An in vivo study to compare a plasma arc light and a conventional quartz halogen curing light in orthodontic bonding

被引:21
作者
Pettemerides, AP
Sherriff, M
Ireland, AJ [1 ]
机构
[1] Royal United Hosp, Dept Orthodont, Bath BA1 3NG, Avon, England
[2] Edgar Bldg Dent Practice, Bath, Avon, England
[3] GKT Dent Inst, Dept Dent Biomat Sci, London, England
关键词
D O I
10.1093/ejo/26.6.573
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the effectiveness of a plasma arc lamp with a conventional tungsten quartz halogen lamp in orthodontic bonding. Twenty consecutive patients had their brackets bonded either with Transbond XT (n = 10) or Fuji Ortho LC (n = 10). In total, 352 teeth were bonded, 176 in each group. Using a randomized cross-mouth control study design, where diagonally opposite quadrants were assigned a particular treatment, the bonds were then either cured with the control light, namely a halogen lamp, or a plasma arc lamp. The halogen light was used for 20 seconds per tooth and the plasma arc lamp for 3 seconds per tooth. The measurement parameter used was bond failure and the patients were monitored for a period of 6 months following initial bond placement. In the Transbond XT group, the proportion of bond failures was 3.41 per cent for both the halogen and the plasma arc lamp. For the Fuji Ortho LC group, the proportions were 11.4 and 10.2 per cent, respectively. No difference was observed with respect to in-service bond failure proportions between bonds cured with the plasma arc or the conventional halogen lamp, irrespective of the bonding agent. Use of the plasma arc lamp could therefore lead to considerable savings in clinical time. However, this must be weighed against the increased purchase price of the plasma arc lamp.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 20 条
[1]   An in vivo investigation into the use of resin-modified glass poly(alkenoate) cements as orthodontic bonding agents [J].
Choo, SC ;
Ireland, AJ ;
Sherriff, M .
EUROPEAN JOURNAL OF ORTHODONTICS, 2001, 23 (04) :403-409
[2]  
Frost T, 1997, Br J Orthod, V24, P35
[3]   Orthodontic bracket bonding with a plasma-arc light and resin-reinforced glass ionomer cement [J].
Ishikawa, H ;
Komori, A ;
Kojima, I ;
Ando, F .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 120 (01) :58-63
[4]   Plasma arc curing lights for orthodontic bonding [J].
Klocke, A ;
Korbmacher, HM ;
Huck, LG ;
Kahl-Nieke, B .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (06) :643-648
[5]  
Kurchak M, 1997, J Clin Orthod, V31, P371
[6]  
Loney RW, 2001, OPER DENT, V26, P516
[7]   Effect of curing with a plasma light on the properties of polymerizable dental restorative materials [J].
Millar, BJ ;
Nicholson, JW .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (06) :549-552
[8]  
MIZRAHI E, 1982, ANGLE ORTHOD, V52, P113
[10]   Rapid curing of bonding composite with a xenon plasma arc light [J].
Oesterle, LJ ;
Newman, SM ;
Shellhart, WC .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (06) :610-616