Determination of metal ions by flow injection analysis with peroxyoxalate chemiluminescence detection

被引:18
|
作者
Sato, K
Tanaka, S
机构
[1] Department of Fundamental Science, College of Science and Engineering, Iwaki Mesei University, Iwaki-city
关键词
D O I
10.1006/mchj.1996.0013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis (F1A)/chemiluminescence detection has been used to the determination of Al(III), Zn(II), Cd(II), and In(III). Fluorescent compound which was formed by complexation of a metal ion and g-hydroxyquinoline was excited by the chemiluminescence reaction of bis(2,4,6-trichlorophenyl)oxalate and hydrogen peroxide. The chemiluminescence emission generated from the excited fluorescent compound was measured. The influences of the flow rate, pH, organic solvent and its concentration in mobile phase have been investigated. When 1,4-dioxane was used as an organic solvent, the highest chemiluminescence intensity was obtained at about pH 7. The detection limits for the metal ions were in the 20-70 ppb range. The simultaneous determination of the metal ions have further been attempted by the high-performance liquid chromatography (HPLC)I chemiluminescence method. (C) 1996 Academic Press, Inc.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 50 条
  • [1] Flow injection analysis of hydrogen peroxide with peroxyoxalate chemiluminescence detection
    Nabi, A
    Rashid, A
    Yaqoob, M
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1996, 18 (03): : 211 - 214
  • [2] Chemiluminescence detection of porphyrins with the peroxyoxalate reaction by flow-injection analysis
    Lin, M
    Huie, CW
    ANALYTICA CHIMICA ACTA, 1997, 339 (1-2) : 131 - 138
  • [3] Chemiluminescence detection of porphyrins with the peroxyoxalate reaction by flow-injection analysis
    Lin, M.
    Huie, C. W.
    Analytica Chimica Acta, 339 (1/2):
  • [4] Peroxyoxalate Photoinduced Chemiluminescence Detection of Norfloxacin in Pharmaceutical Products by Flow Injection Analysis
    Moreno-Gonzalez, David
    Garcia-Campana, Ana M.
    Gonzalez-Casado, Antonio
    ANALYTICAL LETTERS, 2010, 43 (15) : 2399 - 2410
  • [5] Enzymatic flow injection peroxyoxalate chemiluminescence determination of cholesterol in dairy products
    Feleke, Abisake
    Ho, Chu Ngi
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [6] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [7] Ethanol determination by the flow injection analysis, with chemiluminescence detection
    Danet, AF
    Badea, M
    Jipa, S
    REVISTA DE CHIMIE, 1997, 48 (08): : 726 - 731
  • [8] Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
    Li Liqing
    Lin, Guan
    Ming, Su
    Sun Hanwen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (06) : 356 - 362
  • [9] Determination of norfloxacin by flow injection analysis with chemiluminescence detection
    Sun, Han-wen
    Li, Li-qing
    Chen, Xue-yan
    Shi, Hong-mei
    Lue, Yun-kai
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (02): : 100 - 107
  • [10] Determination of riboflavin by flow injection analysis with chemiluminescence detection
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 5 Suppl (354):