All-reflective multiphoton microscope

被引:14
|
作者
Amirsolaimani, Babak [1 ]
Cromey, Benjamin [1 ]
Peyghambarian, N. [1 ]
Kieu, Khanh [1 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
来源
OPTICS EXPRESS | 2017年 / 25卷 / 19期
基金
美国国家科学基金会;
关键词
FLUORESCENCE MICROSCOPY; GENERATION MICROSCOPY; DISPERSION; OBJECTIVES;
D O I
10.1364/OE.25.023399
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present the design, construction, and characterization of a multiphoton microscope that uses reflective elements for beam shaping and steering. This compact all reflective design removes the adverse effects of dispersion on laser pulse broadening as well as chromatic aberration in the focusing of broadband and multicolored laser sources. The design of this system is discussed in detail, including aberrations analysis via ray-tracing simulation and opto-mechanical design. The resolution of this mirror based all-reflective microscope is characterized using fluorescent microbeads. The performance of the system at multiple wavelengths is investigated along with some potential multiphoton imaging and writing applications. (C) 2017 Optical Society of America
引用
收藏
页码:23399 / 23407
页数:9
相关论文
共 50 条
  • [41] All-reflective spatial and spectral imager improves UV and IR capability
    Overton, G
    LASER FOCUS WORLD, 2005, 41 (10): : 21 - +
  • [42] Michelson-type all-reflective interferometric autocorrelation in the VUV regime
    Gebert, T.
    Rompotis, D.
    Wieland, M.
    Karimi, F.
    Azima, A.
    Drescher, M.
    NEW JOURNAL OF PHYSICS, 2014, 16
  • [43] DUV broadband spectroscopic ellipsometer based on all-reflective focusing optical system
    Song, Guozhi
    Chen, Yaqin
    Liu, Tao
    Cui, Gaozeng
    Wang, Jiandong
    2013 THIRD INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2013, : 492 - 495
  • [44] All-reflective interferometric autocorrelator for the measurement of ultra-short optical pulses
    Mashiko, H
    Suda, A
    Midorikawa, K
    APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (05): : 525 - 530
  • [45] All-reflective interferometric autocorrelator for the measurement of ultra-short optical pulses
    H. Mashiko
    A. Suda
    K. Midorikawa
    Applied Physics B, 2003, 76 : 525 - 530
  • [46] ALL-REFLECTIVE PHASE-SHIFTING MASKS FOR MARKLE-DYSON OPTICS
    HSIEH, RL
    GRENVILLE, A
    OWEN, G
    PEASE, RF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (06): : 3042 - 3046
  • [47] Distortion correction of all-reflective unobscured optical-power zoom objective
    Seidl, Kristof
    Knobbe, Jens
    Schneider, Danilo
    Lakner, Hubert
    APPLIED OPTICS, 2010, 49 (14) : 2712 - 2719
  • [48] AN ALL-REFLECTIVE WIDE-ANGLE FLAT-FIELD TELESCOPE FOR SPACE
    HALLAM, KL
    HOWELL, BJ
    WILSON, ME
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 445 : 295 - 300
  • [49] Design of a compact all-reflective optical system for a CCD remote sensing camera
    Xu, Shiwen
    Fu, Ling
    Xu, Bo
    Long, Funian
    Guangxue Xuebao/Acta Optica Sinica, 2000, 20 (09): : 1268 - 1271
  • [50] All-reflective tethered capsule endoscope for multimodal optical coherence tomography in the esophagus
    Attendu, Xavier
    Bloemen, Paul R.
    Kind, Niels H.
    Faber, Dirk J.
    de Bruin, Daniel M.
    Boudoux, Caroline
    van Leeuwen, Ton G.
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (09)