Numerical Study of the Significance of the Non-Newtonian Nature of Blood in Steady Flow Through a Stenosed Vessel

被引:28
|
作者
Bodnar, Tomas [1 ]
Sequeira, Adelia [1 ]
机构
[1] Czech Tech Univ, Dept Tech Math, Fac Mech Engn, Prague 12135 2, Czech Republic
来源
ADVANCES IN MATHEMATICAL FLUID MECHANICS: DEDICATED TO GIOVANNI PAOLO GALDI ON THE OCCASION OF HIS 60TH BIRTHDAY, INTERNATIONAL CONFERENCE ON MATHEMATICAL FLUID MECHANICS, 2007 | 2010年
关键词
Non-Newtonian fluids; Blood rheology; Stenosis; Numerical simulations; VISCOSITY; SHEAR; VISCOELASTICITY; MODEL;
D O I
10.1007/978-3-642-04068-9_6
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this paper we present a comparative numerical study of non-Newtonian shear-thinning and viscoelastic blood flow models through an idealized stenosis. Three-dimensional numerical simulations are performed using a finite volume semi-discretization in space, on structured grids, and a multistage Runge-Kutta scheme for time integration, to investigate the influence of combined effects of inertia, viscosity and viscoelasticity in this particular geometry. This work lays the foundation for future applications to pulsatile flows in stenosed vessels using constitutive models capturing the rheological response of blood, under relevant physiological conditions.
引用
收藏
页码:83 / +
页数:3
相关论文
共 50 条
  • [31] Mathematical modeling of pulsatile flow of non-Newtonian fluid in stenosed arteries
    Sankar, D. S.
    Lee, Usik
    COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2009, 14 (07) : 2971 - 2981
  • [32] Oxygen transport in pulsatile non-Newtonian fluid through a stenosed artery
    Nagarani, P.
    Job, Victor
    Sankar, Alana
    Gunakala, Sreedhara Rao
    PHYSICS OF FLUIDS, 2025, 37 (02)
  • [33] Non-Newtonian blood flow across stenosed elliptical artery: Case study of nanoparticles for brain disabilities with fuzzy logic
    Shahzad, Muhammad Hasnain
    Ahammad, N. Ameer
    Nadeem, Sohail
    Awan, Aziz Ullah
    Guedri, Kamel
    Alamer, Ahmed
    Fadhl, Bandar M.
    MODERN PHYSICS LETTERS B, 2025, 39 (11):
  • [34] The Numerical Analysis of Non-Newtonian Blood Flow in a Mechanical Heart Valve
    Chen, Aolin
    Basri, Adi Azriff
    Bin Ismail, Norzian
    Ahmad, Kamarul Arifin
    PROCESSES, 2023, 11 (01)
  • [35] Concentric ballooned catheterization to the fractional non-newtonian hybrid nano blood flow through a stenosed aneurysmal artery with heat transfer
    Mehmood, Obaid Ullah
    Bibi, Sehrish
    Jamil, Dzuliana F.
    Uddin, Salah
    Roslan, Rozaini
    Akhir, Mohd Kamalrulzaman Md
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [36] Finite element analysis of non-Newtonian magnetohemodynamic flow conveying nanoparticles through a stenosed coronary artery
    Vasu, B.
    Dubey, Ankita
    Beg, O. Anwar
    HEAT TRANSFER-ASIAN RESEARCH, 2020, 49 (01): : 33 - 66
  • [37] Effects of non-Newtonian properties of blood on flow characteristics through a stenosis
    Moayeri, MS
    Vali, A
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY, 1996, 20 (01): : 25 - 43
  • [38] Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis
    Tian, Fang-Bao
    Zhu, Luoding
    Fok, Pak-Wing
    Lu, Xi-Yun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (09) : 1098 - 1113
  • [39] Numerical simulation of non-Newtonian blood flow dynamics in human thoracic aorta
    Caballero, A. D.
    Lain, S.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (11) : 1200 - 1216
  • [40] Comparative Study of Newtonian Physiological Blood Flow through Normal and Stenosed Carotid Artery
    Rahman, Mohammad Matiur
    Hossain, Md. Anwar
    Mamun, Khairuzzaman
    Akhter, Most. Nasrin
    7TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING (ICTE), 2017, 1851