Spray characteristics determination of water mist for suppressing pool fire

被引:0
作者
Zheng, Li G. [1 ,2 ]
Yu, Ming G. [1 ]
Yu, Shui J. [1 ]
Liu, Zhi C. [1 ]
机构
[1] Henan Polytech Univ, Sch Safety Sci & Engn, Jiaozuo 454003, Henan, Peoples R China
[2] Zhejiang Univ, Inst Thermal Power Engn, Hangzhou 310027, Peoples R China
来源
MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS | 2007年 / 914卷
关键词
water mist; fire suppression; two-phase flow; measurement;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To optimize the design of a water mist fire suppression system or to provide input data and validation data for field models, the characteristics of the water mist field are needed. This data typically consists of the distribution of droplet sizes and velocities. In this research a LS2000 Laser Sizer has been proposed to simultaneously determine spray characteristics of 408 kinds of self-developed nozzles for fire suppression. The results of LS2000 Laser Sizer measurements to characterize the water mist produced by nozzles for suppressing pool fire are presented. These data can provide a foundation to the design and optimization of additive-containing WMFSS. To explore the effect of the water pressure on the droplet size distribution and spray velocity, data from three typical pressures of 0.9MPa, 1.2Mpa and I.5MPa have been obtained. With the measured average size and distribution of droplets, a comparison between three nozzles was made in the pressure of 1.5MPa to investigate the influence of the nozzle design parameters on atomizing characteristics. The results show that representative size of droplets decreases slightly and the water flow rate increases with the water pressure to the nozzle head P., and the droplet velocity of water mist is approximately directly proportional to P.. The trends that the nozzles with the larger D-32 have a wider range of droplet diameter distribution and their volume fraction curves shift towards the large diameter direction are also found in measurements. This will be favorable to the extinguishment of kerosene pool fire. The water flux density distribution results demonstrated that the water flux density over the cross section was very non-uniform when the water mist nozzle is improperly designed.
引用
收藏
页码:530 / +
页数:3
相关论文
共 12 条
  • [1] Fan Ming-hao, 2005, Journal of Zhejiang University, V39, P1431
  • [2] Fire suppression by water sprays
    Grant, G
    Brenton, J
    Drysdale, D
    [J]. PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2000, 26 (02) : 79 - 130
  • [3] DISCUSSIONS ON THE USE OF FINE WATER SPRAYS OR MISTS FOR FIRE SUPPRESSION
    JONES, A
    NOLAN, PF
    [J]. JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 1995, 8 (01) : 17 - 22
  • [4] LIU JH, 2000, LASER J, V21, P58
  • [5] MAWHINNEY JR, 1993, WAT MIST FIR SUPPR W, P37
  • [6] PUTORTI AD, 2004, THESIS U MICHIGAN GA
  • [7] PUTORTI AD, 1999, NATL I STAND TECHNOL
  • [8] Characterization of a non-isothermal water spray by global rainbow thermometry
    Vetrano, MR
    Gauthier, S
    van Beeck, J
    Boulet, P
    Buchlin, JM
    [J]. EXPERIMENTS IN FLUIDS, 2006, 40 (01) : 15 - 22
  • [9] [王喜世 Wang Xishi], 2003, [实验力学, Journal of Experimental Mechanics], V18, P6
  • [10] Non-intrusive measurements in fire sprinkler sprays
    Widmann, JF
    Sheppard, DT
    Lueptow, RM
    [J]. FIRE TECHNOLOGY, 2001, 37 (04) : 297 - 315