Energy use and thermal comfort in a rammed earth office building

被引:84
作者
Taylor, P. [1 ]
Fuller, R. J. [2 ]
Luther, M. B. [2 ]
机构
[1] Charles Sturt Univ, Div Facil Management, Albury, NSW 2640, Australia
[2] Deakin Univ, Sch Architecture & Bldg, Built Environm Res Grp, Geelong, Vic 3217, Australia
关键词
rammed earth; thermal comfort; energy; office building;
D O I
10.1016/j.enbuild.2007.05.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A two-storey rammed earth building was built on the Thurgoona Campus of Charles Sturt University in Albury-Wodonga, Australia, in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes an evaluation of the building in terms of measured thermal comfort and energy use. Measurements, confirmed by a staff questionnaire, found the building was too hot in summer and too cold in winter. Comparison with another office building in the same location found that the rammed earth building used more energy for heating. The thermal performance of three offices in the rammed earth building was investigated further using simulation to predict office temperatures. Comparisons were made with measurements made over typical weeks in summer and winter. The validated model has been used to investigate key building parameters and strategies to improve the thermal comfort and reduce energy consumption in the building. Simulations showed that improvements could be made by design and control strategy changes. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:793 / 800
页数:8
相关论文
共 50 条
  • [11] Predictive Heating Control and Perceived Thermal Comfort in a Norwegian Office Building
    Lolli, Nicola
    Gorantonaki, Evgenia
    Clauss, John
    [J]. ENERGIES, 2024, 17 (15)
  • [12] A Review on Adaptive Thermal Comfort of Office Building for Energy-Saving Building Design
    Lamsal, Prativa
    Bajracharya, Sushil Bahadur
    Rijal, Hom Bahadur
    [J]. ENERGIES, 2023, 16 (03)
  • [13] Evaluating the Building Performance of an Office Building in London to Improve Indoor Thermal Comfort
    Elsharkawy, Heba
    Zahiri, Sahar
    [J]. SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 3, 2018, : 978 - 979
  • [14] An Atlas for Rammed Earth Building Thermal Performance in Australia Climates
    Chen, Dong
    Ren, Zhengen
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 3823 - 3830
  • [15] Building Integrated Shading and Building Applied Photovoltaic System Assessment in the Energy Performance and Thermal Comfort of Office Buildings
    Martinopoulos, Georgios
    Serasidou, Anna
    Antoniadou, Panagiota
    Papadopoulos, Agis M.
    [J]. SUSTAINABILITY, 2018, 10 (12)
  • [16] THE THERMAL BEHAVIOUR OF RAMMED EARTH WALL IN TRADITIONAL HOUSE IN VOJVODINA Thermal Mass as a Key Element for Thermal Comfort
    Lovec, Vesna B.
    Jovanovic-Popovic, Milica Dj.
    Zivkovic, Branislav D.
    [J]. THERMAL SCIENCE, 2018, 22 : S1143 - S1155
  • [17] Building with earth rammed: pool in Toro
    Antelo Tudela, Enrique
    Sanchez Iglesias, Santiago
    Crespo Gonzalez, Cristobal
    Raya de Blas, Antonio
    [J]. BOLETIN ACADEMICO-REVISTA DE INVESTIGACION Y ARQUITECTURA CONTEMPORANEA, 2012, (02): : 27 - 35
  • [18] Thermal comfort and energy use
    Stegou-Sagia, A
    Antonopoulos, KA
    Angelopoulou, C
    [J]. Proceedings of ECOS 2005, Vols 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS, 2005, : 911 - 918
  • [19] Personalized Thermal Comfort Model for a Multiple Occupancy Office Building
    Patchava, Raviteja
    Lee, JeeHee
    [J]. COMPUTING IN CIVIL ENGINEERING 2023-RESILIENCE, SAFETY, AND SUSTAINABILITY, 2024, : 824 - 830
  • [20] Design Criteria to Reduce Energy Demand and Improve Thermal Comfort in Desert-coastal Climate Office-building
    Matias Tapia-Maureira, Cristopher
    Piderit Moreno, Maria Beatriz
    [J]. 34TH INTERNATIONAL CONFERENCE ON PASSIVE AND LOW ENERGY ARCHITECTURE: SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT, VOL 2 (PLEA 2018), 2018, : 676 - 681