Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

被引:44
作者
Klasen, J. [1 ]
Blondin, D. [1 ]
Schmitt, P. [2 ]
Bi, X. [3 ]
Sansone, R. [4 ]
Wittsack, H. -J. [1 ]
Kroepil, P. [1 ]
Quentin, M. [1 ]
Kuhlemann, J. [1 ]
Miese, F. [1 ]
Heiss, C. [4 ]
Kelm, M. [4 ]
Antoch, G. [1 ]
Lanzman, R. S. [1 ]
机构
[1] Univ Dusseldorf, Dept Diagnost & Intervent Radiol, Fac Med, D-40225 Dusseldorf, Germany
[2] Siemens AG, Healthcare Sect, Erlangen, Germany
[3] Siemens Healthcare, Chicago, IL USA
[4] Univ Dusseldorf, Dept Cardiol, Fac Med, D-40225 Dusseldorf, Germany
关键词
MAGNETIC-RESONANCE ANGIOGRAPHY; PERIPHERAL ARTERIAL-DISEASE; OCCLUSIVE DISEASE; VASCULAR-DISEASE; PHASE-CONTRAST; ACCURACY;
D O I
10.1016/j.crad.2011.10.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. MATERIALS AND METHODS: Twenty-seven patients (mean age 66.6 +/- 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. RESULTS: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (>= 50%). CONCLUSION: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 446
页数:6
相关论文
共 24 条
[1]  
[Anonymous], 2011, ROFO FORTSCHR RONTG, V182, P861
[2]   PERIPHERAL VASCULAR-SURGERY WITH MAGNETIC-RESONANCE ANGIOGRAPHY AS THE SOLE PREOPERATIVE IMAGING MODALITY [J].
CARPENTER, JP ;
BAUM, RA ;
HOLLAND, GA ;
BARKER, CF ;
WILKERSON, D ;
ODONNELL, TF ;
BERKOWITZ, HD ;
RICOTTA, JR .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (06) :861-871
[3]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[4]   Quiescent-Interval Single-Shot Unenhanced Magnetic Resonance Angiography of Peripheral Vascular Disease: Technical Considerations and Clinical Feasibility [J].
Edelman, Robert R. ;
Sheehan, John J. ;
Dunkle, Eugene ;
Schindler, Nancy ;
Carr, James ;
Koktzoglou, Ioannis .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) :951-958
[5]   Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA [J].
Haneder, Stefan ;
Attenberger, Ulrike I. ;
Riffel, Philipp ;
Henzler, Thomas ;
Schoenberg, Stefan O. ;
Michaely, Henrik J. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1452-1461
[6]   Peripheral arterial disease detection, awareness, and treatment in primary care [J].
Hirsch, AT ;
Criqui, MH ;
Treat-Jacobson, D ;
Regensteiner, JG ;
Creager, MA ;
Olin, JW ;
Krook, SH ;
Hunninghake, DB ;
Comerota, AJ ;
Walsh, ME ;
McDermott, MM ;
Hiatt, WR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (11) :1317-1324
[7]   Evaluation of Peripheral Arterial Disease with Nonenhanced Quiescent-Interval Single-Shot MR Angiography [J].
Hodnett, Philip A. ;
Koktzoglou, Ioannis ;
Davarpanah, Amir H. ;
Scanlon, Timothy G. ;
Collins, Jeremy D. ;
Sheehan, John J. ;
Dunkle, Eugene E. ;
Gupta, Navyash ;
Carr, James C. ;
Edelman, Robert R. .
RADIOLOGY, 2011, 260 (01) :282-293
[8]   Nonenhanced MR Angiography Techniques [J].
Lanzman, R. S. ;
Schmitt, P. ;
Kroepill, P. ;
Blondinl, D. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (10) :913-924
[9]   Unenhanced calf MR angiography at 3.0 T using electrocardiography-gated partial-fourier fast spin echo imaging with variable flip angle [J].
Li, Dan ;
Lin, Jiang ;
Yan, Fuhua ;
Wu, Qingyuan ;
Lv, Weiwei ;
San, Yan ;
Yun, Hong .
EUROPEAN RADIOLOGY, 2011, 21 (06) :1311-1322
[10]   3D nongadolinium-enhanced ECG-gated MRA of the distal lower extremities: Preliminary clinical experience [J].
Lim, Ruth P. ;
Hecht, Elizabeth M. ;
Xu, Jian ;
Babb, James S. ;
Oesingmann, Niels ;
Wong, Samson ;
Muhs, Bart E. ;
Gagne, Paul ;
Lee, Vivian S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :181-189