RBE-weighted dose in carbon ion therapy for ACC patients: Impact of the RBE model translation on treatment outcomes

被引:21
作者
Molinelli, Silvia [1 ]
Bonora, Maria [1 ]
Magro, Giuseppe [1 ]
Casale, Silvia [2 ]
Dale, Jon Espen [3 ]
Fossati, Piero [4 ]
Hasegawa, Azusa [5 ]
Mirandola, Alfredo [1 ]
Ronchi, Sara [1 ]
Russo, Stefania [1 ]
Preda, Lorenzo [1 ,6 ]
Valvo, Francesca [1 ]
Orecchia, Roberto [1 ,7 ]
Ciocca, Mario [1 ]
Vischioni, Barbara [1 ]
机构
[1] Natl Ctr Oncol Hadrontherapy CNAO, Clin Dept, Pavia, Italy
[2] IRCCS San Matteo Univ Hosp Fdn, Inst Radiol, Dept Diagnost Med, Pavia, Italy
[3] Haukeland Hosp, Dept Oncol & Med Phys, Bergen, Norway
[4] MedAustron Ion Therapy Ctr, Wiener Neustadt, Austria
[5] Osaka Heavy Ion Therapy Ctr, Osaka, Japan
[6] Univ Pavia, Dept Clin Surg Diagnost & Paediat Sci, Pavia, Italy
[7] European Inst Oncol, Milan, Italy
关键词
Carbon ion therapy; Relative biological effectiveness modeling; Adenoid cystic carcinoma; ADENOID CYSTIC CARCINOMA; RADIATION-THERAPY; RADIOTHERAPY; HEAD; LEM; PRESCRIPTION; IRRADIATION; SYSTEM; BEAMS; HIMAC;
D O I
10.1016/j.radonc.2019.08.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose/objective: The purpose of this study is to assess the impact of the conversion scheme for relative biological effectiveness (RBE)-weighted dose (D-RBE), implemented at our center, on treatment outcomes of adenoid cystic carcinoma (ACC) patients. Material/methods: Treatment plans of 78 ACC patients, optimized with the Local Effect Model (LEM), were recalculated with the modified Microdosimetric Kinetic Model (mMKM). D-RBE to 95%, 50% and 2% (D-V%) of the clinical target volume (CTV), were selected as relevant parameters to compare LEM and mMKM D-RBE. The pattern of failure of ACC treatments was analyzed in relation to uncertainties involved in the D-RBE translation methodology. Results: mMKM recalculations of LEM plans, optimized to a prescription dose of 68.8 Gy(RBE), showed a D-50% 8% higher, on average, than the expected value (60.8 Gy(RBE)), closer to the most frequently used mMKM prescription D-RBE (64 Gy(RBE)). D-95% and D-2% deviations, with respect to the optimization goals in the two RBE systems, increased of 0.5% and 14.2%, respectively, due to the steeper mMKM RBE variation along the beam path. Local recurrences were mainly (63%) reported in areas where CTV coverage was not satisfactory in the original LEM plan and the mMKM analysis showed that OARs constraints were too conservative. Conclusion: No case of local recurrence could be explained by inadequate mMKM target coverage that was not already present in the LEM plan. New constraints have been defined for optic pathways and brainstem to improve target coverage with no expected increase in tissue complications. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 25 条
[21]   How LEM-based RBE and dose-averaged LET affected clinical outcomes of sacral chordoma patients treated with carbon ion radiotherapy [J].
Molinelli, Silvia ;
Magro, Giuseppe ;
Mairani, Andrea ;
Allajbej, Albina ;
Mirandola, Alfredo ;
Chalaszczyk, Agnieszka ;
Imparato, Sara ;
Ciocca, Mario ;
Fiore, Maria Rosaria ;
Orlandi, Ester .
RADIOTHERAPY AND ONCOLOGY, 2021, 163 :209-214
[22]   Rectum Dose Constraints for Carbon Ion Therapy: Relative Biological Effectiveness Model Dependence in Relation to Clinical Outcomes [J].
Choi, Kyungdon ;
Molinelli, Silvia ;
Russo, Stefania ;
Mirandola, Alfredo ;
Fiore, Maria Rosaria ;
Vischioni, Barbara ;
Fossati, Piero ;
Petrucci, Rachele ;
Turturici, Irene ;
Dale, Jon Espen ;
Valvo, Francesca ;
Ciocca, Mario ;
Mairani, Andrea .
CANCERS, 2020, 12 (01)
[23]   The impact of interfractional anatomical changes on the accumulated dose in carbon ion therapy of pancreatic cancer patients [J].
Houweling, Antonetta C. ;
Fukata, Kyohei ;
Kubota, Yoshiki ;
Shimada, Hirofumi ;
Rasch, Coen R. N. ;
Ohno, Tatsuya ;
Bel, Arjan ;
van der Horst, Astrid .
RADIOTHERAPY AND ONCOLOGY, 2016, 119 (02) :319-325
[24]   Evaluation of patient positional reproducibility on the treatment couch and its impact on dose distribution using rotating gantry system in scanned carbon-ion beam therapy [J].
Kanai, Takayuki ;
Furuichi, Wataru ;
Mori, Shinichiro .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 :160-168
[25]   Retrospective comparison of rectal toxicity between carbon-ion radiotherapy and intensity-modulated radiation therapy based on treatment plan, normal tissue complication probability model, and clinical outcomes in prostate cancer [J].
Fukata, Kyohei ;
Kawamura, Hidemasa ;
Kubo, Nobuteru ;
Kanai, Tatsuaki ;
Torikoshi, Masami ;
Nakano, Takashi ;
Tashiro, Mutsumi ;
Ohno, Tatsuya .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 90 :6-12