Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis

被引:31
作者
Rezaei, Ahmadreza [1 ]
Deroose, Christophe M. [1 ]
Vahle, Thomas [2 ]
Boada, Fernando [3 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Nucl Med & Mol Imaging, Leuven, Belgium
[2] Siemens Healthcare GmbH, Erlangen, Germany
[3] NYU, Med Ctr, New York, NY 10016 USA
关键词
quantitative analysis; joint reconstruction; time-of-flight PET; TOF-PET; EMISSION; IMAGE; EXTENSION;
D O I
10.2967/jnumed.117.204156
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods for joint activity reconstruction and attenuation reconstruction of time-of-flight (TOF) PET data provide an effective solution to attenuation correction when no (or incomplete or inaccurate) information on attenuation is available. One of the main barriers limiting use of these methods in clinical practice is their lack of validation in a relatively large patient database. In this contribution, we aim to validate reconstruction performed with maximum-likelihood activity reconstruction and attenuation registration (MLRR) in a whole-body patient dataset. Furthermore, a partial validation (because the scale problem of the algorithm is avoided for now) of reconstruction performed with maximum-likelihood activity and attenuation (MLAA) is also provided. We present a quantitative comparison between these 2 methods of joint reconstruction and the current clinical gold standard, maximum-likelihood expectation maximization (MLEM) with CT-based attenuation correction. Methods: The whole-body TOF PET emission data of each patient dataset were processed as a whole to reconstruct an activity volume covering all the acquired bed positions, helping reduce the problem of a scale per bed position in MLAA to a global scale for the entire activity volume. Three reconstruction algorithms were used: MLEM, MLRR, and MLAA. A maximum-likelihood scaling of the single-scatter simulation estimate to the emission data was used for scatter correction. The reconstruction results for various regions of interest were then analyzed. Results: The joint reconstructions of the whole-body patient dataset provided better quantification than the gold standard in cases of PET and CT misalignment caused by patient or organ motion. Our quantitative analysis showed a difference of -4.2% +/- 2.3% between MLRR and MLEM and a difference of -7.5% +/- 4.6% between MLAA and MLEM, averaged over all regions of interest. Conclusion: Joint reconstruction of activity and attenuation provides a useful means to estimate tracer distribution when CTbased- attenuation images are subject to misalignment or are not available. With an accurate estimate of the scatter contribution in the emission measurements, the joint reconstructions of TOF PET data are within clinically acceptable accuracy.
引用
收藏
页码:1630 / 1635
页数:6
相关论文
共 50 条
  • [21] State of the art and challenges of time-of-flight PET
    Conti, Maurizio
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01): : 1 - 11
  • [22] Impact of Time-of-Flight on PET Tumor Detection
    Kadrmas, Dan J.
    Casey, Michael E.
    Conti, Maurizio
    Jakoby, Bjoern W.
    Lois, Cristina
    Townsend, David W.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) : 1315 - 1323
  • [23] Update on latest advances in time-of-flight PET
    Surti, Suleman
    Karp, Joel S.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 251 - 258
  • [24] An MLEM Method for Joint Tissue Activity Distribution and Photon Attenuation Map Reconstruction in PET
    Mihlin, Alexander
    Levin, Craig S.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [25] Focus on time-of-flight PET: the benefits of improved time resolution
    Conti, Maurizio
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) : 1147 - 1157
  • [26] Focus on time-of-flight PET: the benefits of improved time resolution
    Maurizio Conti
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 1147 - 1157
  • [27] Simultaneous Reconstruction of Activity and Attenuation for PET/MR
    Salomon, Andre
    Goedicke, Andreas
    Schweizer, Bernd
    Aach, Til
    Schulz, Volkmar
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 804 - 813
  • [28] Benefit of time-of-flight in PET: Experimental and clinical results
    Karp, Joel S.
    Surti, Sulernan
    Daube-Witherspoon, Margaret E.
    Muehllehner, Gerd
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (03) : 462 - 470
  • [29] New prospects for time-of-flight PET with LSO scintillators
    Moszynski, M.
    Kapusta, M.
    Nassalski, A.
    Szczesnaik, T.
    Wolski, D.
    Eriksson, L.
    Melcher, C. L.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2854 - 2858
  • [30] New prospects for time-of-flight PET with LSO scintillators
    Moszynski, M.
    Kapusta, M.
    Nassalski, A.
    Szczesniak, T.
    Wolski, D.
    Eriksson, L.
    Melcher, C. L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2484 - 2488