Energy use and thermal comfort in a rammed earth office building

被引:89
作者
Taylor, P. [1 ]
Fuller, R. J. [2 ]
Luther, M. B. [2 ]
机构
[1] Charles Sturt Univ, Div Facil Management, Albury, NSW 2640, Australia
[2] Deakin Univ, Sch Architecture & Bldg, Built Environm Res Grp, Geelong, Vic 3217, Australia
关键词
rammed earth; thermal comfort; energy; office building;
D O I
10.1016/j.enbuild.2007.05.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A two-storey rammed earth building was built on the Thurgoona Campus of Charles Sturt University in Albury-Wodonga, Australia, in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes an evaluation of the building in terms of measured thermal comfort and energy use. Measurements, confirmed by a staff questionnaire, found the building was too hot in summer and too cold in winter. Comparison with another office building in the same location found that the rammed earth building used more energy for heating. The thermal performance of three offices in the rammed earth building was investigated further using simulation to predict office temperatures. Comparisons were made with measurements made over typical weeks in summer and winter. The validated model has been used to investigate key building parameters and strategies to improve the thermal comfort and reduce energy consumption in the building. Simulations showed that improvements could be made by design and control strategy changes. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:793 / 800
页数:8
相关论文
共 50 条
[41]   Advances in the building materials for thermal comfort and energy saving [J].
Kumar, Arun ;
Singh, O.P. .
Recent Patents on Engineering, 2013, 7 (03) :220-232
[42]   Low embodied energy cement stabilised rammed earth building-A case study [J].
Reddy, B. V. Venkatarama ;
Leuzinger, Georg ;
Sreeram, V. S. .
ENERGY AND BUILDINGS, 2014, 68 :541-546
[43]   Experimental Confirmation of the Reliability of Fanger's Thermal Comfort ModelCase Study of a Near-Zero Energy Building (NZEB) Office Building [J].
Piasecki, Michal ;
Fedorczak-Cisak, Malgorzata ;
Furtak, Marcin ;
Biskupski, Jacek .
SUSTAINABILITY, 2019, 11 (09)
[44]   Window Operation and Its Impacts on Thermal Comfort and Energy Use [J].
Wang, Liping .
PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 :259-266
[45]   ASSESSMENT OF THERMAL COMFORT PREFERENCES IN MEDITERRANEAN CLIMATE A University Office Building Case [J].
Turhan, Cihan ;
Gokcen Akkurt, Gulden .
THERMAL SCIENCE, 2018, 22 (05) :2177-2187
[46]   Thermal Comfort in a Greened Office Building: Investigation and Evaluation through Measurement and Survey [J].
Hollands, Jutta ;
Sesto, Eldira ;
Korjenic, Azra .
SUSTAINABILITY, 2022, 14 (21)
[47]   Thermal comfort evaluation in a mechanically ventilated office building located in a continental climate [J].
Soutullo, S. ;
Enriquez, R. ;
Jimenez, M. J. ;
Heras, M. R. .
ENERGY AND BUILDINGS, 2014, 81 :424-429
[48]   The Effect of Demand Response on Perceived Thermal Comfort in a District Heated Office Building [J].
Salo, Sonja ;
Jokisalo, Juha ;
Syri, Sanna ;
Kosonen, Risto .
2018 15TH INTERNATIONAL CONFERENCE ON THE EUROPEAN ENERGY MARKET (EEM), 2018,
[49]   Effects of Thermostat Control on Energy Use and Thermal Comfort in Office Rooms Under Different Glazing Ratio [J].
Wang, Haiying ;
Hou, Rongfu ;
Olesen, Bjarne W. ;
Kazanci, Ongun B. ;
Lin, Huxiang .
BUILDINGS, 2025, 15 (14)
[50]   Mutual Influence of External Wall Thermal Transmittance, Thermal Inertia, and Room Orientation on Office Thermal Comfort and Energy Demand [J].
Bozicek, David ;
Kunic, Roman ;
Krainer, Ales ;
Stritih, Uros ;
Dovjak, Mateja .
ENERGIES, 2023, 16 (08)