Physiological modulation of gait variables by an active partial body weight support system

被引:16
作者
Franz, Jason R.
Glauser, Matthias
Riley, Patrick O.
Della Croce, Ugo
Newton, Frederic
Allaire, Paul E.
Kerrigan, D. Casey
机构
[1] Univ Virginia, Dept Phys Med & Rehabil, Charlottesville, VA USA
[2] Univ Virginia, Charles L Brown Dept Elect & Comp Engn, Charlottesville, VA USA
[3] Univ Sassari, Dept Biomed Sci, I-07100 Sassari, Italy
[4] Univ Virginia, Dept Mech & Aerosp Engn, Charlottesville, VA USA
关键词
body weight support; gait; rehabilitation; treadmill training;
D O I
10.1016/j.jbiomech.2007.04.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Partial body weight support (PBWS) systems used for rehabilitation status post-neurological and musculoskeletal pathologies and injuries are traditionally passive. Our purpose was to demonstrate the ability of an actively controlled PBWS system to provide a clinically relevant modulated support condition while investigating the impact of such a condition on the dynamics of gait. Using an instrumented treadmill and a motion capture system, we compared gait parameters of six healthy young adults (age 24-31 years) during unsupported walking to those under the assistance of two support conditions (a constant 20% body weight support, and a modulated support providing 20% body weight support during the loading response of each leg while allowing for an unsupported terminal stance). The modulated condition achieved support synchronized to gait cycle events with mean and maximum loading errors at the 20% body weight support level equal to 1.01 and 2.44kg, respectively. Constant support significantly reduced sagittal plane hip angle range of motion and increased ankle platartlexion as compared to unsupported walking (p<0.05). Also, a clear trend of decreased stride length was observed for constant support. No significant differences in these parameters were evident between the modulated support condition and unsupported walking. Ankle power generation and absorption both significantly decreased under constant support. The modulated support condition significantly increased ankle power absorption though showed no change in ankle power generation. The ability of the presented active PBWS device to provide individualized support schemes may offer new and possibly improved applications of PBWS rehabilitation. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3244 / 3250
页数:7
相关论文
共 23 条
[1]   Optimal outcomes obtained with body-weight support combined with treadmill training in stroke subjects [J].
Barbeau, H ;
Visintin, M .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (10) :1458-1465
[2]  
CAVAGNA GA, 1963, J APPL PHYSIOL, V181, P1
[3]   An overview of treadmill locomotor training with partial body weight support: A neurophysiologically sound approach whose time has come for randomized clinical trials [J].
Dobkin, BH .
NEUROREHABILITATION AND NEURAL REPAIR, 1999, 13 (03) :157-165
[4]   Spinal cord control of movement: Implications for locomotor rehabilitation following spinal cord injury [J].
Field-Fote, EC .
PHYSICAL THERAPY, 2000, 80 (05) :477-484
[5]   A novel mechatronic body weight support system [J].
Frey, Martin ;
Colombo, Gery ;
Vaglio, Martino ;
Bucher, Rainer ;
Joerg, Matthias ;
Riener, Robert .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (03) :311-321
[6]   Partial body weight support with treadmill locomotion to improve gait after incomplete spinal cord injury: A single-subject experimental design [J].
Gardner, MB ;
Holden, MK ;
Leikauskas, JM ;
Richard, RL .
PHYSICAL THERAPY, 1998, 78 (04) :361-374
[7]   WARD: A pneumatic system for body weight relief in gait rehabilitation [J].
Gazzani, F ;
Fadda, A ;
Torre, M ;
Macellari, V .
IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (04) :506-513
[8]  
GORDON KE, 2000, IMPORTANCE USING APP
[9]   TREADMILL TRAINING WITH PARTIAL BODY-WEIGHT SUPPORT COMPARED WITH PHYSIOTHERAPY IN NONAMBULATORY HEMIPARETIC PATIENTS [J].
HESSE, S ;
BERTELT, C ;
JAHNKE, MT ;
SCHAFFRIN, A ;
BAAKE, P ;
MALEZIC, M ;
MAURITZ, KH .
STROKE, 1995, 26 (06) :976-981
[10]   MEASURED VERSUS PREDICTED VERTICAL DISPLACEMENT OF THE SACRUM DURING GAIT AS A TOOL TO MEASURE BIOMECHANICAL GAIT PERFORMANCE [J].
KERRIGAN, DC ;
VIRAMONTES, BE ;
CORCORAN, PJ ;
LARAIA, PJ .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1995, 74 (01) :3-8