A comparison of two hyperangulated video laryngoscope blades to direct laryngoscopy in a simulated infant airway: a bicentric, comparative, randomized manikin study

被引:12
作者
Kriege, Marc [1 ]
Pirlich, Nina [1 ]
Ott, Thomas [1 ]
Wittenmeier, Eva [1 ]
Dette, Frank [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Anesthesiol, Langenbeckstr 1, D-55131 Mainz, Germany
来源
BMC ANESTHESIOLOGY | 2018年 / 18卷
关键词
Infant; Airway; Intratracheal intubation; Video laryngoscopy; Pediatric; DIFFICULT TRACHEAL INTUBATION; STANDARD DIRECT LARYNGOSCOPY; CHILDREN LESS-THAN-2 YR; PEDIATRIC INTUBATION; EQUIVALENCE TRIAL; VIDEOLARYNGOSCOPE; GLIDESCOPE(R); REGISTRY; MILLER; MANAGEMENT;
D O I
10.1186/s12871-018-0580-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: In infants, securing the airway is time-critical because of anatomical and physiological differences related to airway management in children less than 1 year old. The aim of this study was to compare the time to ventilation using two different hyperangulated video laryngoscope blades with the time to ventilation via conventional direct laryngoscopy in a normal airway [NA] and in a simulated difficult airway [DA]. Methods: This study was a comparative, bicentric, open-label, randomized controlled evaluation. An infant high-fidelity simulator (SimBaby (TM); Laerdal (R) Medical, Stavanger, Norway) was used, and two scenarios were proposed, as follows: NA and DA evoked with tongue edema and cervical collar. After theoretical and practical briefing, each participant compared in the two airway scenarios the novel King Vision (TM) Pediatric aBlade (KV) (Ambu (R) A/S, Bad Nauheim, Germany) video laryngoscope and the C-MAC (TM) D-blade Ped (DB) (Karl Storz (R) SE & Co. KG, Tuttlingen, Germany) video laryngoscope to conventional laryngoscopy using the Miller Blade (MiB) and the Macintosh Blade (MaB) in a random sequence. Results: Eighty physicians (65 AN and 15 PCCM staff) were included. In the NA scenario, the median [IQR] time to successful time to ventilation (TTV) was significantly shorter for the KV at 13 s [12-15 s] than for the MaB at 14.5 s [13-16 s], DB at 14.5 s [13-16] and MiB at 16 s [14-19] (p < 0.001). In DA, the KV also shortened TTV to 14 s [13-16], whereas TTV was 23 s with the MaB [20-26], 19 s with the DB [16-21], and 27 s with the MiB [22-31] (p < 0.001). There were no differences in first-pass intubation success rates (FPAs) between hyperangulated blades and direct laryngoscopes in NA. In DA, the hyperangulated blades enabled 92 (DB) to 100% (KV) FPAs compared with 65 (MiB) to 76% (MaB) for conventional laryngoscopy (p < 0.001). Conclusion: Video laryngoscopes with hyperangulated blades were associated with shorter TTV in normal and difficult infant airway situations. The higher FPAs of hyperangulated blades in DA may avoid desaturations and decrease adverse events in pediatric airway management.
引用
收藏
页数:9
相关论文
共 25 条
[1]   Videolaryngoscopy in Neonates, Infants, and Children [J].
Balaban, Onur ;
Tobias, Joseph D. .
PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (05) :477-485
[2]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[3]   Videolaryngoscopy Versus Direct Laryngoscopy in Simulated Pediatric Intubation [J].
Donoghue, Aaron J. ;
Ades, Anne M. ;
Nishisaki, Akira ;
Deutsch, Ellen S. .
ANNALS OF EMERGENCY MEDICINE, 2013, 61 (03) :271-277
[4]   A Prospective Randomized Equivalence Trial of the GlideScope Cobalt® Video Laryngoscope to Traditional Direct Laryngoscopy in Neonates and Infants [J].
Fiadjoe, John E. ;
Gurnaney, Harshad ;
Dalesio, Nicholas ;
Sussman, Emily ;
Zhao, Huaqing ;
Zhang, Xuemei ;
Stricker, Paul A. .
ANESTHESIOLOGY, 2012, 116 (03) :622-628
[5]   Airway management complications in children with difficult tracheal intubation from the Pediatric Difficult Intubation (PeDI) registry: a prospective cohort analysis [J].
Fiadjoe, John Edem ;
Nishisaki, Akira ;
Jagannathan, Narasimhan ;
Hunyady, Agnes I. ;
Greenberg, Robert S. ;
Reynolds, Paul I. ;
Matuszczak, Maria E. ;
Rehman, Mohamed A. ;
Polaner, David M. ;
Szmuk, Peter ;
Nadkarni, Vinay M. ;
McGowan, Francis X., Jr. ;
Litman, Ronald S. ;
Kovatsis, Pete G. .
LANCET RESPIRATORY MEDICINE, 2016, 4 (01) :37-48
[6]   A Randomized Comparison of the GlideScope Videolaryngoscope to the Standard Laryngoscopy for Intubation by Pediatric Residents in Simulated Easy and Difficult Infant Airway Scenarios [J].
Fonte, Miguel ;
Oulego-Erroz, Ignacio ;
Nadkarni, Lindsay ;
Sanchez-Santos, Luis ;
Iglesias-Vasquez, Antonio ;
Rodriguez-Nunez, Antonio .
PEDIATRIC EMERGENCY CARE, 2011, 27 (05) :398-402
[7]   Incidence and associated factors of difficult tracheal intubations in pediatric ICUs: a report from National Emergency Airway Registry for Children: NEAR4KIDS [J].
Graciano, Ana Lia ;
Tamburro, Robert ;
Thompson, Ann E. ;
Fiadjoe, John ;
Nadkarni, Vinay M. ;
Nishisaki, Akira .
INTENSIVE CARE MEDICINE, 2014, 40 (11) :1659-1669
[8]   Incidence and predictors of difficult laryngoscopy in 11.219 pediatric anesthesia procedures [J].
Heinrich, Sebastian ;
Birkholz, Torsten ;
Ihmsen, Harald ;
Irouschek, Andrea ;
Ackermann, Andreas ;
Schmidt, Joachim .
PEDIATRIC ANESTHESIA, 2012, 22 (08) :729-736
[9]   A comparison of the Truview PCD and the GlideScope Cobalt AVL video-laryngoscopes to the Miller blade for successfully intubating manikins simulating normal and difficult pediatric airways [J].
Hippard, Helena K. ;
Kalyani, Govindan ;
Olutoye, Olutoyin A. ;
Mann, David G. ;
Watcha, Mehernoor F. .
PEDIATRIC ANESTHESIA, 2016, 26 (06) :613-620
[10]   Randomized equivalence trial of the King Vision aBlade videolaryngoscope with the Miller direct laryngoscope for routine tracheal intubation in children &lt;2 yr of age [J].
Jagannathan, N. ;
Hajduk, J. ;
Sohn, L. ;
Huang, A. ;
Sawardekar, A. ;
Albers, B. ;
Bienia, S. ;
De Oliveira, G. S. .
BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (06) :932-937