE AND NEAR-INFRARED WAVELENGTHS
    FRIED, D
    GLENA, RE
    FEATHERSTONE, JDB
    SEKA, W
    [J]. APPLIED OPTICS, 1995, 34 (07) : 1278 - 1285
  • [8] GAZELIUS B, 1986, Endodontics and Dental Traumatology, V2, P219
  • [9] Blood-flow and neurosensory changes in the maxillary dental pulp after differing Le Fort I osteotomies
    Harada, K
    Sato, M
    Omura, K
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (01): : 12 - 17
  • [10] Environmental effects on laser Doppler pulpal blood-flow measurements in man
    Hartmann, A
    Azerad, J
    Boucher, Y
    [J]. ARCHIVES OF ORAL BIOLOGY, 1996, 41 (04) : 333 - 339