Analyzing cell mechanics in hematologic diseases with microfluidic biophysical flow cytometry

被引:219
作者
Rosenbluth, Michael J. [1 ,2 ]
Lam, Wilbur A. [1 ,2 ,3 ]
Fletcher, Daniel A. [1 ,2 ,4 ]
机构
[1] Dept Bioengn, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Univ Calif San Francisco, Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[3] Univ Calif San Francisco, Dept Pediat, Div Pediat Hematol Oncol, San Francisco, CA 94143 USA
[4] Univ Calif Berkeley, Biophys Grad Grp, Berkeley, CA 94720 USA
关键词
D O I
10.1039/b802931h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pathological processes in hematologic diseases originate at the single-cell level, often making measurements on individual cells more clinically relevant than population averages from bulk analysis. For this reason, flow cytometry has been an effective tool for single-cell analysis of properties using light scattering and fluorescence labeling. However, conventional flow cytometry cannot measure cell mechanical properties, alterations of which contribute to the pathophysiology of hematologic diseases such as sepsis, diabetic retinopathy, and sickle cell anemia. Here we present a high-throughput microfluidics-based 'biophysical' flow cytometry technique that measures single-cell transit times of blood cell populations passing through in vitro capillary networks. To demonstrate clinical relevance, we use this technique to characterize biophysical changes in two model disease states in which mechanical properties of cells are thought to lead to microvascular obstruction: (i) sepsis, a process in which inflammatory mediators in the bloodstream activate neutrophils and (ii) leukostasis, an often fatal and poorly understood complication of acute leukemia. Using patient samples, we show that cell transit time through and occlusion of microfluidic channels is increased for both disease states compared to control samples, and we find that mechanical heterogeneity of blood cell populations is a better predictor of microvascular obstruction than average properties. Inflammatory mediators involved in sepsis were observed to significantly affect the shape and magnitude of the neutrophil transit time population distribution. Altered properties of leukemia cell subpopulations, rather than of the population as a whole, were found to correlate with symptoms of leukostasis in patients-a new result that may be useful for guiding leukemia therapy. By treating cells with drugs that affect the cytoskeleton, we also demonstrate that their transit times could be significantly reduced. Biophysical flow cytometry offers a low-cost and high-throughput diagnostic and drug discovery platform for hematologic diseases that affect microcirculatory flow.
引用
收藏
页码:1062 / 1070
页数:9
相关论文
共 70 条
  • [1] High-speed microfluidic differential manometer for cellular-scale hydrodynamics
    Abkarian, M
    Faivre, M
    Stone, HA
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (03) : 538 - 542
  • [2] Metastable polymerization of sickle hemoglobin in droplets
    Aprelev, Alexey
    Weng, Weijun
    Zakharov, Mikhail
    Rotter, Maria
    Yosmanovich, Donna
    Kwong, Suzanna
    Briehl, Robin W.
    Ferrone, Frank A.
    [J]. JOURNAL OF MOLECULAR BIOLOGY, 2007, 369 (05) : 1170 - 1174
  • [3] EFFECT OF PENTOXIFYLLINE ON THE FLOW OF POLYMORPHONUCLEAR LEUKOCYTES THROUGH A MODEL CAPILLARY
    ARMSTRONG, M
    NEEDHAM, D
    HATCHELL, DL
    NUNN, RS
    [J]. ANGIOLOGY, 1990, 41 (04) : 253 - 262
  • [4] WHITE BLOOD-CELL DEFORMABILITY AND PLUGGING OF SKELETAL-MUSCLE CAPILLARIES IN HEMORRHAGIC-SHOCK
    BAGGE, U
    AMUNDSON, B
    LAURITZEN, C
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1980, 108 (02): : 159 - 163
  • [5] Neutrophil transit times through pulmonary capillaries: The effects of capillary geometry and fMLP-stimulation
    Bathe, M
    Shirai, A
    Doerschuk, CM
    Kamm, RD
    [J]. BIOPHYSICAL JOURNAL, 2002, 83 (04) : 1917 - 1933
  • [6] Physics and applications of microfluidics in biology
    Beebe, DJ
    Mensing, GA
    Walker, GM
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 : 261 - 286
  • [7] THE EFFECT OF ENDOTOXIN AND TUMOR-NECROSIS-FACTOR ON ERYTHROCYTE AND LEUKOCYTE DEFORMABILITY INVITRO
    BETTICHER, DC
    KELLER, H
    MALY, FE
    REINHART, WH
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1993, 83 (01) : 130 - 137
  • [8] An automated cell analysis sensing system based on a microfabricated rheoscope for the study of red blood cells physiology
    Bransky, Avishay
    Korin, Natanel
    Nemirovski, Yael
    Dinnar, Uri
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 22 (02) : 165 - 169
  • [9] RHEOLOGICAL RESPONSE OF NEUTROPHILS TO DIFFERENT TYPES OF STIMULATION
    BUTTRUM, SM
    DROST, EM
    MACNEE, W
    GOFFIN, E
    LOCKWOOD, CM
    HATTON, R
    NASH, GB
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (04) : 1801 - 1810
  • [10] Self-sorting of white blood cells in a lattice
    Carlson, RH
    Gabel, CV
    Chan, SS
    Austin, RH
    Brody, JP
    Winkelman, JW
    [J]. PHYSICAL REVIEW LETTERS, 1997, 79 (11) : 2149 - 2152