Clinical suitability of deep learning based synthetic CTs for adaptive proton therapy of lung cancer

被引:26
|
作者
Thummerer, Adrian [1 ]
Oria, Carmen Seller [1 ]
Zaffino, Paolo [2 ]
Meijers, Arturs [1 ]
Marmitt, Gabriel Guterres [1 ]
Wijsman, Robin [1 ]
Seco, Joao [3 ,4 ]
Langendijk, Johannes Albertus [1 ]
Knopf, Antje-Christin [1 ,5 ]
Spadea, Maria Francesca [2 ]
Both, Stefan [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
[2] Magna Graecia Univ Catanzaro, Dept Expt & Clin Med, Catanzaro, Italy
[3] Deutsch Krebsfosch Zentrum DKFZ, Dept Biomed Phys Radiat Oncol, Heidelberg, Germany
[4] Heidelberg Univ, Dept Phys & Astron, Heidelberg, Germany
[5] Univ Hosp Cologne, Ctr Integrated Oncol Cologne, Dept Internal Med 1, Cologne, Germany
关键词
adaptive proton therapy; cone-beam computed tomography; deep learning; lung cancer; synthetic CT; CONE-BEAM CT; HEAD-AND-NECK; DOSE CALCULATION; COMPUTED-TOMOGRAPHY; TECHNICAL NOTE; IMAGE; RADIOTHERAPY; REGISTRATION; FEASIBILITY; RADIOGRAPHY;
D O I
10.1002/mp.15333
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Adaptive proton therapy (APT) of lung cancer patients requires frequent volumetric imaging of diagnostic quality. Cone-beam CT (CBCT) can provide these daily images, but x-ray scattering limits CBCT-image quality and hampers dose calculation accuracy. The purpose of this study was to generate CBCT-based synthetic CTs using a deep convolutional neural network (DCNN) and investigate image quality and clinical suitability for proton dose calculations in lung cancer patients. Methods A dataset of 33 thoracic cancer patients, containing CBCTs, same-day repeat CTs (rCT), planning-CTs (pCTs), and clinical proton treatment plans, was used to train and evaluate a DCNN with and without a pCT-based correction method. Mean absolute error (MAE), mean error (ME), peak signal-to-noise ratio, and structural similarity were used to quantify image quality. The evaluation of clinical suitability was based on recalculation of clinical proton treatment plans. Gamma pass ratios, mean dose to target volumes and organs at risk, and normal tissue complication probabilities (NTCP) were calculated. Furthermore, proton radiography simulations were performed to assess the HU-accuracy of sCTs in terms of range errors. Results On average, sCTs without correction resulted in a MAE of 34 +/- 6 HU and ME of 4 +/- 8 HU. The correction reduced the MAE to 31 +/- 4HU (ME to 2 +/- 4HU). Average 3%/3 mm gamma pass ratios increased from 93.7% to 96.8%, when the correction was applied. The patient specific correction reduced mean proton range errors from 1.5 to 1.1 mm. Relative mean target dose differences between sCTs and rCT were below +/- 0.5% for all patients and both synthetic CTs (with/without correction). NTCP values showed high agreement between sCTs and rCT (<2%). Conclusion CBCT-based sCTs can enable accurate proton dose calculations for APT of lung cancer patients. The patient specific correction method increased the image quality and dosimetric accuracy but had only a limited influence on clinically relevant parameters.
引用
收藏
页码:7673 / 7684
页数:12
相关论文
共 50 条
  • [41] Improved diagnosis of lung cancer classification based on deep learning method
    Feroui, Amel
    Saim, Meriem
    Lazouni, Mohammed El Amine
    Lazzouni, Sihem Amel
    Elaouaber, Zineb Aziza
    Messadi, Mahammed
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2024, 46 (02) : 138 - 159
  • [42] Dosimetric influence of deformable image registration uncertainties on propagated structures for online daily adaptive proton therapy of lung cancer patients
    Nenoff, Lena
    Matter, Michael
    Amaya, Enrique Javier
    Josipovic, Mirjana
    Knopf, Antje-Christin
    Lomax, Antony John
    Persson, Gitte F.
    Ribeiro, Cassia O.
    Visser, Sabine
    Walser, Marc
    Weber, Damien Charles
    Zhang, Ye
    Albertini, Francesca
    RADIOTHERAPY AND ONCOLOGY, 2021, 159 : 136 - 143
  • [43] Deep Fuzzy SegNet-based lung nodule segmentation and optimized deep learning for lung cancer detection
    Navaneethakrishnan, M.
    Anand, M. Vijay
    Vasavi, G.
    Rani, V. Vasudha
    PATTERN ANALYSIS AND APPLICATIONS, 2023, 26 (03) : 1143 - 1159
  • [44] Deep Fuzzy SegNet-based lung nodule segmentation and optimized deep learning for lung cancer detection
    M. Navaneethakrishnan
    M. Vijay Anand
    G. Vasavi
    V. Vasudha Rani
    Pattern Analysis and Applications, 2023, 26 (3) : 1143 - 1159
  • [45] Deep reinforcement learning for automated radiation adaptation in lung cancer
    Tseng, Huan-Hsin
    Luo, Yi
    Cui, Sunan
    Chien, Jen-Tzung
    Ten Haken, Randall K.
    El Naqa, Issam
    MEDICAL PHYSICS, 2017, 44 (12) : 6690 - 6705
  • [46] Research on Segmentation Technology in Lung Cancer Radiotherapy Based on Deep Learning
    Huang, Jun
    Liu, Tao
    Qian, Beibei
    Chen, Zhibo
    Wang, Ya
    CURRENT MEDICAL IMAGING, 2023, 19 (11) : 1231 - 1244
  • [47] A 4D-CBCT correction network based on contrastive learning for dose calculation in lung cancer
    Cao, Nannan
    Wang, Ziyi
    Ding, Jiangyi
    Zhang, Heng
    Zhang, Sai
    Gao, Liugang
    Sun, Jiawei
    Xie, Kai
    Ni, Xinye
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [48] CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy
    Reiners, Keaton
    Dagan, Roi
    Holtzman, Adam
    Bryant, Curtis
    Andersson, Sebastian
    Nilsson, Rasmus
    Hong, Liu
    Johnson, Perry
    Zhang, Yawei
    CANCERS, 2023, 15 (15)
  • [49] Current status of proton therapy techniques for lung cancer
    Han, Youngyih
    RADIATION ONCOLOGY JOURNAL, 2019, 37 (04): : 232 - 248
  • [50] Feasibility of Continual Deep Learning-Based Segmentation for Personalized Adaptive Radiation Therapy in Head and Neck Area
    Kim, Nalee
    Chun, Jaehee
    Chang, Jee Suk
    Lee, Chang Geol
    Keum, Ki Chang
    Kim, Jin Sung
    CANCERS, 2021, 13 (04) : 1 - 19