Design and field-weakening performance of a synchronous reluctance motor with axially laminated rotor

被引:33
|
作者
Chalmers, BJ [1 ]
Musaba, L [1 ]
机构
[1] Univ Manchester, Inst Sci & Technol, Dept Elect Engn & Elect, Manchester M60 1QD, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
axially laminated rotor; field weakening; synchronous reluctance motor;
D O I
10.1109/28.720443
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Axially laminated reluctance motors can be designed to have high saliency and so offer very good performance in terms of torque capacity, power factor, and efficiency. This paper presents the design and performance of a 7.5-kW four-pole machine, using thin rotor laminations, which achieved an unsaturated saliency ratio of 12.5. Finite-element analysis is used to predict machine parameters, paying special attention to modeling of the thin rotor elements and to saturation effect on the d axis, Computed parameters are compared with test measurements, showing good agreement. Load tests with 50-Hz supply confirm the expected performance characteristics, but also show the occurrence of additional losses associated with the axially laminated rotor construction. A design modification to reduce the extra losses is demonstrated, A detailed investigation of field-weakening performance is reported, showing constant-power characteristics and good agreement between predicted and measured performance over a speed range of 2.25:1 above base speed.
引用
收藏
页码:1035 / 1041
页数:7
相关论文
共 50 条
  • [1] Design and field-weakening performance of a synchronous reluctance motor with axially laminated rotor
    Univ of Manchester, Manchester, United Kingdom
    IEEE Trans Ind Appl, 5 (1035-1041):
  • [2] Design and field-weakening performance of a synchronous reluctance motor with axially-laminated rotor.
    Chalmers, BJ
    Musaba, L
    IAS '97 - CONFERENCE RECORD OF THE 1997 IEEE INDUSTRY APPLICATIONS CONFERENCE / THIRTY-SECOND IAS ANNUAL MEETING, VOLS 1-3, 1997, : 271 - 278
  • [3] Design and field-weakening performance of permanent-magnet/reluctance motor with two-part rotor
    Chalmers, BJ
    Akmese, R
    Musaba, L
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1998, 145 (02): : 133 - 139
  • [4] Design optimisation of an axially laminated synchronous reluctance motor
    Coates, CE
    Platt, D
    Perera, BSP
    IAS '97 - CONFERENCE RECORD OF THE 1997 IEEE INDUSTRY APPLICATIONS CONFERENCE / THIRTY-SECOND IAS ANNUAL MEETING, VOLS 1-3, 1997, : 279 - 285
  • [5] Impact of the Current Vector Angle on the Performance of a Synchronous Reluctance Motor With an Axially Laminated Anisotropic Rotor
    Abramenko, Valerii
    Petrov, Ilya
    Nerg, Janne
    Pyrhonen, Juha
    IEEE ACCESS, 2021, 9 : 102609 - 102622
  • [6] Performance analysis of axially laminated anisotropic synchronous reluctance motor
    Saxena, Ravi
    Banerji, G. K.
    Srivastava, Ajay
    Rawat, H. S.
    CHALLENGES IN POWER, HIGH VOLTAGES AND MACHINES: PROCEEDINGS OF THE 7TH WSEAS INTERNATIONAL CONFERENCE ON ELECTRIC POWER SYSTEMS, HIGH VOLTAGES, ELECTRIC MACHINES (POWER '07), 2007, : 97 - +
  • [7] A synchronous reluctance motor with a laminated rotor
    Litvinov B.V.
    Davydenko O.B.
    Russian Electrical Engineering, 2009, 80 (1) : 29 - 32
  • [8] Analytical model of the synchronous reluctance motor with axially laminated rotor for optimization purpose
    Torac, Ileana
    Argeseanu, Alin
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL II A AND B, 2008, : 27 - +
  • [9] Robust Direct Torque Control of Synchronous Reluctance Motor Drives in the Field-Weakening Region
    Foo, Gilbert Hock Beng
    Zhang, Xinan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (02) : 1289 - 1298
  • [10] FIELD-WEAKENING PERFORMANCE OF BRUSHLESS SYNCHRONOUS AC MOTOR-DRIVES
    SOONG, WL
    MILLER, TJE
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1994, 141 (06): : 331 - 340