Optimizing a chromatographic three component separation: A comparison of mechanistic and empiric modeling approaches

被引:50
作者
Osberghaus, A. [1 ]
Hepbildikler, S. [2 ]
Nath, S. [2 ]
Haindl, M. [2 ]
von Lieres, E. [3 ]
Hubbuch, J. [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Sect Biomol Separat Engn 4, D-76131 Karlsruhe, Germany
[2] Roche Diagnost GmbH, Pharmaceut Biotech Prod, D-82377 Penzberg, Germany
[3] Res Ctr Julich, Inst Bio & Geosci 1, D-52425 Julich, Germany
关键词
Ion exchange chromatography; Design of experiments; Response surface modeling; Mechanistic modeling; Steric mass action (SMA); Separation optimization; ION-EXCHANGE CHROMATOGRAPHY; OPTIMAL ONION DESIGNS; LIQUID-CHROMATOGRAPHY; RETENTION MODELS; GRADIENT ELUTION; OPTIMIZATION; MULTIVARIATE; ADSORPTION; PREDICTION; SIMULATION;
D O I
10.1016/j.chroma.2012.03.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The search for a favorable and robust operating point of a separation process represents a complex multi-factor optimization problem. This problem is typically tackled by design of experiments (DoE) in the factor space and empiric response surface modeling (RSM); however, separation optimizations based on mechanistic modeling are on the rise. In this paper, a DoE-RSM-approach and a mechanistic modeling approach are compared with respect to their performance and predictive power by means of a case study - the optimization of a multicomponent separation of proteins in an ion exchange chromatography step with a nonlinear gradient (ribonuclease A, cytochrome c and lysozyme on SP Sepharose FF). The results revealed that at least for complex problems with low robustness, the performance of the DoE-approach is significantly inferior to the performance of the mechanistic model. While some influential factors of the system could be detected with the DoE-RSM-approach, predictions concerning the peak resolutions were mostly inaccurate and the optimization failed. The predictions of the mechanistic model for separation results were very accurate. Influences of the experimental factors could be quantified and the separation was optimized with respect to several objectives. However, the discussion of advantages and disadvantages of empiric and mechanistic modeling generates synergies of both methods and leads to a new optimization concept, which is promising with respect to an efficient employment of high throughput screening data. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 95
页数:10
相关论文
共 41 条
[1]  
[Anonymous], 2004, PAT FRAM INN PHARM
[2]   OPTIMIZATION IN PHOTOCHEMICAL-REACTION DETECTION - APPLICATION TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PHOTOLYSIS ELECTROCHEMICAL DETECTION [J].
BACHMAN, WJ ;
STEWART, JT .
JOURNAL OF CHROMATOGRAPHY, 1989, 481 :121-133
[3]   A MULTIVARIATE OPTIMIZATION OF TRIACYGLYCEROL ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BERGQVIST, MHJ ;
KAUFMANN, P .
LIPIDS, 1993, 28 (07) :667-675
[4]   SIMPLEX OPTIMIZATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS [J].
BERRIDGE, JC .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :3-14
[5]   Application of Different Artificial Neural Networks Retention Models for Multi-Criteria Decision-Making Optimization in Gradient Ion Chromatography [J].
Bolanca, Tomislav ;
Cerjan-Stefanovic, Stefica ;
Lusa, Melita ;
Ukic, Sime ;
Rogosic, Marko .
SEPARATION SCIENCE AND TECHNOLOGY, 2010, 45 (02) :236-243
[6]   pH dependence of ion-exchange equilibrium of proteins [J].
Bosma, JC ;
Wesselingh, JA .
AICHE JOURNAL, 1998, 44 (11) :2399-2409
[7]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[8]   Optimisation of chromatographic separations by use of a chromatographic response function, empirical modelling and multivariate analysis [J].
Bylund, D ;
Bergens, A ;
Jacobsson, SP .
CHROMATOGRAPHIA, 1997, 44 (1-2) :74-80
[9]   A systematic approach for modeling chromatographic processes - Application to protein purification [J].
Chan, Sharon ;
Titchener-Hooker, Nigel ;
Bracewell, Daniel G. ;
Sorensen, Eva .
AICHE JOURNAL, 2008, 54 (04) :965-977
[10]   Statistical designs and response surface techniques for the optimization of chromatographic systems [J].
Costa Ferreira, Sergio Luis ;
Bruns, Roy Edward ;
Paranhos da Silva, Erik Galvao ;
Lopes dos Santos, Walter Nei ;
Quintella, Cristina Maria ;
David, Jorge Mauricio ;
Bittencourt de Andrade, Jailson ;
Breitkreitz, Marcia Cristina ;
Sales Fontes Jardim, Isabel Cristina ;
Barros Neto, Benicio .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1158 (1-2) :2-14