Determining Significant Elevation of Intraocular Pressure Using Self-tonometry

被引:9
作者
Huang, Jessie [1 ,2 ]
Phu, Jack [1 ,2 ]
Kalloniatis, Michael [1 ,2 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Kensington, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Kensington, NSW, Australia
关键词
CENTRAL CORNEAL THICKNESS; OPEN-ANGLE GLAUCOMA; REBOUND TONOMETER; BIOMECHANICAL PROPERTIES; PROSTAGLANDIN ANALOGS; APPLANATION TONOMETRY; ETHNIC-DIFFERENCES; DIURNAL-VARIATION; ACCURACY; EYE;
D O I
10.1097/OPX.0000000000001478
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE The purpose of this study was to use a large patient cohort to develop a practical, analytical tool for interpreting Icare HOME measurements with respect to applanation pressure. METHODS IOP measurements using the Icare HOME and an applanation tonometer were taken prospectively in 498 consecutive patients. Bland-Altman, frequency distribution, and linear regression analysis were applied to determine measurement differences. A novel criterion, Threshold Icare HOME IOP, was developed to assist identification of elevation above target applanation pressure, considering the expected diurnal variation and measurement variability. RESULTS Icare HOME tended to underestimate applanation tonometry (mean bias, -1.7 mmHg; 95% limits of agreement, -7.0 to +3.6). Overall, differences were within +/- 3 mmHg in 71.5% and +/- 5 mmHg in 92% of patients. Based on the novel criterion developed, Icare HOME measurements that exceed target applanation pressure by 6 mmHg or greater are generally outside the 95% limit of expected observations. CONCLUSIONS The Threshold Icare HOME IOP is a novel and practical criterion that can assist clinicians in their interpretation of Icare HOME phasing measurements with respect to target applanation pressures. Elevation above the expected thresholds may prompt closer monitoring or even modifications to glaucoma management.
引用
收藏
页码:86 / 93
页数:8
相关论文
共 50 条
[41]   Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo [J].
McCafferty, Sean ;
Levine, Jason ;
Schwiegerling, Jim ;
Enikov, Eniko T. .
BMC OPHTHALMOLOGY, 2017, 17
[42]   Comparison of the corrected intraocular pressure by tonopachy with that of Goldmann applanation tonometry in normal and glaucomatous patients [J].
Velis, Girish ;
Kavitha, Srinivasan ;
Zebardast, Nazlee ;
Sengupta, Sabyasachi ;
Venkatesh, Rengaraj .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (04) :620-626
[43]   Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry [J].
Li, Yuehua ;
Shi, Jingming ;
Duan, Xuanchu ;
Fan, Fang .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (12) :1765-1770
[44]   Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma [J].
Ehrlich, Joshua R. ;
Radcliffe, Nathan M. ;
Shimmyo, Mitsugu .
BMC OPHTHALMOLOGY, 2012, 12
[45]   Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry [J].
Luebke, Jan ;
Bryniok, L. ;
Neuburger, M. ;
Jordan, J. F. ;
Boehringer, D. ;
Reinhard, T. ;
Wecker, T. ;
Anton, A. .
INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) :2517-2521
[46]   Evaluation of agreement between intraocular pressure measurements using Goldmann applanation tonometry and Goldmann correlated intraocular pressure by Reichert's ocular response analyser [J].
Ehrlich, J. R. ;
Haseltine, S. ;
Shimmyo, M. ;
Radcliffe, N. M. .
EYE, 2010, 24 (10) :1555-1560
[47]   Determination of Intraocular Pressure in Clinically Healthy Turkish Eastern Anatolian Red Cattle of Different Age Groups Using Rebound Tonometry [J].
Yakan, S. ;
Isler, C. T. ;
Denk, H. .
ISRAEL JOURNAL OF VETERINARY MEDICINE, 2021, 76 (04) :150-155
[48]   Impact of corneal parameters on intraocular pressure measurements in different tonometry methods [J].
Aleksandra Zakrzewska ;
Marta P.Wi?cek ;
Anna Machalińska .
International Journal of Ophthalmology, 2019, (12) :1853-1858
[49]   Intraocular pressure measurement in mice: a comparison between Goldmann and rebound tonometry [J].
C Y Kim ;
M H Kuehn ;
M G Anderson ;
Y H Kwon .
Eye, 2007, 21 :1202-1209
[50]   Effects of Intravenous Detomidine on Intraocular Pressure Readings Obtained by Applanation Tonometry in Clinically Normal Horses [J].
Trbolova, Alexandra ;
Ghaffari, Masoud Selk .
JOURNAL OF EQUINE VETERINARY SCIENCE, 2013, 33 (03) :182-185