Assessment of Left Ventricular Volumes and Function by Real Time Three-Dimensional Echocardiography in a Pediatric Population: A TomTec versus QLAB Comparison

被引:34
作者
Hascoet, Sebastien [1 ]
Brierre, Gilles [1 ]
Caudron, Guillaume [1 ]
Cardin, Christelle [1 ]
Bongard, Vanina [2 ]
Acar, Philippe [1 ]
机构
[1] Ctr Hosp Univ Toulouse, Dept Paediat Cardiol, Hop Enfants, 330 Ave Grande Bretagne, F-31000 Toulouse, France
[2] Ctr Hosp Univ Toulouse, Dept Epidemiol, UMR INSERM 558, F-31000 Toulouse, France
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2010年 / 27卷 / 10期
关键词
real time 3D echocardiography; TomTec; QLAB; left ventricular function; CARDIAC MAGNETIC-RESONANCE; 2-DIMENSIONAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; BORDER DETECTION; DATA-ACQUISITION; QUANTIFICATION; QUANTITATION; ACCURACY; CHILDREN;
D O I
10.1111/j.1540-8175.2010.01235.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Three-dimensional echocardiography (3DE) allows accurate calculation of ventricular volumes despite a remaining geometric assumption on the ventricular shape. Few studies involving full volume reconstruction software have been performed on children. Our aim was to compare the left ventricular (LV) volume measurements obtained with the most used 3D analysis software in a pediatric population. Methods: Fifty patients (median age: 9.5 years) without cardiac disease were included in the study. 3DE was performed with the X4-2 or X7-2 matrix probe (ie33, Philips). The LV volume analysis was performed with QLAB 6.0 (semiautomated border detection) and TomTec 4D LV (primary manual tracking with semiautomated border detection). Results: TomTec analysis feasibility amounted to 94% whereas QLAB analysis feasibility only reached 80% (P = 0.037). The analysis time was shorter with QLAB than TomTec (5 +/- 2 versus 6 +/- 3 minutes, P < 0.05). The stroke volume, end diastolic and end systolic LV volume measurements performed on the 40 patients were strongly correlated (r > 0.97; P < 0.0001) with minimal bias. The LV ejection fraction was well correlated (r = 0.79; P < 0.0001). Conclusion: 3D LV volume quantification is feasible either by using manual or automated reconstruction software in a normal pediatric population. LV Measurements are well correlated. Differences in volume reconstruction algorithms provide specific software performance characteristics. TomTec is a more feasible method but requires a longer analysis time. Further studies are needed to validate the accuracy of the method to calculate enlarged LV volumes in patients with congenital heart diseases. (Echocardiography 2010;27:1263-1273).
引用
收藏
页码:1263 / 1273
页数:11
相关论文
共 50 条
  • [41] Quantitative Assessment of Left Ventricle by Real-time Three-dimensional Echocardiography
    Lin, Lung-Chun
    Liau, Chiau-Suong
    Lee, Yuan-Teh
    JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (01) : 19 - 30
  • [42] Fast Data Acquisition and Analysis with Real Time Triplane Echocardiography for the Assessment of Left Ventricular Size and Function: A Validation Study
    Nucifora, Gaetano
    Badano, Luigi P.
    Dall'Armellina, Erica
    Gianfagna, Pasquale
    Allocca, Giuseppe
    Fioretti, Paolo M.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (01): : 66 - 75
  • [43] Assessment of the Developmental Change in the Left Atrial Volume Using Real Time Three-Dimensional Echocardiography
    Tanaka, Noboru
    Takigiku, Kiyohiro
    Takahashi, Ken
    Kuraoka, Ayako
    Matsui, Kotoko
    Iwashima, Satoru
    Nii, Masaki
    Toyono, Manatomo
    Takeuchi, Masaaki
    Kishiro, Masahiko
    Yasukochi, Satoshi
    Shimizu, Toshiaki
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (07): : 1131 - 1139
  • [44] Three-dimensional echocardiography to assess left ventricular geometry and function
    Guta, Andrada C.
    Badano, Luigi P.
    Ochoa-Jimenez, Roberto C.
    Genovese, Davide
    Previtero, Marco
    Civera, Stefania
    Ruocco, Alessandro
    Bettella, Natascia
    Parati, Gianfranco
    Muraru, Denisa
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2019, 17 (11) : 801 - 815
  • [45] Assessment of left ventricular systolic synchronicity by real-time three-dimensional echocardiography in patients with dilated cardiomyopathy
    Zeng Xin
    Shu Xian-Hong
    Pan Cui-Zhen
    Chen Rui-Zhen
    Cheng Kuan
    Liu Shi-Zhen
    Chen Hao-Zhu
    CHINESE MEDICAL JOURNAL, 2006, 119 (11) : 919 - 924
  • [47] A multicenter study of three-dimensional echocardiographic evaluation of normal pediatric left ventricular volumes and function
    Jone, Pei-Ni
    Le, Lisa
    Pan, Zhaoxing
    Colen, Tim
    Shigemitsu, Sachie
    Khoo, Nee S.
    Goot, Benjamin H.
    Parthiban, Anitha
    Harrild, David M.
    Ferraro, Alessandra M.
    Marx, Gerald
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (04): : 641 - 645
  • [48] Quantitative assessment of left ventricular size and function in cardiac transplant recipients: Side-by-side comparison of real time two-dimensional echocardiography, contrast-enhanced two-dimensional echocardiography, three-dimensional echocardiography, and contrast-enhanced three-dimensional echocardiography as compared to magnetic resonance imaging
    Rodriguez-Manero, Moises
    Azcarate-Aguero, Pedro
    Kreidieh, Bahij
    Teresa Alvez, Maria
    Martinez-Monzonis, Amparo
    Diaz-Dorronsoro, Agnes
    Cid-Menendez, Adrian
    Ramon Gonzalez-Juanatey, Jose
    Barba-Cosials, Joaquin
    Rabago, Gregorio
    Bastarrika, Gorka
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (02): : 306 - 311
  • [49] Calculation of Pediatric Left Ventricular Mass: Validation and Reference Values Using Real-Time Three-Dimensional Echocardiography
    Laser, Kai Thorsten
    Houben, Britta Anna
    Koerperich, Hermann
    Haas, Nikolaus Alexander
    Kelter-Kloepping, Andrea
    Barth, Peter
    Burchert, Wolfgang
    DallaPozza, Robert
    Kececioglu, Deniz
    Herberg, Ulrike
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (03) : 275 - 283
  • [50] Comparison Between Direct Volumetric and Speckle Tracking Methodologies for Left Ventricular and Left Atrial Chamber Quantification by Three-Dimensional Echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (07) : 1038 - 1044