Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis

被引:31
作者
Rezaei, Ahmadreza [1 ]
Deroose, Christophe M. [1 ]
Vahle, Thomas [2 ]
Boada, Fernando [3 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Nucl Med & Mol Imaging, Leuven, Belgium
[2] Siemens Healthcare GmbH, Erlangen, Germany
[3] NYU, Med Ctr, New York, NY 10016 USA
关键词
quantitative analysis; joint reconstruction; time-of-flight PET; TOF-PET; EMISSION; IMAGE; EXTENSION;
D O I
10.2967/jnumed.117.204156
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods for joint activity reconstruction and attenuation reconstruction of time-of-flight (TOF) PET data provide an effective solution to attenuation correction when no (or incomplete or inaccurate) information on attenuation is available. One of the main barriers limiting use of these methods in clinical practice is their lack of validation in a relatively large patient database. In this contribution, we aim to validate reconstruction performed with maximum-likelihood activity reconstruction and attenuation registration (MLRR) in a whole-body patient dataset. Furthermore, a partial validation (because the scale problem of the algorithm is avoided for now) of reconstruction performed with maximum-likelihood activity and attenuation (MLAA) is also provided. We present a quantitative comparison between these 2 methods of joint reconstruction and the current clinical gold standard, maximum-likelihood expectation maximization (MLEM) with CT-based attenuation correction. Methods: The whole-body TOF PET emission data of each patient dataset were processed as a whole to reconstruct an activity volume covering all the acquired bed positions, helping reduce the problem of a scale per bed position in MLAA to a global scale for the entire activity volume. Three reconstruction algorithms were used: MLEM, MLRR, and MLAA. A maximum-likelihood scaling of the single-scatter simulation estimate to the emission data was used for scatter correction. The reconstruction results for various regions of interest were then analyzed. Results: The joint reconstructions of the whole-body patient dataset provided better quantification than the gold standard in cases of PET and CT misalignment caused by patient or organ motion. Our quantitative analysis showed a difference of -4.2% +/- 2.3% between MLRR and MLEM and a difference of -7.5% +/- 4.6% between MLAA and MLEM, averaged over all regions of interest. Conclusion: Joint reconstruction of activity and attenuation provides a useful means to estimate tracer distribution when CTbased- attenuation images are subject to misalignment or are not available. With an accurate estimate of the scatter contribution in the emission measurements, the joint reconstructions of TOF PET data are within clinically acceptable accuracy.
引用
收藏
页码:1630 / 1635
页数:6
相关论文
共 50 条
  • [1] Practical joint reconstruction of activity and attenuation with autonomous scaling for time-of-flight PET
    Li, Yusheng
    Matej, Samuel
    Karp, Joel S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [2] A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET
    Zhang, Haiqiong
    Wang, Jingnan
    Li, Nan
    Zhang, Yue
    Cui, Jie
    Huo, Li
    Zhang, Hui
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [3] A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET
    Haiqiong Zhang
    Jingnan Wang
    Nan Li
    Yue Zhang
    Jie Cui
    Li Huo
    Hui Zhang
    BMC Medical Imaging, 23
  • [4] Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Rezaei, Ahmadreza
    Nuyts, Johan
    Defrise, Michel
    Bal, Girish
    Michel, Christian
    Conti, Maurizio
    Watson, Charles
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2375 - 2382
  • [5] Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object
    Garcia-Perez, Pablo
    Espana, Samuel
    EJNMMI PHYSICS, 2020, 7 (01)
  • [6] A Quantitative Evaluation of Joint Activity and Attenuation Reconstruction in TOF PET/MR Brain Imaging
    Rezaei, Ahmadreza
    Schramm, Georg
    Willekens, Stefanie M. A.
    Delso, Gaspar
    Van Laere, Koen
    Nuyts, Johan
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (11) : 1649 - 1655
  • [7] Simultaneous emission and attenuation reconstruction in time-of-flight PET using a reference object
    Pablo García-Pérez
    Samuel España
    EJNMMI Physics, 7
  • [8] Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI
    Mehranian, Abolfazl
    Arabi, Hossein
    Zaidi, Habib
    NEUROIMAGE, 2016, 130 : 123 - 133
  • [9] Effect of attenuation mismatches in time of flight PET reconstruction
    Emond, Elise C.
    Bousse, Alexandre
    Machado, Maria
    Porter, Joanna
    Groves, Ashley M.
    Hutton, Brian F.
    Thielemans, Kris
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (08)
  • [10] Improving time resolution in time-of-flight PET
    Conti, Maurizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S194 - S198