Characterization of Scintillators by Modern Photomultipliers-A New Source of Errors

被引:47
作者
Moszynski, Marek [1 ]
Szczesniak, Tomasz [1 ]
Kapusta, Maciej
Szawlowski, Marek [1 ]
Iwanowska, Joanna [1 ]
Gierlik, Michal [1 ]
Syntfeld-Kazuch, Agnieszka [1 ]
Swiderski, Lukasz [1 ]
Melcher, Chuck L. [2 ]
Eriksson, Lars A. [3 ]
Glodo, Jarek
机构
[1] Soltan Inst Nucl Studies, PL-05400 Otwock, Poland
[2] Univ Tennessee, Sci & Engn Facil, Knoxville, TN 37996 USA
[3] Siemens Med Solut, Knoxville, TN 37932 USA
关键词
BGO; light output of scintillators; LSO; LYSO; photoelectron number; photomultipliers; single photoelectron peak; space charge in photomultipliers; LIGHT YIELD; TOF PET;
D O I
10.1109/TNS.2010.2054111
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The observed discrepancy in the light output, measured for a number of LSO, LYSO and BGO scintillators by different photomultipliers (PMTs), triggered studies to understand the problem. For that purpose the photoelectron number was measured by two different methods: the direct one based on a comparison of the full energy peak to that of the single photoelectron and by a method based on the pulse height resolution of the peak due to the light pulser. In this study, a significant number of different PMTs from Photonis and Hamamatsu were used. We concluded that the number of photoelectrons measured by means of the direct method was higher than the number of photoelectrons calculated from the pulse height resolution of the light pulser peak for all of the PMTs but XP2020Q. It leads to a large dispersion in the estimated light output for a given scintillator. In detail, the light output of BGO and LSO determined with the R6231 and R2059 PMTs is comparable to those measured with XP2020Q PMT and the S3590-18 pin photodiode, when photoelectron number is calculated from the pulse height resolution. Further in-depth studies of the photoelectron number at different bias voltages suggested that the effect is related to the space charge created in the dynode structure of the PMTs. Operation of PMTs at lower bias/gain minimizes this effect; thus, low noise electronics are recommended to determine the single photoelectron peak under these conditions. Moreover, the absolute light output of scintillators is affected by differences in the quantum efficiency calibrations by Photonis and Hamamatsu.
引用
收藏
页码:2886 / 2896
页数:11
相关论文
共 25 条
[1]  
BASZAK J, COMMUNICATION
[2]   TIMING IMPROVED BY THE USE OF DYNODE SIGNALS STUDIED WITH DIFFERENT SCINTILLATORS AND PHOTOMULTIPLIERS [J].
BENGTSON, B ;
MOSZYNSKI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 204 (01) :129-140
[3]  
Bertolaccini M., 1968, Nucl. Electr. Symp., V1, P1
[4]  
*CREM INC, 1912, MOD 112 PREAMPL PURC
[5]   Advances in yield calibration of scintillators [J].
de Haas, Johan T. M. ;
Dorenbos, Pieter .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1086-1092
[6]   Measuring the absolute light yield of scintillators [J].
de Haas, JTM ;
Dorenbos, P ;
van Eijk, CWE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2) :97-100
[7]  
FLYCKT SO, 2002, PHOTONIS PHOTOMULTIP
[8]   Investigation of absolute light output measurement techniques [J].
Gierlik, Michal ;
Moszynski, Marek ;
Nassalski, Antoni ;
Syntfeld-Kazuch, Agnieszka ;
Szczesniak, Tomasz ;
Swiderski, Lukasz .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (04) :1367-1371
[9]   TUKAN - An 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface [J].
Guzik, Z ;
Borsuk, S ;
Traczyk, K ;
Plominski, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :231-235
[10]   A MEASUREMENT OF THE LIGHT YIELD OF COMMON INORGANIC SCINTILLATORS [J].
HOLL, I ;
LORENZ, E ;
MAGERAS, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :105-109