Scleral Lens Sensor for Ocular Electrolyte Analysis

被引:52
作者
Yetisen, Ali K. [1 ]
Jiang, Nan [2 ]
Gonzalez, Carmen M. Castaneda [1 ]
Erenoglu, Zeynep Izlen [1 ]
Dong, Jie [1 ]
Dong, Xingchen [1 ]
Stoesser, Simon [1 ]
Brischwein, Martin [3 ]
Butt, Haider [4 ]
Cordeiro, Maria F. [5 ,6 ,7 ]
Jakobi, Martin [1 ]
Hayden, Oliver [3 ]
Koch, Alexander W. [1 ]
机构
[1] Tech Univ Munich, Inst Measurement Syst & Sensor Technol, D-80290 Munich, Germany
[2] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[3] Tech Univ Munich, Dept Elect & Comp Engn, TranslaTUM Campus, D-80290 Munich, Germany
[4] Khalifa Univ, Dept Mech Engn, Abu Dhabi 127788, U Arab Emirates
[5] Imperial Coll Healthcare NHS Trust, Western Eye Hosp, London NW1 5QH, England
[6] Imperial Coll, ICORG, London NW1 5QH, England
[7] UCL, Inst Ophthalmol, Dept Visual Neurosci, Glaucoma & Retinal Neurodegenerat Grp, London EC1V 9EL, England
关键词
biosensors; diagnostics; ophthalmology; scleral lenses; smartphones; DRY-EYE; TEAR FILM; CONTACT-LENS; LIPID LAYER; FLUORESCENT INDICATORS; CROWN-ETHERS; RISK-FACTORS; SURFACE; CORNEAL; DYSFUNCTION;
D O I
10.1002/adma.201906762
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The quantitative analysis of tear analytes in point-of-care settings can enable early diagnosis of ocular diseases. Here, a fluorescent scleral lens sensor is developed to quantitatively measure physiological levels of pH, Na+, K+, Ca2+, Mg2+, and Zn2+ ions. Benzenedicarboxylic acid, a pH probe, displays a sensitivity of 0.12 pH units within pH 7.0-8.0. Crown ether derivatives exhibit selectivity to Na+ and K+ ions within detection ranges of 0-100 and 0-50 mmol L-1, and selectivities of 15.6 and 8.1 mmol L-1, respectively. A 1,2 bis(o-aminophenoxy)ethane-N,N,-N',N'-tetraacetic-acid-based probe allows Ca2+ ion sensing with 0.02-0.05 mmol L-1 sensitivity within 0.50-1.25 mmol L-1 detection range. 5-Oxazolecarboxylic acid senses Mg2+ ions, exhibiting a sensitivity of 0.10-0.44 mmol L-1 within the range of 0.5-0.8 mmol L-1. The N-(2-methoxyphenyl)iminodiacetate Zn2+ ion sensor has a sensitivity of 1 mu mol L-1 within the range of 10-20 mu mol L-1. The fluorescent sensors are subsequently multiplexed in the concavities of an engraved scleral lens. A handheld ophthalmic readout device comprising light-emitting diodes (LEDs) and bandpass filters is fabricated to excite as well as read the scleral sensor. A smartphone camera application and an user interface are developed to deliver quantitative measurements with data deconvolution. The ophthalmic system enables the assessment of dry eye severity stages and the differentiation of its subtypes.
引用
收藏
页数:17
相关论文
共 86 条
[1]   INTRACELLULAR NA+ MEASUREMENTS USING SODIUM GREEN TETRAACETATE WITH FLOW-CYTOMETRY [J].
AMORINO, GP ;
FOX, MH .
CYTOMETRY, 1995, 21 (03) :248-256
[2]   COMPARISON OF AQUEOUS-HUMOR AND SERUM ZINC LEVELS IN HUMANS [J].
ANDERSON, AR ;
KASTL, PR ;
KARCIOGLU, ZA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1987, 71 (03) :212-214
[3]   GENOTOXIC POTENTIAL OF CROWN ETHERS IN MAMMALIAN-CELLS - INDUCTION OF SISTER-CHROMATID EXCHANGES [J].
ARENAZ, P ;
BITTICKS, I ;
PANNELL, KH ;
GARCIA, S .
MUTATION RESEARCH, 1992, 280 (02) :109-115
[4]  
AVISAR R, 1977, INVEST OPHTH VIS SCI, V16, P1150
[5]   The comparison of efficacies of topical corticosteroids and nonsteroidal anti-inflammatory drops on dry eye patients: A clinical and immunocytochemical study [J].
Avunduk, AM ;
Avunduk, MC ;
Varnell, ED ;
Kaufman, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) :593-602
[6]  
Begley CG, 2002, ADV EXP MED BIOL, V506, P1009
[7]   Responses of contact lens wearers to a dry eye survey [J].
Begley, CG ;
Caffery, B ;
Nichols, KK ;
Chalmers, R .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (01) :40-46
[8]  
BERGMANSON JPG, 1995, OPHTHAL PHYSL OPT, V15, P83, DOI 10.1016/0275-5408(95)98237-H
[9]   TEAR SODIUM, POTASSIUM, CHLORIDE, AND CALCIUM AT VARIOUS FLOW-RATES - CHILDREN WITH CYSTIC-FIBROSIS AND UNAFFECTED SIBLINGS WITH AND WITHOUT CORNEAL STAINING [J].
BOTELHO, SY ;
GOLDSTEIN, AM ;
ROSENLUND, ML .
JOURNAL OF PEDIATRICS, 1973, 83 (04) :601-606
[10]   Grading of corneal and conjunctival staining in the context of other dry eye tests [J].
Bron, AJ ;
Evans, VE ;
Smith, JA .
CORNEA, 2003, 22 (07) :640-650