Scleral Lens Sensor for Ocular Electrolyte Analysis

被引:41
|
作者
Yetisen, Ali K. [1 ]
Jiang, Nan [2 ]
Gonzalez, Carmen M. Castaneda [1 ]
Erenoglu, Zeynep Izlen [1 ]
Dong, Jie [1 ]
Dong, Xingchen [1 ]
Stoesser, Simon [1 ]
Brischwein, Martin [3 ]
Butt, Haider [4 ]
Cordeiro, Maria F. [5 ,6 ,7 ]
Jakobi, Martin [1 ]
Hayden, Oliver [3 ]
Koch, Alexander W. [1 ]
机构
[1] Tech Univ Munich, Inst Measurement Syst & Sensor Technol, D-80290 Munich, Germany
[2] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[3] Tech Univ Munich, Dept Elect & Comp Engn, TranslaTUM Campus, D-80290 Munich, Germany
[4] Khalifa Univ, Dept Mech Engn, Abu Dhabi 127788, U Arab Emirates
[5] Imperial Coll Healthcare NHS Trust, Western Eye Hosp, London NW1 5QH, England
[6] Imperial Coll, ICORG, London NW1 5QH, England
[7] UCL, Inst Ophthalmol, Dept Visual Neurosci, Glaucoma & Retinal Neurodegenerat Grp, London EC1V 9EL, England
关键词
biosensors; diagnostics; ophthalmology; scleral lenses; smartphones; DRY-EYE; TEAR FILM; CONTACT-LENS; LIPID LAYER; FLUORESCENT INDICATORS; CROWN-ETHERS; RISK-FACTORS; SURFACE; CORNEAL; DYSFUNCTION;
D O I
10.1002/adma.201906762
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The quantitative analysis of tear analytes in point-of-care settings can enable early diagnosis of ocular diseases. Here, a fluorescent scleral lens sensor is developed to quantitatively measure physiological levels of pH, Na+, K+, Ca2+, Mg2+, and Zn2+ ions. Benzenedicarboxylic acid, a pH probe, displays a sensitivity of 0.12 pH units within pH 7.0-8.0. Crown ether derivatives exhibit selectivity to Na+ and K+ ions within detection ranges of 0-100 and 0-50 mmol L-1, and selectivities of 15.6 and 8.1 mmol L-1, respectively. A 1,2 bis(o-aminophenoxy)ethane-N,N,-N',N'-tetraacetic-acid-based probe allows Ca2+ ion sensing with 0.02-0.05 mmol L-1 sensitivity within 0.50-1.25 mmol L-1 detection range. 5-Oxazolecarboxylic acid senses Mg2+ ions, exhibiting a sensitivity of 0.10-0.44 mmol L-1 within the range of 0.5-0.8 mmol L-1. The N-(2-methoxyphenyl)iminodiacetate Zn2+ ion sensor has a sensitivity of 1 mu mol L-1 within the range of 10-20 mu mol L-1. The fluorescent sensors are subsequently multiplexed in the concavities of an engraved scleral lens. A handheld ophthalmic readout device comprising light-emitting diodes (LEDs) and bandpass filters is fabricated to excite as well as read the scleral sensor. A smartphone camera application and an user interface are developed to deliver quantitative measurements with data deconvolution. The ophthalmic system enables the assessment of dry eye severity stages and the differentiation of its subtypes.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] SCLERAL LENS CLING MEASUREMENT
    MILLER, D
    CARROLL, JM
    HOLMBERG, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1968, 65 (06) : 929 - &
  • [42] Comparative analysis of outcomes of two (popular) techniques of haptic exteriorization in scleral fixation intra-ocular lens surgery - A retrospective study
    Baskaran, Prabu
    Srinivasan, Karthik
    Govindaraj, Indu
    Rajendran, Anand
    Rajamani, Archana
    Mahalingam, Maanasi
    Ramakrishnan, Seema
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (04) : 544 - 548
  • [43] On-eye breakage and recovery of mini-scleral contact lens without compromise for the ocular surface
    Macedo-de-Araujo, Rute J.
    van der Worp, Eef
    Gonzalez-Meijome, Jose M.
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (03): : 311 - 314
  • [44] Ocular hypertension after a triple procedure: Phacoemulsification, intraocular lens implantation, and scleral buckling surgery - Reply
    Girard, P
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1999, 19 (02): : 175 - 176
  • [45] Ocular Impression-Based Scleral Lens With Wavefront-Guided Optics for Visual Improvement in Keratoconus
    Gelles, John D.
    Cheung, Brian
    Akilov, Sarah
    Krisa, Sydney
    Trieu, Gina
    Greenstein, Steven A.
    Chung, Daniel
    Hersh, Peter S.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (11): : 485 - 488
  • [46] Effect of Scleral Lens Wear on Central Corneal Thickness and Intraocular Pressure in Patients With Ocular Surface Disease
    Shahnazi, Kevin C.
    Isozaki, Veronica L.
    Chiu, Gloria B.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (06): : 341 - 347
  • [47] Impact of scleral lens wear on ocular sensitivity, nerve fiber density and Langerhans cell density in keratoconus
    Lum, Edward
    Ng, Alan
    Sorbara, Luigina
    Murphy, Paul J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [48] STRESS UPON OCULAR COATS - EFFECTS OF SCLERAL CURVATURE SCLERAL THICKNESS AND INTRA-OCULAR PRESSURE
    FRIEDMAN, B
    EYE EAR NOSE AND THROAT MONTHLY, 1966, 45 (09): : 59 - &
  • [49] Microbiological Evaluation of Opened Saline Bottles for Scleral Lens Use and Hygiene Habits of Scleral Lens Patients
    Jeong, Moon
    Lee, Karen L.
    She, Rosemary C.
    Chiu, Gloria B.
    OPTOMETRY AND VISION SCIENCE, 2021, 98 (03) : 250 - 257
  • [50] Scleral Lenses and Ocular Cicatricial Pemphigoid
    Wiwanitkit, Viroj
    CORNEA, 2010, 29 (11) : 1330 - 1330