Au@Zr-based metal-organic framework composite as an immunosensing platform for determination of hepatitis B virus surface antigen

被引:15
作者
Bajpai, Vivek K. [1 ]
Haldorai, Yuvraj [2 ]
Khan, Imran [3 ]
Sonwal, Sonam [4 ]
Singh, Mahendra Pal [5 ]
Yadav, Seema [6 ]
Paray, Bilal Ahamad [7 ]
Jan, Basit Latief [8 ]
Kang, Sung-Min [9 ]
Huh, Yun Suk [4 ]
Han, Young-Kyu [1 ]
Shukla, Shruti [10 ]
机构
[1] Dongguk Univ, Dept Energy & Mat Engn, 30 Pildong Ro 1 Gil, Seoul 04620, South Korea
[2] Bharathiar Univ, Dept Nanosci & Technol, Coimbatore 641046, Tamil Nadu, India
[3] Univ Minnesota, Hormel Inst, 801 16th Ave NE, Austin, MN 55912 USA
[4] Inha Univ, Nanobio High Tech Mat Res Ctr, Dept Biol Sci & Bioengn, Incheon 22212, South Korea
[5] Mayo Clin, Dept Immunol, Rochester, MN 55905 USA
[6] Yeungnam Univ, Dept Civil Engn, Gyongsan 38541, Gyeongbuk, South Korea
[7] King Saud Univ, Coll Sci, Dept Zool, POB 2455, Riyadh 11451, Saudi Arabia
[8] King Saud Univ, Coll Pharm, Dept Clin Pharm, POB 2455, Riyadh 11451, Saudi Arabia
[9] Sangmyung Univ, Dept Green Chem Engn, Cheonan 31066, Chungnam, South Korea
[10] Energy & Resources Inst, TERI Deakin Nanobiotechnol Ctr, Gurugram 122003, Haryana, India
关键词
Immunosensor; Hepatitis B; Electrochemical sensing; Voltammetry; Composite glassy carbon electrode; Immunofunctionalized Au@UiO-66(NH2); Au nanoparticles; HBsAg; ELECTROCHEMICAL IMMUNOSENSOR; ULTRASENSITIVE DETECTION; SENSITIVE IMMUNOSENSOR; NANOPOROUS GOLD; IMMUNOASSAY; NANOCOMPOSITE; NANOPARTICLE; OXIDATION; SYSTEM; SENSOR;
D O I
10.1007/s00604-021-05022-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive electrochemical immunosensor has been prepared using an immunofunctionalized zirconium (Zr)-based metal-organic framework (MOF) with gold (Au) decoration Au@UiO-66(NH2) composite-coated glassy carbon electrode (GCE) for the determination of infectious hepatitis B surface antigen (HBsAg). We fabricated GCE with specific composite via immune-functionalization using anti-HBsAg with Au nanoparticles embedded in UiO-66(NH2). The electrochemical sensing performance of the immunofunctionalized Au@UiO-66(NH2)/GCE with HBsAg was characterized by cyclic voltammetry and differential pulse voltammetry. Under optimized conditions, there was a linear dynamic relationship in the buffer system between the electrical signal and HBsAg levels over the range 1.13 fg mL(-1)-100 ng mL(-1) (R-2 = 0.999) with a detection limit of 1.13 fg mL(-1). The total analysis time was 15 min per sample. Further validations were performed with HBsAg-spiked human serum samples, and similar detection limits as in the buffer system were observed with reduced signal intensities at lower concentrations of HBsAg (1, 10, and 100 fg mL(-1)) and minimal interference. The HBsAg electrochemical immunosensing assay had good selectivity and excellent reproducibility, thereby indicating its significant potential in the super-fast diagnosis of hepatitis B.
引用
收藏
页数:13
相关论文
共 49 条
[1]   Gold nanoparticle-decorated reduced-graphene oxide targeting anti hepatitis B virus core antigen [J].
Abd Muain, Mohamad Farid ;
Cheo, Kooi Hoong ;
Omar, Muhamad Nadzmi ;
Hamzah, Amir Syahir Amir ;
Lim, Hong Ngee ;
Salleh, Abu Bakar ;
Tan, Wen Siang ;
Tajudin, Asilah Ahmad .
BIOELECTROCHEMISTRY, 2018, 122 :199-205
[2]   Amplified detection of hepatitis B virus using an electrochemical DNA biosensor on a nanoporous gold platform [J].
Ahangar, Laleh Enayati ;
Mehrgardi, Masoud A. .
BIOELECTROCHEMISTRY, 2017, 117 :83-88
[3]   Development of a multiplex immunochromatographic strip test and ultrasensitive electrochemical immunosensor for hepatitis B virus screening [J].
Akkapinyo, Chutimon ;
Khownarumit, Porntip ;
Waraho-Zhmayev, Dujduan ;
Poo-arporn, Rungtiva P. .
ANALYTICA CHIMICA ACTA, 2020, 1095 :162-171
[4]   Comparative analysis of single-walled and multi-walled carbon nanotubes for electrochemical sensing of glucose on gold printed circuit boards [J].
Alhans, Ruby ;
Singh, Anukriti ;
Singhal, Chaitali ;
Narang, Jagriti ;
Wadhwa, Shikha ;
Mathur, Ashish .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 90 :273-279
[5]   Electrochemically-deposited PANI on iron mesh-based metal-organic framework with enhanced visible-light response towards elimination of thiamphenicol and E. coli [J].
An, Jibin ;
Li, Yanlin ;
Chen, Wei ;
Li, Guoqiang ;
He, Jiahong ;
Feng, Huixia .
ENVIRONMENTAL RESEARCH, 2020, 191
[6]   A self-enhanced ECL-RET immunosensor for the detection of CA19-9 antigen based on Ru(bpy)2(phen-NH2)2+ - Amine-rich nitrogen-doped carbon nanodots as probe and graphene oxide grafted hyperbranched aromatic polyamide as platform [J].
Bahari, Delnia ;
Babamiri, Bahareh ;
Salimi, Abdollah ;
Hallaj, Rahman ;
Amininasab, S. Mojtaba .
ANALYTICA CHIMICA ACTA, 2020, 1132 :55-65
[7]   Beyond graphene: Electrochemical sensors and biosensors for biomarkers detection [J].
Bollella, Paolo ;
Fusco, Giovanni ;
Tortolini, Cristina ;
Sanzo, Gabriella ;
Favero, Gabriele ;
Gorton, Lo ;
Antiochia, Riccarda .
BIOSENSORS & BIOELECTRONICS, 2017, 89 :152-166
[8]   A label-free electrochemical immunosensor for hepatitis B based on hyaluronic acid-carbon nanotube hybrid film [J].
Cabral, Diego G. A. ;
Lima, Erika C. S. ;
Moura, Patricia ;
Dutra, Rosa F. .
TALANTA, 2016, 148 :209-215
[9]   Liquid gated ZnO nanorod FET sensor for ultrasensitive detection of Hepatitis B surface antigen with vertical electrode configuration [J].
Chakraborty, B. ;
Ghosh, S. ;
Das, N. ;
RoyChaudhuri, C. .
BIOSENSORS & BIOELECTRONICS, 2018, 122 :58-67
[10]   Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection [J].
Chowdhury, Ankan Dutta ;
Takemura, Kenshin ;
Li, Tian-Cheng ;
Suzuki, Tetsuro ;
Park, Enoch Y. .
NATURE COMMUNICATIONS, 2019, 10 (1)