New method of thyratron ranging and diagnosis

被引:2
作者
Han, YJ [1 ]
Nam, SH
Park, SS
Lee, EW
机构
[1] POSTECH, Pohang Accelerator Lab, Pohang 790784, South Korea
[2] Kyungpook Natl Univ, Daegu 702701, South Korea
关键词
discharge; gas; high power; switch; thyratron;
D O I
10.1109/27.901215
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A thyratron is a very common switching device in many high-power pulse systems. However it is difficult to diagnose switching characteristics of the thyratron during its operation. A new diagnostic factor of the thyratron has been developed from a convection heat transfer theory, The new diagnostic factor is obtained from a dependence of a thyratron heater current on a thyratron internal gas pressure, We have verified theoretical proprieties of the diagnostic factor and confirmed experimentally that the assumption used in the theory is applicable to typical thyratrons. Using the diagnostic factor, we have designed and constructed an autoranging and autodiagnostic device for the thyratron.
引用
收藏
页码:1463 / 1468
页数:6
相关论文
共 4 条
[1]  
LECK JH, 1989, TOTAL PARTIAL PRESSU, P39
[2]  
NEAL RB, 1996, STANFORD 2 MILE ACCE, P444
[3]  
ROTH A, 1982, VACUUM-TECH, P37
[4]  
SHINTAKE T, P 18 INT C LIN GEN S, P184